User manual HONEYWELL HVAC03C5

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL HVAC03C5. We hope that this HONEYWELL HVAC03C5 user guide will be useful to you.


HONEYWELL HVAC03C5 : Download the complete user guide (1163 Ko)

Manual abstract: user guide HONEYWELL HVAC03C5

Detailed instructions for use are in the User's Guide.

[. . . ] HVAC03C2 ­ HVAC61C2 HVAC03C5 ­ HVAC61C5 NXL HVAC INVERTERS PRODUCT DATA SPECIFICATIONS Mains Connection Input voltage Uin Input Frequency Connection to mains 380. . . 500 Vac (±10%), 3~ 45. . . 66 Hz Once per minute or less Motor Connection Output voltage 0 - Uin Continuous output current: Low overload IL: Ambient peak temperature (for Fan/Pump) max. +45°C (with 24h average ambient +40°C), overload 1. 1 x IL (1min/10min) Starting Torque: Low overload 150% (for Fan/Pump) GENERAL These variable frequency drives provide step-less speed control for all basic HVAC applications: · Pumps · Fans · Compressors Starting Current Output Frequency Frequency resolution 2 x IH 2s/20s 0. . . 320 Hz 0. 01 Hz Control Characteristics Control Method Frequency Control U/f, Open Loop Sensorless Vector Control 1. . . 16 kHz; default 6 kHz (no derating) Resolution 0. 1% (10 bit), accuracy ±1% Resolution 0. 01 Hz 30. . . 320 Hz 0. 1. . . 3000 sec 0. 1. . . 3000 sec DC-brake: 30%*TN (without brake option) FEATURES · · · · · · · · · · · Most compact size in the market (especially IP54) Integrated RFI-filters and AC-chokes Credit card size "Quick Guide" for installation and commissioning attached to every unit 30s Start-Up Wizard HVAC-optimized software Easy "keypad ­ remote" change with 1 button Trip free operation with safety switch Silent motor operation with 6 kHz switching frequency Overtemperature ride-through Power ride-through Integrated PID controller · Normal and Inverse regulation · Sleep Mode · Anti-Windup function Integrated Pump/Fan Cascade Controller Switching Frequency Frequency reference: Analogue input Keypad reference Field Weakening point Acceleration time Deceleration time Braking torque · ® U. S. [. . . ] Product Identification Code 3 EN0B-0619GE51 R1107 NXL HVAC VARIABLE FREQUENCY DRIVES HONEYWELL EMC CLASSES AND MARKET REQUIREMENTS Fig. EMC classes in practice 1 2 3 4 5 6 EMC levels C H L T Hospital O R Airport O R Residential Area Commercial Light Industry Area Heavy Industry R R O R O R R (IT Network) O = optional, R = required C= H= L= T= EN61800-3 [2004] Category C1 (standard in IP54 units) EN61800-3 [2004] Category C2 (standard in IP21 units) EN61800-3 [2004] industrial requirements fulfilled (standard in Honeywell inverters >160kW) EN61800-3 [2004] IT network (e. g. ships) requirements fulfilled, units can be easily converted to Tclass from standard EMC class. Instructions for this can be found from NXL HVAC User's Manual which can be downloaded from http://inettrack. europe. honeywell. com/support/ EN0B-0619GE51 R1107 4 NXL HVAC VARIABLE FREQUENCY DRIVES MECHANICAL DIMENSIONS AND MOUNTING The frequency converter shall be fixed with four screws (or bolts, depending on the unit size). Ø Ø W2 W2 D1 D1 H1 H2 H1 H2 H3 W1 W1 E1Ø E1Ø H3 E2Ø* E2Ø* Ø Ø fr5ip21. fh8 fr5ip21. fh8 Fig. NXL HVAC dimensions Type MF4 (HVAC03-12) MF5 (HVAC16-31) MF6 (HVAC38-61) W1 128 144 195 W2 100 100 148 H1 327 419 558 H2 313 406 541 Dimensions H3 D1 292 190 391 214 519 237 7 7 9 E1 3 x 28. 3 2 x 37 3 x 37 E2* 1 x 28. 3 Enough free space shall be left above and below the frequency converter to ensure sufficient air circulation and cooling. You will find the required dimensions for free space in the table below. C Type MF4 (HVAC03-12) MF5 (HVAC16-31) MF6 (HVAC38-61) B B A 20 20 30 Dimensions [mm] B C 20 100 20 120 20 160 D 50 60 80 A A A B C D = clearance around the freq. converter (see also B) = distance from one frequency converter to another or distance to cabinet wall = free space above the frequency converter = free space underneath the frequency converter D NK5_2 Fig. NXL HVAC installation space 5 EN0B-0619GE51 R1107 NXL HVAC VARIABLE FREQUENCY DRIVES REQUIRED COOLING AIR Type MF4 (HVAC03-12) MF5 (HVAC16-31) MF6 (HVAC38-61) Cooling air required [m3/h) 70 190 425 CABLING B- B+ RL1 L2 L3 U/T1 V/T2 W/T3 nxlk58. fh8 Fig. NXL HVAC power connections Use cables with heat resistance of at least +70°C. The cables and the fuses must be dimensioned according to the tables below. These instructions apply only to cases with one motor and one cable connection from the frequency converter to the motor. In any other case, ask the technical support for more information. Connection Mains cable Cable type Power cable intended for fixed installation and the specific mains voltage. [. . . ] Relay 1 NO (run) Thermistor Input; Rtrip = 4. 7 k1 (PTC) 7 EN0B-0619GE51 R1107 NXL HVAC VARIABLE FREQUENCY DRIVES FEATURES / FUNCTIONS · Easy to set-up features 30 second start-up wizard VFD programming in just 4 easy steps: 1. Tune the motor nominal current - RESULT: Fully configured drive ready to accept 0-10 V analogue speed signal from controller in 30 seconds! Quick installation guide Includes 1-page instructions for installation & set-up All the essential information on installation and basic commissioning on 1 paper Attached to every product "Keypad ­ Remote" Operation Single button operation to change the control to manual (keypad) and back Useful function when commissioning and testing HVAC applications. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL HVAC03C5




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL HVAC03C5 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.