User manual HONEYWELL HCW 82 INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL HCW 82. We hope that this HONEYWELL HCW 82 user guide will be useful to you.


HONEYWELL HCW 82 INSTALLATION: Download the complete user guide (1194 Ko)

Manual abstract: user guide HONEYWELL HCW 82INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] The HCW 82/HCF 82 room devices are used for intelligent room temperature control. The room temperature sensor HCF 82 measures the room temperature and sends the measured values to other devices. The HCW 82 measures the room temperature and additionally allows the room setpoint temperature to be adjusted. [. . . ] In order to assign a temperature zone to the HCW 82/ HCF 82, follow the instructions from the chapter entitled "Start-up" in the "Underfloor heating controller HCE 80/HCE 80R/ HCC 80/HCC 80R" installation instructions. When selecting the operating site of each device ensure that the distance to radio devices such as radio headphones, cordless phones, etc. Do not install the devices over metallic wall connecting sockets and at least 30 cm away from the cover of the heat generator. Correct the installation site of the room temperature sensor if necessary. In order to assign a temperature zone to the HCW 82/ HCF 82, follow the instructions from the chapter entitled "Installing the HCW 82/HCF 82 and assigning it to a room" in the Hometronic Manager HCM 200D operating instructions. The HCW 82/HCF 82 can only be assigned to the Hometronic Manager as a frost protection sensor if the device switch HS 30 is used for the boiler request. Activate the teach-in function within 4 minutes by pressing the Send button at the room temperature sensor (see Fig. For information on how to read measured data of the room temperature sensor at the Hometronic Manager or adapt the threshold value for the frost protection function, please refer to the operating instructions of the Hometronic Manager. Operation with an external power source In addition to battery operation, the setpoint adjuster HCW 82 is also prepared for operation with an external power source. The room setpoint temperature can be set easily at the setpoint adjuster HCW 82 by means of an adjustment dial. Dispose of the batteries according to the local statutory requirements and not with the used domestic refuse. You can limit the setting range that can be used at the adjustment dial. Place the two small pins into the holes of the adjustment dials in order to limit the adjustment range (see Fig. 6, the pins are inserted so that the adjustment dial can only be adjusted by ±3 °C around the zero point. If appropriate, put the adjustment back in, rotated by 180° until it has the position shown. The maximum permissible cable length from the power supply unit to the device amounts to 100 m. [. . . ] The device is now in test mode and sends a test signal every 5 seconds. The test mode can also be terminated by removing the batteries, disconnecting the power supply or by pressing the teach-in button. Hereby declares that this device complies with the basic requirements and other relevant regulations of guideline 1999/5/EC. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL HCW 82




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL HCW 82 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.