User manual HONEYWELL HC60NG

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL HC60NG. We hope that this HONEYWELL HC60NG user guide will be useful to you.


HONEYWELL HC60NG : Download the complete user guide (2656 Ko)

You may also download the following manuals related to this product:

   HONEYWELL HC60NG DATASHEET (561 ko)

Manual abstract: user guide HONEYWELL HC60NG

Detailed instructions for use are in the User's Guide.

[. . . ] It can be used to control gas and oil boilers, a variety of valves and actuators or electrical heating systems. Because of the simple HCW 80 analogue user interface with absolute set point temperature scale, the room set point temperature can be easily adjusted. Follow the installation diagrams to install and connect the power supply to the relay module HC60NG. [. . . ] Do not install the devices over metallic wall connecting sockets and at least 30 cm away from the cover of the heat generator. The room unit HCW 80 can send a test signal to the assigned relay module HC60NG in order to test the signal strength. Keep the teach-in button of the HCW 80 pressed for at least 15 sec until the red LED of the HCW 80 is OFF. When the RF communication is lost for a period of 1 h, the red LED of the relay module HC60NG is ON to indicate that no RF messages have been received during the last hour. When RF communication is re-established the relay module HC60NG will automatically return to normal operation mode. The teach-in operation is required if the relay module HC60NG and the room unit HCW 80 are not pre-bound e. the resetting was successful when the red LED flashes rapidly (1/9 ON/OFF). After the factory reset the HC60NG looses the communication with the HCW 80. After the power up of the relay module HC60NG the red LED will start to flash at 0. If this is not the case set the HC60NG into the reset mode see section 7 "Factory reset of relay module HC60NG". The room set point temperature can be set easily at the set point adjuster by means of an adjustment dial. The room set point range is from 10 °C to 30 °C including the frost protection setting (5 °C). The HCW 80 simulates a mechanical thermostat by LED indication as follows: The red LED at the HCW 80 will be switched ON for 4 sec if the deviation between the set point and the room temperature is >1 °C. Place the two small pins into the holes of the adjustment dial in order to limit the adjustment range (see Fig. 16, the pins are inserted so that the adjustment dial can only be adjusted in the range of 19 °C to frost protection (lower limit) and 19 °C to 30 °C (higher limit) around the value 19 °C. If appropriate, put the adjustment back in, rotated by 180° until it has the position shown. [. . . ] From the rear (wall box mounting), right an bottom Do not dispose of the unit with the usual domestic refuse. Honeywell nu accept nici o responsabilitate pentru orice pierdere sau daun datorat oricrei erori sau omisiuni care ar putea fi coninut din neatenie în aceast schem. Hereby declares that this device complies with the basic requirements and other relevant regulations of guideline 1999/5/EC. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL HC60NG




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL HC60NG will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.