User manual HONEYWELL EXCEL 50

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL EXCEL 50. We hope that this HONEYWELL EXCEL 50 user guide will be useful to you.


HONEYWELL EXCEL 50 : Download the complete user guide (993 Ko)

You may also download the following manuals related to this product:

   HONEYWELL EXCEL 50 DATASHEET (473 ko)
   HONEYWELL EXCEL 50 INSTALLATION (1555 ko)
   HONEYWELL EXCEL 50 SOFTWARE DESCRIPTION (591 ko)
   HONEYWELL EXCEL 50 INTERFACE DESCRIPTION (695 ko)

Manual abstract: user guide HONEYWELL EXCEL 50

Detailed instructions for use are in the User's Guide.

[. . . ] Excel 50 CONTROLLER HONEYWELL EXCEL 5000 OPEN SYSTEM USER GUIDE ® U. S. · All rights reserved EN2B-0137GE51 R0109 EXCEL 50 USER GUIDE Trademark Information Echelon, LON, LONMARK, LONWORKS, LonBuilder, NodeBuilder, LonManager, LonTalk, LonUsers, LonPoint, Neuron, 3120, 3150, the Echelon logo, the LONMARK logo, and the LonUsers logo are trademarks of Echelon Corporation registered in the United States and other countries. LonLink, LonResponse, LonSupport, and LonMaker are trademarks of Echelon Corporation. EN2B-0137GE51 R0109 2 EXCEL 50 USER GUIDE CONTENTS Revision overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 About This User Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] C1<code> C3<code> C5<code> NEXT C2<code> C4<code> C6<code> This screen appears in configurable applications only. EN2B-0137GE51 R0109 37 DATA POINTS / PARAMETERS KEY EXCEL 50 USER GUIDE In this screen, the codes of the configurable application can be viewed. Applications with eight configuration codes have two on a second screen as shown below. C7<code> NEXT C8<code> This screen appears in configurable applications only. IMPORTANT After performing a RESET, all data in RAM and the configuration codes are lost. To change the codes perform a RESET (press the down arrow and the minus key simultaneously). 'NEXT' is preselected to move to the Tool Information screen. Data Name:<tool name> Vers:<version number> BACK NEXT This screen displays the name and version number of the tool used to create the current application. Data User Name: <user name> BACK NEXT This screen displays the user name for the tool used to create the current application. 'NEXT' is preselected to move to the 'User ID' screen. Confirm with ENTER. User ID: <user ID number> NEXT This screen displays the user license number for the tool used to create the current application. 'NEXT' is preselected to move to the Operating Sequence Revision screen. AMA: <revision number> ATX: <revision number> BACK This screen displays the revision numbers for the AMA and ATX files used to create the operating sequence. Asterisks will appear before and after the AMA revision number if the AMA or ADS files have been changed before the compilation. Asterisks will also appear before and after the ATX revision number if the ATX file has been changed before compilation. Confirm with ENTER. 38 EN2B-0137GE51 R0109 EXCEL 50 USER GUIDE DATA POINTS / PARAMETERS KEY Hardware Interface Configuration The following sequence will depend upon the specific hardware interfaces featured on the controller. The list box will contain a combination of the following options: Bport (serial port), C-bus, LON-bus, M-Bus, or Modem (RS232 serial port). HW-Interf. B-Port C-Bus 1 LON-Bus B-Port Using the arrow keys, move the cursor to the 'B-Port' field. Baudrate<bdrate> BACK Using the arrow keys, move the cursor to the value field. Using the arrow keys, move the cursor to `BACK' and confirm with ENTER. C-Bus Using the arrow keys, move the cursor to the 'C-Bus' field. Baudrate:<bdrate> Contr. No: 1 Bus ID BACK NOTE: If you set the bus ID to a non-zero value, the C-bus baudrate will be immediately disabled (i. e. NOTE: To provide compatibility with the PC-based XL-Online operator and service software, this C-Bus screen may appear even for controllers with application modules that do not have a C-Bus connection. This screen will not appear for controllers using the XD50E application module, which does not allow downloads. [. . . ] The user can, of course, recall the measured value coming from the attribute "Value", but this has no effect on the application program. Manual value Hours Run An hours run log can be carried out for digital data points (physical and pseudo), e. g. The accumulated hours run are displayed in the attribute "Hours Run". The corresponding values have a resolution of 1 minute. 62 EN2B-0137GE51 R0109 EXCEL 50 USER GUIDE ALARM DESCRIPTION Technical Address The Excel 50 controller has 22 physical inputs / outputs. Each physical data point has a fixed technical address containing information about the controller number, the board number, and the input / output number on the board. User Address The 14-character user address for each data point (physical and pseudo) can be displayed on the operator's terminal. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL EXCEL 50




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL EXCEL 50 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.