User manual HONEYWELL EXCEL 12

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL EXCEL 12. We hope that this HONEYWELL EXCEL 12 user guide will be useful to you.


HONEYWELL EXCEL 12 : Download the complete user guide (330 Ko)

You may also download the following manuals related to this product:

   HONEYWELL EXCEL 12 DATASHEET (949 ko)
   HONEYWELL EXCEL 12 GUIDE D INSTALLATION (881 ko)
   HONEYWELL EXCEL 12 FCU PLUS LIGHT DATASHEET (967 ko)
   HONEYWELL EXCEL 12 FCU PLUS 4 LIGHTS DATASHEET (951 ko)
   HONEYWELL EXCEL 12 FCU PLUS LIGHT PLUS SUNBLIND DATASHEET (1024 ko)

Manual abstract: user guide HONEYWELL EXCEL 12

Detailed instructions for use are in the User's Guide.

[. . . ] Excel 12 housing (side view) DIN Rail Mounting/Dismounting After mounting the unit onto the wall or ceiling, provide for cable access by snipping out the terminal protection covers' cut-out tabs and snap (by hand) the covers (available in packs of 8) into place onto the housing. 10 on page 7) and pry it loose. The unit can be mounted onto a DIN rail simply by snapping it into place and securing it with a stopper to prevent sliding. It is dismounted by gently pulling the stirrup located in the base of the housing (see Fig. 2). EYELETS FOR CABLE BINDERS SCREWING NOSE (round hole) Terminal Assignment The terminal blocks are arranged on two sides of the controller: the relay side and the low-voltage side. [. . . ] Configuration of the LED to Display Info on Overrides The wall module's LED can indicate if an override has been activated by either the wall module's bypass button being pushed or because the Excel 12 has received a network command. Specifically: If the wall module's LED is OFF, then no override (from the wall module or the LONWORKS network) is currently in effect. If the wall module's LED is ON continuously, the bypass button or a network command has placed the Excel 12 into the "occupied" or "bypass" mode (however, if the bypass button is again pushed or if a cancellation network command is received or if the bypass time expires, the Excel 12 will return to its scheduled occupancy mode). If the wall module's LED flashes once per second, the bypass button or a network command has placed the Excel 12 into the "unoccupied" mode (however, if the bypass button is again pushed or if a cancellation network command is received, the Excel 12 will return to its scheduled occupancy mode). If the wall module's LED flashes twice per second, a network command has placed the Excel 12 into either the "standby" or the "occupied" mode. and mean that the Excel 12 is OFF, but that "frost protection" has been enabled. IMPORTANT Do not bundle wires carrying field device signals or LonWorks communications together with high-voltage power supply or relay cables. IMPORTANT Try to avoid installing in areas of high electromagnetic noise (EMI). The unit must be wired to the LONWORKS network using level IV 22 AWG (Belden part number 9D220150) or plenum-rated level IV 22 AWG (Belden part number 9H2201504) nonshielded, twisted-pair, solid-conductor wire. When possible, use Honeywell AK3781, AK3782, AK3791, or AK3792 cable (US part nos. ). See Excel 50/5000 LonWorks Mechanisms, EN0B-0270GE51, for details, including max. 9 via terminal pins 3 and 4 (black screw-type T terminal plug) underneath the terminal protection cover (if present) located on the low-voltage side. Terminal 24 and 25 are used to connect further devices to the LONWORKS network. Connection of CO2-Sensor A CO2-sensor (e. g. C7110D1009) may be connected to analog inputs 1, 5, or 7 for air-quality control. W7704 TEMP. SENSOR BYPASS / FAN COMMON 9 10 11 12 13 14 15 16 24V ~ 22 24V 0 23 LON 1 24 LON 2 25 LED OUT 24 VAC CO2 IN Excel 12 24V ~ 24V 0 2 LON 1 3 LON 2 4 1 2 3 4 TEMP. SETPOINT 6 7 1 BYPASS / FAN 24V ~ 22 24V 0 23 LON 1 24 LON 2 25 COMMON CO2 OUT 24 VAC LED IN Excel 12 24V ~ 1 24V 0 2 LON 1 3 LON 2 4 C7110D Fig. Connection to LonWorks (fixed terminals) Depending upon the chosen network configuration, one or two terminations (see section "LONWORKS Termination" on page 7) may be required. LonWorks Communications The Excel 12 is equipped with a free-topology transceiver (FTT10A) for communicating on LONWORKS® networks. The LONWORKS network is insensitive to polarity, eliminating the possibility of installation errors due to miswiring. Different network configurations (daisy-chain, loop, and star configurations, or any combination thereof) are possible (see also Excel 50/500 LONWORKS Mechanisms Interface Description, EN0B-0270GE51). All Excel 12 controllers feature a LONWORKS service LED and service button (see section "Troubleshooting" on page 6). General Information Inputs/Outputs Use a min. length of all input/output cables is 1300 ft (400 m). Two wires with a total thickness of 14 AWG can be twisted together and connected using a wire nut (include a pigtail with this wire group and attach the pigtail to the individual terminal block). Wire to the terminal blocks as follows: Wiring the Inputs/Outputs 5 EN1B-0201GE51 R0110F EXCEL 12 MODULES 1. Insert it at the required terminal location, and tighten the screw to complete the termination. [. . . ] First power-up with a new PROM on a Neuron 3150 Chip-based custom node. First power-up with a new PROM on a Neuron 3150 Chip-based custom node. First power-up with a new PROM on a Neuron 3150 Chip-based custom node. Node is configured and running normally. 6b 6c 6d 7 8 9 LED remains OFF after a short ON duration. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL EXCEL 12




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL EXCEL 12 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.