User manual HONEYWELL EW773 DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL EW773. We hope that this HONEYWELL EW773 user guide will be useful to you.


HONEYWELL EW773 DATASHEET: Download the complete user guide (481 Ko)

Manual abstract: user guide HONEYWELL EW773DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] IP 54 O: : 15 DN : 16 PN : 773 0 Typ 30000 77 0 t 50 r: P nso 80°C T. se 0. . . . . 1 . 177K O: : 3. . . . l cla ss: 2 ron a a Envi chanic ical cl Me trolog Me 7 0 TB017 M 0 -MI004r-P 6 102 . Features · MID approval · First approval in Europe for ultrasonic heat meter with dynamic range of qi/qp m³/h 1:250 in class 2 (qp 1. 5 / 2. 5 / 6. 0m³/h) · Complete dynamic range 1:1, 500 · 12 years battery lifetime · Meters up to qp 6 with patented free-beam principle and robust swirl-free flow around reflector made of stainless steel Design Hydronic meters of the EW773 Series consist of: · Electronic energy integrator with cable connection to the ultrasonic volume measuring component, supply and return temperature probe · Ultrasonic volume measuring component with external threads according to ISO228 (DN15. . . DN25) or flanges (DN25. . . DN80) · Meters qp10 and larger with direct beam principle · Standard housing dimensions · Can be used for heating (EW7730), cooling or both (EW7731) · Available in nominal sizes from qp 0. 6 up to 40m³/h · Measuring accuracy meets the requirements of EN1434 class 2 and 3 · No calming leg required on inlet or outlet for sizes up to qp 0. 6m³/h · Power save mode · Remote reading via M-Bus, RF, RS232 or optical interface · Optional plug and play modules · Individual tariff functions · History memory for 24 months · Extensive diagnostic displays · Windows based HYDRO-SET parametrization software for optimum adaptation to the user's specific needs Materials · Housing of electronic energy integrator made of black and transparent plastic · Housing of ultrasonic volume measuring component made of brass Honeywell Subject to change EN0H-2600GE25 R0809 EW773 SERIES ULTRASONIC HYDRONIC METERS Specifications Medium Medium temperature Ambient temperature Operating pressure kvs (cv)-values Ambient class Protection class Type Measuring process Display Units Total values Values displayed Temperature sensors Sensor current Measuring cycle Max. temperature difference Starting temperature difference Absolute temperature measuring range Operating voltage Water, quality to VDI2035 see table below 0. . . 55°C (32. . . 131°F) Threaded versions: PN16 Flanged versions: PN25 see table below EN1434 class C / A IP54 / IP64 (EW7731 volume measuring component only) Static heat meter to EN1434 Ultrasonic volume measurement LCD, 7-digit MWh ­ kWh ­ GJ ­ Gcal ­ MBtu 9 999 999 ­ 999 999. 9 ­ 99 999. 99 ­ 9 999. 999 Power ­ Energy ­ Flow rate ­ Temperature Pt500 with 2-wire leads Pt500 peak < 2; rms < 0. 012mA Battery supply: 16s Mains unit supply: 1s 177K 3K 0. 25K -9. 9. . . 189. 9°C (14. 2. . . 373. 8°F) qp0. 6. . . 6: 3. 0V lithium battery qp10. . . 40: 3. 6V lithium battery qp Medium temperature Flow rates Maximum (qs) Nominal (qp) Minimum (qi) Starting kvs (cv)-value p at qp NOTE: m3/h m3/h l/h l/h m3/h mbar 0. 6 1. 0 1. 5 2. 5 3. 5 6. 0 10 15 25 40 EW7730: 20. . . 130°C (68. . . 266°F) EW7731: 5. . . 130°C (41. . . 266°F) EW7730: 20. . . 150°C (68. . . 302°F) EW7731: 5. . . 150°C (41. . . 302°F) 1. 2 0. 6 6 1 2. 06 (2. 41) 85 2 1 10 2. 5 5. 27 (6. 17) 36 3 1. 5 6 2. 5 5. 48 (6. 41) 75 5 2. 5 10 4 7. 91 (9. 25) 100 7 3. 5 35 7 16. 7 (19. 5) 44 12 6 24 7 16. 8 (19. 7) 128 20 10 401/100 15 32. 5 (38. 0) 95 30 15 150 30 61. 2 (71. 6) 60 50 25 250 50 94. 5 (111) 70 80 40 400 80 127 (149) 100 Medium temperature may be limited by installation position, see chapter 'Installation' on page 6. 1 when mounted in horizontal position 2 Honeywell Subject to change EN0H-2600GE25 R0809 EW773 SERIES ULTRASONIC HYDRONIC METERS Function Integrator The integrator contains all the necessary circuits for recording flow rate and temperature and for calculating, logging and displaying the data. The integrator housing can be mounted directly onto the volume measuring component or to the wall. [. . . ] The pulse value and the unit is configurable for energy, water, gas or electrical metering by the HYDRO-SET software. Pulse Output The meter provides levels for two optional external pulse outputs, which can be freely programmed using the HYDROSET software. Possible pulse output values · Energy (standard setting) · Volume (standard setting) · Tariff energy 1 · Tariff energy 2 · Tariff condition 1, limit switch · Tariff condition 2, limit switch Honeywell Subject to change 3 Monthly Memory The EW773 Series has a history memory of 24 months. The following values are stored in the EEPROM on the programmed date 1. . . 31 of the actual month: · Date / Time · Volume · Energy · Error day counter · Maximum monthly flow rate · Maximum monthly power · Date of maximum monthly flow rate · Date of maximum monthly power · Tariff energy 1 · Tariff energy 2 · Tariff definition 1 · Tariff definition 2 · Impulse counter 1 · Impulse counter 2 EN0H-2600GE25 R0809 EW773 SERIES ULTRASONIC HYDRONIC METERS Log Memory The log memory is used to store consumption values. The storage frequency can be selected from various storage intervals (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30, 60 minutes or the default setting of 24 hours, see Table 1). The data saved in the log memory can be used for the following analyses: · Reading the meter on a certain day · Example: if the day for reasing is 01. 10 (1 October), the meter reading is displayed for the period from 01. 10 of the previous year to 30. 09 of the current year. · Comparison of the last consumption period with the preceding period Table 1. Extract of possible log memory settings Storage interval Number of data records 5 minutes Error status, overload 440 15 minutes time temperature, 440 overload time flow rate, 440 1 hour forward temperature, 24 hours 440 return temperature, date and time, energy, tariff energy 1, tariff energy 2, tariff definition 1, tariff definition 2, volume, error day counter Values Recording period 36. 6 hours 110 hours 18. 3 days 440 days Tariff Function The integrator offers two optional tariff memories for monitoring plant load states for limit tariffs. Extensive tariff conditions make it possible to adapte the meter individually to the required customer-specific applications. The following limit types are possible (this example applies to the display with 3 decimal places): Table 2. 25 500 l/h LIMIT resolution 1 °C 1 °C 1 kW 100 l/h P Q Display Control The readings are displayed on the meter by a 7-digit LCD with units and symbols Loop Structure The EW773 Series display has six loops. Some display windows consist of two (to maximum seven) displays that are shown alternately at 4-second intervals. NOTE: For quick visual guidance, the loops in the display are numbered from 1 to 6. Maximum Values The integrator creates max. values for power and flow rate based on consumption time, which are stored in the EEPROM. Default setting is 60 minutes. The main loop with the current data, e. g. Loop overview EN0H-2600GE25 R0809 4 Honeywell Subject to change EW773 SERIES ULTRASONIC HYDRONIC METERS Table 3. Display Contents Loop , , 1" Sequence 1. 1 1. 2 1. 3 Main loop 1. 4 1. 5 1. 6 1. 7 1. 8[OFF] 1. 9 1. 10 1. 11[OFF] 1. 12[OFF] 1. 13[OFF] 1. 14[OFF] Window 1 Accumulated energy Volume Flow rate Power Forward temperature Difference temperature Operating hours Monthly peak power Error code Display test Tariff energy 1 Tariff energy 2 `In 1' `In 2' Window 2 Window 3 Return temperatur Date Pulse input counter 1 Pulse input counter 2 Window 2 Accounting date 1 energy Accounting date 1 previous year energy Accounting date 1 in the future Accounting date 2 energy Accounting date 2 previous year energy Accounting date 2 in the future Window 2 Secundary address Primary address Date max. power Window 3 [OFF] Window 4 Accounting date 1 volume , Accd 1' Accounting date 1 , Accd 1' previous year volume Loop , , 2" Sequence Window 1 2. 1 Accounting date 1 2. 2 Accounting date 1 previous year Accoun2. 3 , Accd 1' ting date loop 2. 4 Accounting date 2 2. 5 Accounting date 2 previous year 2. 6 , Accd 2' Window 1 Current date , SEC_Adr' , Pri_Adr' , Pt 100 r' or , Pt 500 r' Monthly peak flow rate Monthly peak power Integration interval (maximum value) Number of error day's , Out1' , Out2' Accounting date 2 volume , Accd 2' Accounting date 2 , Accd 2' previous year volume Loop , , 3" Sequence 3. 1 3. 2 3. 3 Info loop 3. 4 3. 5 3. 6 3. 7 3. 8 3. 9 3. 10 Window 3 Pulse value and unit pulse output 1 Pulse value and unit pulse output 2 Window 2 Pulse input counter 1 Pulse input counter 2 , In1' , In2' , In1' , In2' , In1' , In2' , In1' , In2' Window 3 Pulse value 1 Pulse value 2 Acc. A short press of the button (< 3 seconds) switches to the next display within a loop and a long press (> 3 seconds) switches to the next display loop. The "Energy" window (sequence 1. 1) in the main loop is the basic display. [. . . ] Dimensions Nominal size DN size Body length Overall length with fittings Height of pipe axis to top of electronics Height of pipe axis to bottom of valve housing Body thread Fitting thread (accessory) Flange diameter Flange dimension Bolt circle diameter Weight NOTE: L [mm] L1 [mm] H [mm] h [mm] qp [m3/h] 0. 6/1. 0/1. 5 15 110 190 78 14. 5 2. 5 20 130 230 80 18 25 260 380 84. 5 23 84. 5 3. 5 25 260 25 260 380 84. 5 23 84. 5 90 91 91 91 6. 0 32 260 10 40 300 15 50 270 25 65 300 40 80 300 G [inch] R [inch] D [mm] F [mm] d [mm] [kg] G3/4B R1/2 G1B R3/4 G1 1/4B Flanged G1 1/4B Flanged Flanged Flanged Flanged Flanged R1 114 100 85 R1 139 125 100 1. 5 4. 8 148 138 110 7. 0 163 147 125 8. 5 184 170 145 10. 8 198 188 160 12. 6 0. 76 0. 85 1. 5 3. 5 Threaded tailpieces are not supplied with the heat meter Honeywell Subject to change 7 EN0H-2600GE25 R0809 EW773 SERIES ULTRASONIC HYDRONIC METERS Ordering Information Table 5. Order Specification Overview Size qp 0. 6m3/h 1. 0m3/h 1. 5m3/h 2. 5m3/h 3. 5m3/h 3. 5m3/h 6. 0m3/h 6. 0m3/h 10m3/h 15m3/h 25m3/h 40m3/h 0. 6m3/h 1. 0m3/h 1. 5m3/h 2. 5m3/h 3. 5m3/h 3. 5m3/h 6. 0m3/h 6. 0m3/h 10m3/h 15m3/h 25m3/h 40m3/h 0. 6m3/h 1. 0m3/h 1. 5m3/h 2. 5m3/h 3. 5m3/h 3. 5m3/h 6. 0m3/h 6. 0m3/h 10m3/h 15m3/h 25m3/h 40m3/h DN size DN15 DN15 DN15 DN20 DN20 DN25 DN20 DN32 DN40 DN50 DN65 DN80 DN15 DN15 DN15 DN20 DN20 DN25 DN20 DN32 DN40 DN50 DN65 DN80 DN15 DN15 DN15 DN20 DN20 DN25 DN20 DN32 DN40 DN50 DN65 DN80 Length 110mm 110mm 110mm 130mm 260mm 260mm 260mm 260mm 300mm 270mm 300mm 300mm 110mm 110mm 110mm 130mm 260mm 260mm 260mm 260mm 300mm 270mm 300mm 300mm 110mm 110mm 110mm 130mm 260mm 260mm 260mm 260mm 300mm 270mm 300mm 300mm Connection G3/4B G3/4B G3/4B G1B G1 1/4B Flanges PN25 G1 1/4B Flanges PN25 Flanges PN25 Flanges PN25 Flanges PN25 Flanges PN25 G3/4B G3/4B G3/4B G1B G1 1/4B Flanges PN25 G1 1/4B Flanges PN25 Flanges PN25 Flanges PN25 Flanges PN25 Flanges PN25 G3/4B G3/4B G3/4B G1B G1 1/4B Flanges PN25 G1 1/4B Flanges PN25 Flanges PN25 Flanges PN25 Flanges PN25 Flanges PN25 Interface None None None None None None None None None None None None M-Bus M-Bus M-Bus M-Bus M-Bus M-Bus M-Bus M-Bus M-Bus M-Bus M-Bus M-Bus M-Bus+2 pulse inputs M-Bus+2 pulse inputs M-Bus+2 pulse inputs M-Bus+2 pulse inputs M-Bus+2 pulse inputs M-Bus+2 pulse inputs M-Bus+2 pulse inputs M-Bus+2 pulse inputs M-Bus+2 pulse inputs M-Bus+2 pulse inputs M-Bus+2 pulse inputs M-Bus+2 pulse inputs OS-No. EW7731 EW7730A0100 EW7730A0600 EW7730A1200 EW7730A2000 EW7730A2800 EW7730A3000 EW7730A3600 EW7730A4000 EW7730A4800 EW7730A5200 EW7730A6000 EW7730A7000 EW7730M0100 EW7730M0600 EW7730M1200 EW7730M2000 EW7730M2800 EW7730M3000 EW7730M3600 EW7730M4000 EW7730M4800 EW7730M5200 EW7730M6000 EW7730M7000 EW7730K0100 EW7730K0600 EW7730K1200 EW7730K2000 EW7730K2800 EW7730K3000 EW7730K3600 EW7730K4000 EW7730K4800 EW7730K5200 EW7730K6000 EW7730K7000 EW7731A0100 EW7731A0600 EW7731A1200 EW7731A2000 EW7731A2800 EW7731A3000 EW7731A3600 EW7731A4000 EW7731A4800 EW7731A5200 EW7731A6000 EW7731A7000 EW7731M0100 EW7731M0600 EW7731M1200 EW7731M2000 EW7731M2800 EW7731M3000 EW7731M3600 EW7731M4000 EW7731M4800 EW7731M5200 EW7731M6000 EW7731M7000 EW7731K0100 EW7731K0600 EW7731K1200 EW7731K2000 EW7731K2800 EW7731K3000 EW7731K3600 EW7731K4000 EW7731K4800 EW7731K5200 EW7731K6000 EW7731K7000 Scope of Delivery · EW773 Series heat meter with supply and return temperature sensor · 2 sealings · Fitting for installation of supply temperature sensor · Wall mounting plate · Operating and setup instructions EN0H-2600GE25 R0809 8 Honeywell Subject to change EW773 SERIES ULTRASONIC HYDRONIC METERS Accessories Union nut, sealing and externally threaded red bronze tailpiece for external threads DN 15 VA7401A015 DN 20 VA7401A020 DN 25 VA7401A025 Sanpress red bronze compression-fitting with sealing DN15, for 15 mm pipe-Ø VA7404A015 DN15, for 18 mm pipe-Ø VA7404A018 DN20, for 22 mm pipe-Ø VA7404A020 DN25, for 28 mm pipe-Ø VA7404A025 Union nut, sealing and internally threades red bronze tailpiece DN 15 VA7405A015 DN 18 VA7405A018 DN 20 VA7405A020 DN 25 VA7405A025 Ballvalve with connection for supply temperature probe G1/2" internal thread EWA087HY004 G3/4" internal thread EWA087HY005 G1" internal thread EWA087HY006 Tailpiece for connection of supply temperature sensor R1/2 external thread, EWA087HY003 M10x1 sensor thread G1/4" external thread, EWA354830 M10x1 sensor thread Brass immersion pockets (for use with MID meters) 35mm EWA3002684 52mm EWA3002685 85mm EWA3004406 120mm EWA3004407 Modules M-Bus communication module (for upgrade of EW773xA types) Pulse output module (2 outputs) Pulse input module (2 inputs) RF communication module Combined pulse in- and output module RS232 interface module with cable EWA54200001 EWA54200002 EWA54200003 EWA54200017 EWA54200026 EWA54200030 Ballvalve with two side connections G1/4" internal thread and one blind stop G1/2" internal threads VB550SY2015 G3/4" internal threads VB550SY2020 G1" internal threads VB550SY2025 G1 1/4" internal threads VB550SY2032 G1 1/2" internal threads VB550SY2040 NOTE: Only available in packing units of 6 pcs or 8 pcs (3/4") For connection of supply temperature sensor adapter EWA354830 is required Measuring Accuracy Fig. Measuring accuracy to EN1434 Class 2 Honeywell Subject to change 9 EN0H-2600GE25 R0809 EW773 SERIES ULTRASONIC HYDRONIC METERS Flow Diagram 0, 6 1. 0 1. 5 2. 5 3. 5 6. 0 10 15 25 40 400000 50 Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL EW773




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL EW773 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.