User manual HONEYWELL DT92

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL DT92. We hope that this HONEYWELL DT92 user guide will be useful to you.


HONEYWELL DT92 : Download the complete user guide (1677 Ko)

Manual abstract: user guide HONEYWELL DT92

Detailed instructions for use are in the User's Guide.

[. . . ] WIRELESS DIGITAL ROOM THERMOSTAT PRODUCT SPECIFICATION SHEET The new DT92 family of wireless digital room thermostats is a range of market leading products designed to provide comfort with economy in modern heating systems. Comprising a battery-powered room thermostat and a mains switching relay box, DT92 features robust 2-way RF communications between the units. The RF link between both units is already set (prebound) at the factory, so the product is ready for immediate installation. Energy efficiency is addressed by state-of-the-art TPI control performance and an ECO button energy saving feature. [. . . ] If products from individual system packs are separated, or mixed with other pre-configured system packs during installation, or a faulty unit is being replaced, the desired units must be specially configured to allow them to communicate with each other. Bind room thermostat to relay box Reset Stored Data in Relay Box Press and hold the push button for 15s to reset the stored data in the BDR91 relay box. The red LED will give a brief flash every second to verify reset has happened. Put Relay Box into Binding Mode Press and hold the push button for 5s to put the BDR91 relay box into binding mode. The red LED will flash 0. 5 seconds on, 0. 5 seconds off to verify it is now in binding mode. The BDR91 relay box will remain in binding mode for 3 minutes, before generating an error message if no valid binding instruction has been received. It must be put back into binding mode if further attempts to bind are required. 10 DT92 WIRELESS DIGITAL ROOM THERMOSTAT Reset Stored Data in Room Thermostat Follow the sequence of steps below to reset the stored binding data in the room thermostat. Put Room Thermostat into Binding Mode Bind Room Thermostat to Relay Box With both units in binding mode, pressing the off/standby button on the room thermostat will bind them together. To verify it is now bound, the red light on the relay box will immediately stop flashing. After about 5 seconds, the room thermostat will come out of binding mode and go back to off mode. 11 DT92 WIRELESS DIGITAL ROOM THERMOSTAT SYSTEM OPERATION RF Signal Propagation As the DT92 room thermostat and relay box communicate using RF technology, special care must be taken during installation. The location of the RF components as well as the building structure may influence performance of the RF system. DT92 uses 2-way RF technology, and this allows the signal strength to be measured and communicated, to ensure correct placement of the room thermostat in a high signal strength area. See RF Communication Test and Signal Strength Test sections for a description of these features. Within a typical residential building the two products should communicate reliably within a 30m range. It is important to take into consideration that walls and ceilings will reduce the RF signal. The strength of the RF signal reaching the Relay Box depends on the number of walls and ceilings separating it from the room thermostat, as well as the building construction the diagram below illustrates an example of typical signal strength reduction. Walls and ceilings reinforced with steel or plasterboard walls lined with metal foil reduce the RF signal significantly more. Automatic Operation The display on the DT92 room thermostat will indicate (by means of the flame symbol) the actual status of the relay in the BDR91 relay box. The green LED on the BDR91 relay box will illuminate when the relay is on, and will go off when the relay is switched off. 12 DT92 WIRELESS DIGITAL ROOM THERMOSTAT Temporary Manual Override Pressing the button on the BDR91 will temporarily override the current relay operation. The green LED will indicate the relay position. Loss of RF Communications If RF communications is lost, for whatever reason, the BDR91 relay box will operate in failsafe mode (as set in the Installer Mode) and the red LED will illuminate. The DT92 room thermostat will flash the RF symbol until communications are restored. PRODUCT DIMENSIONS 90 27 90 30. 5 92 13 DT92 WIRELESS DIGITAL ROOM THERMOSTAT INSTALLER MODE ­ APPLICATIONS SETTINGS The DT92 has a special Installer Mode where some features can be adjusted to suit the application and the needs or lifestyle of the user. Parameter Minimum ON/OFF time Description and typical use DT92 is able to set a minimum limit for the on and off times of the controlled device or appliance, to prevent damage or excessive wear. This minimum time can be set to 1, 2, 3, 4, or 5 minutes, and is particularly important for heating applications with oil boilers, or air conditioning applications with compressors. Within the control proportional band, the output will be cycled several times per hour, to give precise temperature control. This can be set to 3, 6, 9, or 12 cycles, depending on the application. The proportional band is the temperature band, adjacent to the set temperature point, within which the thermostat will cycle the controlled output (to control the boiler, for example). [. . . ] Now press and hold both and temperature adjustment buttons for 3 seconds, until the display shows the word "Inst". The parameter code is shown on the display separated by a colon from the parameter value. Parameter Value To select and change a parameter: d. Press the off/standby button to select the parameter value, ready to change f. When the correct value is flashing, confirm the selection by pressing the off/standby button again, returning to the parameter menu. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL DT92




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL DT92 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.