User manual HONEYWELL DPTM50-5000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL DPTM50-5000. We hope that this HONEYWELL DPTM50-5000 user guide will be useful to you.


HONEYWELL DPTM50-5000 : Download the complete user guide (969 Ko)

You may also download the following manuals related to this product:

   HONEYWELL DPTM50-5000 (970 ko)

Manual abstract: user guide HONEYWELL DPTM50-5000

Detailed instructions for use are in the User's Guide.

[. . . ] 3-WIRE DIFFERENTIAL PRESSURE TRANSMITTERS WITH CURRENT AND VOLTAGE OUTPUT SPECIFICATION DATA & MOUNTING INSTRUCTIONS DPTM50-5000 FEATURES · · · · · · · · · Monitoring gaseous, non-aggressive media Piezo-resistive pressure transducer Up to 40 kPa (60 kPa) overload capacity Rugged design; protection class IP54 Easy installation and wiring connection Measurement range adjustable by jumper Response time adjustable by jumper Output signal adjustable by jumper Re-zeroing possible by pushbutton NOTE: These sensors are not suitable for use in installations under periodic inspection by the U. S. [. . . ] The pressure to be measured is applied to and thus deflects a thin membrane made of monosilicon. The membrane's semiconductor resistors (arranged to simultaneously compensate for the temperature response) detect this deflection and generate an electrical output signal. The output signal is converted into the 0. . . 10 V or 4. . . 20 mA analog signal which changes (within the specified error limits) in proportion to the applied pressure. This can be changed (except for +/- models) to pressure range 2 by removing the corresponding jumper (see Fig. This can be changed to 100 ms by removing the corresponding jumper (see Fig. NOTE: The devices are factory pre-set to an output signal of 0. . . 10 V. This can be changed to 0. . . 20 mA by removing the corresponding jumper (see Fig. Mounting WIRING PRESSURE RANGE jumper inserted = pressure range 1 jumper removed = pressure range 2 RESPONSE TIME jumper inserted = 1 sec jumper removed = 100 msec ACCESSORIES DPSK: Included in delivery. [. . . ] Box 1254 71099 Schönaich Germany phone: (49) 7031-637-02 fax: (49) 7031-637-850 http://www. honeywell. de/fema Subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL DPTM50-5000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL DPTM50-5000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.