User manual HONEYWELL CT8775C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL CT8775C. We hope that this HONEYWELL CT8775C user guide will be useful to you.


HONEYWELL CT8775C : Download the complete user guide (432 Ko)

You may also download the following manuals related to this product:

   HONEYWELL CT8775C (483 ko)

Manual abstract: user guide HONEYWELL CT8775C

Detailed instructions for use are in the User's Guide.

[. . . ] THE DIGITAL ROUNDTM NON-PROGRAMMABLE THERMOSTATS OWNER'S GUIDE CT8775A, C CT8775A Heat Only Thermostat (20 to 30 Vac) and CT8775C Heating-Cooling Thermostat (20 to 30 Vac) Para obtener un documento con las instrucciones en español, por favor visite nuestro sitio de web a: www. honeywell. com/yourhome. Pour obtenir des notices techniques en français, veuillez consulter notre site web www. honeywell. com/yourhome. Contents Step 1. Prepare for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remove Old Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Attach the decorator cover plate (if used) and wallplate to the wall with two 1-in. screws. 69-1676 6 Mount Decorator Cover Plate (Required) and Wallplate onto Electrical Box Pull the wires through the wiring hole on the decorator cover plate. Place the decorator cover plate against the electrical box so that the UP indicator in the middle of the decorator cover plate is pointing up. Line up the screw slots on the decorator cover plate with the electrical box screw holes, and attach the decorator cover plate to the electrical box with two 1/2 in. Turn the wallplate until the wiring holes are aligned and the two screw holes on the left and right side of the wallplate line up with the screw holes on the decorator cover plate. Attach the wallplate to the decorator cover plate with the two 3/8 in. screws. ELECTRICAL BOX DECORATOR COVER PLATE 1/2 INCH SCREW (2) WALL PLATE 3/8 INCH SCREW (2) A 1 1 IF ELECTRICAL BOX IS HORIZONTAL, MOUNT DECORATOR COVER PLATE IN POSITION SHOWN, BUT FASTEN WITH SCREWS THROUGH "A". M19494 WIRING HOLES Fig. Mount decorator cover plate (required) and wallplate onto electrical box (heating-cooling wallplate shown). 7 69-1676 STEP 7. WIRE WALLPLATE TERMINALS IMPORTANT All wiring must comply with local codes and ordinances. If unsure about household wiring procedures, call your local heating/air conditioning contractor. Refer to the labels you placed on the wires when you removed the old thermostat (see illustration). Match the letter of your old thermostat wire with the corresponding terminal letter on your new thermostat. IMPORTANT Remove the factory-installed jumper connecting terminals R and Rc on the CT8775C Thermostat if wires will be connected to both of these terminals. Wraparound and straight connections are both acceptable, (see illustration). NOTE: The CT8775A, C Thermostats will provide optimal temperature control if DIP switches 1 and 2 are set according to your particular heating system. Fig. Heating System Steam, Gravity Gas or Oil Warm Air (factory setting) Electric Warm Air In Floor Radiant Heat NOTE: Cycles Per Hour DIP Switch 1 DIP Switch 2 1 6 9 On Off Off On On On Off Off High Efficiency Warm Air (90%+ efficiency), Hot Water, Heat Pump 3 Check with manufacturer for recommended cycle rate. The cooling cycle rate does not require adjustment and therefore cannot be changed. Fahrenheit/Celsius Indication Use DIP switch 3 to set the desired temperature indication. Fahrenheit/Celsius Display Fahrenheit (factory setting) Celsius DIP Switch 3 Off On STEP 9. MOUNT THE THERMOSTAT ENGAGE TABS AT BOTTOM OF THERMOSTAT AND WALL PLATE. PRESS UPPER EDGE OF CASE TO LATCH M19498 11 69-1676 STEP 10. SET THE SYSTEM AND FAN SWITCHES (CT8775C ONLY) System Switch (see Fig. Use for improved air circulation. (CT8775C ONLY) SELECTS COOL/OFF/HEAT (CT8775C ONLY) SELECTS ON/AUTO ROOM SET SHOWS THAT THE CURRENT ROOM TEMPERATURE IS DISPLAYED DISPLAYS ROOM OR SET TEMPERATURE SHOWS THAT THE CURRENT TEMPERATURE SETTING IS DISPLAYED DISPLAYS AND ADJUSTS TEMPERATURE SETTING/ TURNS BACKLIGHT ON M19512 Fig. OPERATING THE THERMOSTAT NOTE: Batteries are not required because the temperature setting is held permanently in memory. Backlit Display The backlight can be turned on by turning the dial, or pushing the backlight button (see Fig. [. . . ] For additional information, go to www. honeywell. com/yourhome or call Honeywell Customer Care, toll free, at 1-800-468-1502. Before calling, please have the following information available: · Thermostat model number. · Type of heating/cooling system (example: Gas, oil, or electric; warm air, hot water, heat pump, steam or gravity). 15 69-1676 Wiring Diagrams O 2 R W R Rc B G Y W 1 HEATING RELAY OR VALVE COIL 1 HEATING RELAY OR VALVE COIL FAN RELAY 1 POWER SUPPLY. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL CT8775C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL CT8775C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.