User manual HONEYWELL CT3611

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL CT3611. We hope that this HONEYWELL CT3611 user guide will be useful to you.


HONEYWELL CT3611 : Download the complete user guide (970 Ko)

You may also download the following manuals related to this product:

   HONEYWELL CT3611 (1104 ko)
   HONEYWELL CT3611 (269 ko)

Manual abstract: user guide HONEYWELL CT3611

Detailed instructions for use are in the User's Guide.

[. . . ] PROGRAMMABLE THERMOSTAT OWNER'S GUIDE Seven Day Programmable Heat Pump Low Voltage (20 to 30 Vac) Thermostat and Wallplate Model CT3611 Para pedir estas instrucciones en español, llame al 1-800-468-1502. Pour obtenir ce ode demploi en français, composer le 1-800-468-1502. Honeywell CT3611 Table of Contents Step 1. Prepare for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remove Old Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] --The program period when you want the house at a comfortable temperature for activities before bedtime. Return (This is a higher temperature during the heating season and a lower temperature during the cooling season). --The program period you can set for an energy-saving temperature while you are sleeping. (This is a lower Sleep temperature during the heating season and a higher temperature during the cooling season). 69-1081--3 12 Table 2 can be helpful when planning your schedule of time and temperature settings. Period Wake Default Setting Time (6:00AM) Heata (70°F/21°C) Coolb (78°F/25. 5°C) Leave Time (8:00AM) Heata (62°F/16. 5°C) Coolb (85°F/29. 5°C) Return Time (6:00PM) Heata (70°F/21°C) Coolb (78°F/25. 5°C) Sleep Time (10:00PM) Heata (62°F/16. 5°C) Coolb (82°F/28°C) a Your b Monday (Mon) Tuesday (Tue) Wednesday Thursday (Wed) (Thu) Friday (Fri) Saturday (Sat) Sunday (Sun) heating setpoints cannot be higher than 90°F (32°C) or lower than 40°F (4. 5°C). Your cooling setpoints cannot be higher than 99°F (35°C) or lower than 45°F (7°C). Program the First Day Start by programming the wake time and temperature for one day. q q q Press and release Press Day Wake . until the desired day displays. (Mon, Tue, Wed, Thu, Fri, Sat, Sun) or until the desired time shows in the display. 13 69-1081--3 Press time NOTE: q Press Program times are in 15 minute intervals. or until the desired wake temperature displays. The setpoint temperature range is 40°F to 90°F (7°C to 31°C) for heating and 45°F to 99°F (9°C to 37°C) for cooling. q Press Heat/Cool Settings to switch between setpoints. NOTE: q q q Press Press Program times are the same for heating and cooling. or Leave until the display shows the desired temperature setpoint. , Return or Sleep and repeat these steps for each program period. The first day is now programmed. Repeat each step in Program the First Day for the rest of the week. After the first day is programmed, you can copy that day to any other day using procedure in Copy a Day. Run Program NOTE: q Press when the entire week is programmed. Copy a Day Your thermostat can copy program settings from one day to another. q q q Press Press Press Wake , Leave , Return or Sleep to enter programming mode. Day until the display shows the day you want to copy. The display shows. Mon Copy M13327 q Press Day until the display shows the day you want to copy to. Mon Wed M13328 69-1081--3 14 q q Press Copy to accept the change. Repeat these steps for each day you want to copy. donE appears for two seconds and then the normal program display appears. M13329 NOTE: Clear a Program Period NOTE: q q q q q Press Press Wake cannot be cleared. Leave , Return , or Sleep for the program period you want to clear. Day until the desired day displays. Leave Press and hold the , Return , or Sleep for approximately 3 seconds until the time and temperature clear. Repeat the above steps for each period to be cleared. OPERATING YOUR THERMOSTAT Change Temperature Setting Until the Next Program Period (Temporary Change) q Press or until the screen shows the desired temperature setting. NOTE: The temporary temperature setting is displayed for about 3 seconds and then the room temperature is displayed. The setting cancels when the next program period starts or when you press Run Program . 15 69-1081--3 Change Temperature Setting Indefinitely (Hold) q q q Move the System switch to the desired position (Heat or Cool). (The display changes from showing the setpoint temperature to room temperature after approximately three seconds). [. . . ] 66°F · Your CT3611 thermostat learns from Recovery experience. Each day it checks how Begins 1 closely it hit the recovery target and then 64°F adjusts the next day's recovery start System Operating in Energy Savings Mode time accordingly. 62°F · It takes a few days after installation for the thermostat to adjust to the local 5:00 5:30 6:00 6:30 weather, your lifestyle, the construction ENERGY COMFORT RECOVERY FROM ENERGY SAVINGS SAVINGS PERIOD of your home, and your heating/cooling PERIOD TIME system. THERMOSTAT USES THE SAME SCHEME TO RETURN TO LOWER COMFORT TEMPERATURE DURING THE COOLING SEASON. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL CT3611




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL CT3611 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.