User manual HONEYWELL CT3595

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL CT3595. We hope that this HONEYWELL CT3595 user guide will be useful to you.


HONEYWELL CT3595 : Download the complete user guide (476 Ko)

You may also download the following manuals related to this product:

   HONEYWELL CT3595 (922 ko)

Manual abstract: user guide HONEYWELL CT3595

Detailed instructions for use are in the User's Guide.

[. . . ] Honeywell CT3500/CT3595 OWNER'S GUIDE Weekday, Saturday and Sunday Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Wallplate Model CT3500/CT3595 Para pedir estas instrucciones en español, llame al 1-800-468-1502. Pour obtenir ce ode demploi en français, composer le 1-800-468-1502. PROGRAMMABLE THERMOSTAT Table of Contents Step 1. Prepare for Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remove Old Thermostat. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] -- 1 = Smart Response technology off. M13343 To turn Smart Response technology on or off: !Press Time NOTE: to return to main display. See Smart Response technology (page 21) for information about this feature. Temperature Format (Feature Number 14) Temperature format options are: -- 0 = °F (preset). Press Time to return to main display. 69-1199--4 12 Time Format (Feature Number 16) Time format options are: -- 0 = 12-hour clock (preset). Press once. Run Program to return to main display. Factory Set Function (Feature Number 37) Do not change this setting. STEP 9. SET THE CLOCK Set Current Day and Time NOTE: On initial power-up, the screen flashes 1:00 pm until you press a key. Set Curent Day/Time Day M13346 !The thermostat displays day, time, program period, temperature and system settings. There is an individual key for each of the four program periods: --The program period when you want the house at a comfortable temperature when you get up and while you Wake get ready for work or school. (This is a higher temperature during the heating season and a lower temperature during the cooling season). --The program period you can set for an energy-saving temperature while you are away at work or school. Leave (This is a lower temperature during the heating season and a higher temperature during the cooling season). --The program period when you want the house at a comfortable temperature for activities before bedtime. Return (This is a higher temperature during the heating season and a lower temperature during the cooling season). Sleep --The program period you can set for an energy-saving temperature while you are sleeping. (This is a lower temperature during the heating season and a higher temperature during the cooling season). Table 3 can be helpful when planning your schedule for time and temperature settings. The thermostat preprogrammed settings are shown in parentheses ( ). 69-1199--4 14 Table 3. Period Wake Default Setting Time (6:00AM) Heata (70°F/21°C) Coolb (78°F/25. 5°C) Leave Time (8:00AM) Heata (62°F/16. 5°C) Coolb (85°F/29. 5°C) Return Time (6:00PM) Heata (70°F/21°C) Coolb (78°F/25. 5°C) Sleep Time (10:00PM) Heata (62°F/16. 5°C) Coolb (82°F/28°C) a b Weekday (Mon-Fri) Saturday (Sat) Sunday (Sun) Your heating setpoints cannot be higher than 90°F (32°C) or lower than 40°F (4. 5°C). Your cooling setpoints cannot be higher than 99°F (35°C) or lower than 45°F (7°C). Program Weekdays Start by programming the wake time and temperature for weekdays. !key until the desired time shows in the display. until (Mon-Fri) displays. Press The setpoint temperature range is 40°F to 90°F (5°C to 2°C) for heating and 45°F to 99°F (7°C to 37°C) for cooling. !Press NOTE: Heat/Cool Settings to switch between heating and cooling setpoints. Program times are the same for heating and cooling. , Return or Sleep and repeat these steps for each time period. [. . . ] · You can turn off Smart Response technology by selecting Conventional Recovery. Customize Your Thermostat. System Operating in Comfort Mode 68 F Recovery Continues TEMPERATURE AM AM Mon Wake System Heat Room 66 F Recovery Begins 64 F System Operating in Energy Savings Mode 62 F Mon Sleep System Heat AM Room AM Mon Sleep System Heat Heat In Recovery Room Mon Sleep System Heat Heat In Recovery 1 Room 5:00 ENERGY SAVINGS PERIOD 5:30 6:00 6:30 COMFORT PERIOD RECOVERY FROM ENERGY SAVINGS TIME THERMOSTAT USES THE SAME SCHEME TO RETURN TO LOWER COMFORT TEMPERATURE DURING THE COOLING SEASON. 1 IF In Recovery IS DISPLAYED, PRESS TO SEE THE COMFORT SETPOINT. M18591 21 69-1199--4 WIRING DIAGRAMS 2-WIRE HEAT-ONLY (JUMPER INTACT) THERMOSTAT B RC O W Y R G R 4-WIRE HEAT/COOL (JUMPER INTACT) THERMOSTAT B RC O W Y G HEATING RELAY OR VALVE COIL 1 HEATING RELAY OR VALVE COIL COOLING CONTACTOR COIL FAN RELAY 1 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M10616 1 POWER SUPPLY. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL CT3595




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL CT3595 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.