User manual HONEYWELL CHRONOTHERM IV

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL CHRONOTHERM IV. We hope that this HONEYWELL CHRONOTHERM IV user guide will be useful to you.


HONEYWELL CHRONOTHERM IV : Download the complete user guide (597 Ko)

Manual abstract: user guide HONEYWELL CHRONOTHERM IV

Detailed instructions for use are in the User's Guide.

[. . . ] The fan setting feature is available on select thermostat models 3 69-1400—1 DELUXE PROGRAMMABLE THERMOSTAT Period Monday Wake Leave Return Sleep Tuesday Wake Leave Return Sleep Wake Leave Return Sleep Thursday Wake Leave Return Sleep Friday Wake Leave Return Sleep Saturday Wake Leave Return Sleep Sunday Wake Leave Return Sleep 69-1400—1 Start Time [6:00 AM] [8:00 AM] [6:00 PM] [10:00 PM] [6:00 AM] [8:00 AM] [6:00 PM] [10:00 PM] [6:00 AM] [8:00 AM] [6:00 PM] [10:00 PM] [6:00 AM] [8:00 AM] [6:00 PM] [10:00 PM] [6:00 AM] [8:00 AM] [6:00 PM] [10:00 PM] [6:00 AM] [8:00 AM] [6:00 PM] [10:00 PM] [6:00 AM] [8:00 AM] [6:00 PM] [10:00 PM] Heat Setpoint [70°F (21°C)] [62°F (16. 5°C)] [70°F (21°C)] [62°F (16. 5°C)] [70°F (21°C)] [62°F (16. 5°C)] [70°F (21°C)] [62°F (16. 5°C)] [70°F (21°C)] [62°F (16. 5°C)] [70°F (21°C)] [62°F (16. 5°C)] [70°F (21°C)] [62°F (16. 5°C)] [70°F (21°C)] [62°F (16. 5°C)] [70°F (21°C)] [62°F (16. 5°C)] [70°F (21°C)] [62°F (16. 5°C)] [70°F (21°C)] [62°F (16. 5°C)] [70°F (21°C)] [62°F (16. 5°C)] [70°F (21°C)] [62°F (16. 5°C)] [70°F (21°C)] [62°F (16. 5°C)] 4 Cool Setpoint [78°F (25. 5°C)] [85°F (29. 5°C)] [78°F (25. 5°C)] [82°F (28°C)] [78°F (25. 5°C)] [85°F (29. 5°C)] [78°F (25. 5°C)] [82°F (28°C)] [78°F (25. 5°C)] [85°F (29. 5°C)] [78°F (25. 5°C)] [82°F (28°C)] [78°F (25. 5°C)] [85°F (29. 5°C)] [78°F (25. 5°C)] [82°F (28°C)] [78°F (25. 5°C)] [85°F (29. 5°C)] [78°F (25. 5°C)] [82°F (28°C)] [78°F (25. 5°C)] [85°F (29. 5°C)] [78°F (25. 5°C)] [82°F (28°C)] [78°F (25. 5°C)] [85°F (29. 5°C)] [78°F (25. 5°C)] [82°F (28°C)] Fan Setting [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] Wednesday DELUXE PROGRAMMABLE THERMOSTAT Setting the Current Day and Time IMPORTANT Always press the keys with your fingertip or similar blunt tool. Sharp instruments like pens and pencil points can damage the keyboard. NOTE: On initial power up or after an extended power loss, 1:00 pm flashes on the display until a key is pressed. Set Day/Time PM Sleep Set Current Day/Time Time Run Program Set Current Day/Time Wake Set Program Leave Return Hold Temp Day Heat/Cool Settings System Fan Mon Daylight Time Copy M14619 2. Press Day until the current day is displayed. NOTE: Sun = Sunday, Mon = Monday, Tue = Tuesday, Wed = Wednesday, Thu = Thursday, Fri = Friday, Sat = Saturday. Set Day/Time PM Sleep Time Set Program Wake Leave Return Day Run Program Set Current Day/Time Hold Temp Day Heat/Cool Settings System Fan Tue Daylight Time Copy M14620 3. Press Time s or Time t until the current time is displayed. [. . . ] The setting is cancelled when the next period starts or when Run Program is pressed. Changing Temperature Setting Indefinitely 1. Press Hold Temp. Setting System Heat Time Set Program Wake Leave Return Sleep Hold Temp Run Program Set Current Day/Time Fan Hold Temp Day Heat/Cool Settings System Fan Heat Auto Daylight Time Copy M14651 2. Press increase s or decrease t key to change the setting, if desired. Setting System Heat Time Run Program Set Current Day/Time Wake Set Program Leave Return Sleep Fan Heat/Cool Settings System Fan Hold Temp Day Heat Daylight Time Copy Auto M14652 3. Press Heat/Cool Settings to change between heat and cool settings. Setting Heat/Cool Settings Time Run Program Set Current Day/Time Wake Set Program Leave Return Sleep Hold Temp Day Heat/Cool Settings System Fan Cool Daylight Time Copy M14653 69-1400—1 10 DELUXE PROGRAMMABLE THERMOSTAT 4. Press increase s or decrease t key to adjust temperature settings. Setting Time Run Program Set Current Day/Time Wake Set Program Leave Return Sleep Hold Temp Day Heat/Cool Settings System Fan Cool Daylight Time Copy M14654 NOTE: The display changes from the setpoint to the room temperature after approximately 3 seconds. Press Run Program to cancel the Hold and to return to the program. Changing Temperature Setting Until a Designated Day and Period 1. Press Hold Temp twice. Setting Hold for Time Set Program Wake Leave Return Sleep System Heat Hold Temp Run Program Set Current Day/Time Days Wake Heat Fan Auto Hold Temp Day Heat/Cool Settings System Fan Daylight Time Copy M14655 2. Press Time s or Time t until the desired number of days is displayed (1 to 255 days). (Example: 18 = Hold will override the daily programs for 18 days) Time Setting Hold for Sleep System Heat Time Run Program Set Current Day/Time Wake Set Program Leave Return Days Wake Heat Fan Auto Hold Temp Day Heat/Cool Settings System Fan Daylight Time Copy M14656 3. Press Wake, Leave, Return or Sleep to select the period the program will start. Auto: The thermostat automatically changes between heating and cooling operation, depending on the indoor temperature (select models). Fan settings control the system fan as follows: On: Fan operates continuously. Auto: Fan operates with equipment. Time Run Program Set Current Day/Time Wake Set Program Leave Return Sleep Hold Temp Day Heat/Cool Settings System System Fan Daylight Time Copy Fan M14625 69-1400—1 12 DELUXE PROGRAMMABLE THERMOSTAT Setting Temporary Fan Operation If your thermostat has a Fan key and this feature, press Fan until the desired fan operation is selected. This fan setting will be in effect until the next regularly scheduled period starts. Viewing and Resetting Timer Settings When the thermostat activates a timer, the thermostat flashes Filter until the timer resets. Reset the timer by pressing the key until the expired timer is displayed. Filter Days M20243 2. Press the Time s key to reset the timer. Filter Days M20244 3. Press the Run Program key. NOTE: You can view the number of days remaining at anytime by pressing the key three or four times. When conventional recovery is desired, call your service technician for assistance. Use the Adaptive Intelligent Recovery™ setting when you want to choose the exact time that the room reaches your comfort temperature. Use conventional recovery when you prefer to choose the exact time your heating or cooling system comes on to start recovery. 69-1400—1 16 DELUXE PROGRAMMABLE THERMOSTAT Saving Energy Across the United States and Canada • Save up to 30% in energy costs. The Deluxe Programmable Thermostat offers you complete comfort and a low cost easy way to save on your energy bills. • The energy saving percentages listed on the following maps are based on setting the program down in winter or up in summer for eight hours. • If the time period you choose for setback is longer, you could see even greater energy savings. The energy saving period must be at least two hours long to save any energy. The energy savings listed will be similar to the savings you can expect. TYPICAL ENERGY SAVINGS FOR REPRESENTATIVE CITIES IN THE U. S. AND CANADA Savings for Once-A-Day 10°F (5°C) decrease 30% Approximate percentage of energy cost savings 28% 26% 24% 22% 20% 18% 16% 14% 12% 10% 8% 6% 4% 2% Minneapolis St. Paul Montreal Ottawa Toronto Edmonton Regina Winnipeg Calgary Moncton North Bay Quebec St. John's Halifax Vancouver Buffalo Cleveland Milwaukee Denver Des Moines Omaha Salt Lake City Boston Chicago Detroit Pittsburgh Indianapolis Cincinnati Kansas City St. [. . . ] This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL CHRONOTHERM IV




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL CHRONOTHERM IV will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.