User manual HONEYWELL C7110A1010 DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL C7110A1010. We hope that this HONEYWELL C7110A1010 user guide will be useful to you.


HONEYWELL C7110A1010 DATASHEET: Download the complete user guide (562 Ko)

Manual abstract: user guide HONEYWELL C7110A1010DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] It detects unpleasant odors, tobacco smoke, and vapors emitted by such materials as furniture, carpets, paint, glue, etc. As proven in practice, this device detects those substances typically present in air having a poor quality, some of which may otherwise go undetected by room occupants, themselves. This sensor has proven itself in numerous applications over many years. [. . . ] The cover of the air quality sensor is fixed by a tab on the underside of the unit; to disassemble the cover and the sub-base, see Fig. To access all of the mounting holes, pull off the perforated cover, bend down slightly the tab to release the printed circuit board, and leverage the printed circuit board out (see Fig. 3). INCREASING OUTPUT VOLTAGE LIFT INCREASING GAS CONCENTRATION 2 Fig. Output voltage as a function of gas concentration INSTALLATION Wiring All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Wall module wiring can be sized from 16 to 22 AWG (1. 5 to 0. 34 mm2), depending on the application. The maximum length of wire from a device to a wall module is 1000 ft (305 m). Twisted pair wire is recommended for wire runs longer than 100 ft (30. 5 m). Keep wiring at least one ft (305 mm) away from large inductive loads such as motors, line starters, lighting ballast, and large power distribution panels. Run wall module wiring separately from 50 Vac or greater power wiring. 1 PRESS Fig. a) Mount the sensor onto the wall outlet box, or b) bore wall holes as specified in Fig. 3 and mount the wall module with appropriate screws. CAUTION Low Voltage Equipment. The 24 Vac power source for this product must be a safety isolating transformer. A transformer that is CE certified and meets the Low Voltage Device (LVD) requirements must be used in Europe for all installations of this product. EN0B-0644GE51 R1109A 2 C7110A1010 ROOM AIR QUALITY SENSOR 1 100 86 OUTPUT VOLTAGE 60 Y 24V 24V~ OFFSET TAB TO RELEASE PCB 68 97 2 104 99 30 Fig. Dimensions and mounting holes (mm) IMPORTANT Screw-type terminal blocks are designed to accept no more than one 16 AWG (1. 5 mm2) conductor. After re-inserting the printed circuit board and the perforated plate, connect the wires to the terminal block as follows: a) Strip 3/16 in. Adjust the trimming potentiometer (see section "Adjusting the Offset Signal"). When the air quality deteriorates, the voltage of the output signal will rise. Adjusting the Offset Signal After mounting the device, the output signal should be adjusted in accordance with expected ambient conditions and individual preferences. The output signal is adjusted using the trimming potentiometer located on the sensor board (see Fig. [. . . ] NOTE: When first operating the device or after the device has been powered down for more than 4 weeks (e. g. , during storage), the output signal may vary during the first 48 hours of operation. In this case, you should verify the output signal after 48 hours of operation. OUTPUT VOLTAGE (V) 10 5 ROOM UNOCC. , SENSOR IDLING Fig. Dynamic behavior of the C7110A1010 Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z. A. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL C7110A1010




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL C7110A1010 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.