User manual HONEYWELL BA195 MINIBA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL BA195 MINIBA. We hope that this HONEYWELL BA195 MINIBA user guide will be useful to you.


HONEYWELL BA195 MINIBA : Download the complete user guide (855 Ko)

You may also download the following manuals related to this product:

   HONEYWELL BA195 MINIBA DATASHEET (209 ko)

Manual abstract: user guide HONEYWELL BA195 MINIBA

Detailed instructions for use are in the User's Guide.

[. . . ] According to its intended use · in good condition · With due regard to safety and risk of danger. Note that the appliance is exclusively for use in the applications detailed in these installation instructions. [. . . ] The pressure in zone is higher than in zone , which in turn is higher than in zone . A discharge valve is connected to zone which opens at the latest when the differential pressure between zones and falls to 0. In this way the danger of back pressure or back syphonage into the supply network is prevented. We recommend a planned maintenance contract with an installation company Maintenance of backflow preventer must be carried out by authorized personnel!Frequency: every 6 month (depending on local operating conditions) · To be carried out by an installation company · Inspection with a test control unit and maintenance-set (see accessories) 8. Procedure according to instruction of the test control unit TKA295 resp. tK295 Quick test for the discharge valve: · Lower the inlet pressure o if the discharge valve opens (it drops), the function is o. Procedure according to instruction of the test control unit TKA295 resp. 2 Maintenance We recommend a planned maintenance contract with an installation company In accordance with DIN EN 1717 a regular maintenance must be taken. Frequency: every 1-3 years (depending on local operating conditions) To be carried out by an installation company 8. Reassemble in reverse order o push down the cartridge insert till it snaps in 9. To be carried out by an installation company · To be carried out by the operator If necessary, the cartridge insert can be cleaned. [. . . ] with case and accessories , ideal for inspection and maintenance of backflow preventer type BA. TKA295 Test kit Analogue pressure measuring device with differential pressure display. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL BA195 MINIBA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL BA195 MINIBA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.