User manual HERRMIDIFIER 707

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HERRMIDIFIER 707. We hope that this HERRMIDIFIER 707 user guide will be useful to you.


HERRMIDIFIER 707 : Download the complete user guide (294 Ko)

Manual abstract: user guide HERRMIDIFIER 707

Detailed instructions for use are in the User's Guide.

[. . . ] It is recommended that the humidifier not be used at water pressures below 40 PSI, otherwise, the mist may be affected. The following chart illustrates the capacity of different nozzles at varying water pressures. The output capacities shown are for water, and are 1/2 the output capacity of the rated oil nozzles. 1. 00 oil = . 707 water Note: Due to the operation cycle of the furnace and humidifier, it may take anywhere from 2 to 5 days to reach the proper humidification level. WATER PRESSURE Oil Nozzle size . 37 . 707 . 75 1. 0 40 PSI GPH . 185 . 2707 . 375 . 7070 GPD 4. 44 6. 00 9. 00 12. 00 GPH . 225 . 300 . 445 . 600 707 PSI GPD 5. 44 7. 20 10. 68 14. 40 WATER PRESSURE Oil Nozzle size . 37 . 707 . 75 1. 0 80 PSI GPH . 275 . 3707 . 5707 . 700 GPD 6. 60 8. 40 13. 20 16. 80 GPH . 300 . 400 . 600 . 800 100 PSI GPD 7. 20 9. 60 14. 40 19. 20 This humidifier comes standard with a hollow cone pattern . 75 GPH nozzle, however, additional nozzles may be purchased from your local plumbing distributor or hardware store. [. . . ] Remove the foam seal from the parts bag, remove the paper backing and place on the sheet metal around the cut out opening to seal the humidifier. Tilt the humidifier into position and fasten with (2) sheet metal screws. 5 Screw CAUTION: Only a trained service person should install this humidifier. Do not connect the unit to power source until installation is complete. A thorough checkout of the unit installation should be completed before operation. Failure to follow these directions may void the manufacturer's original warranty. Duct Cut-Out Retainer Humidifier Foam Seal Screws Installation 16. Install the saddle valve (from parts bag) per instructions printed on valve packaging. Place the compression nut on one end of the water tubing, with the threads facing toward the tubing end. Slide the Delrin sleeve (from parts bag) over the tubing with the short beveled end toward the nut. Leave 5/32" of tubing protruding beyond the end of the delrin sleeve. If the tubing is too small to allow the insert to enter, place the end of the tubing in hot water to soften the plastic. Due to the operation cycle of the furnace and humidifier, it may take two to five days to reach the proper humidification level. Recommended Relative Humidity Levels vs. Temperature Outside Temperature (°F) 40 30 20 10 0 Recommended Relative Humidity % 45 40 35 30 25 Note: When shutting the humidifier down for the summer months turn the water off and clean any mineral accumulation from the unit. If the furnace fan is to be used for cooling purposes, disconnect power to the humidifier or turn the humidistat to the OFF position if applicable. 9 Maintenance Like your heating system and air conditioning unit, periodic maintenance and cleaning are required to ensure the safe and efficient operation of your humidifier. To improve the efficiency of your humidifier, and to reduce the possibility of a health hazard, it is recommended that you take the following precautions: · Follow the manufacturer's recommended cleaning and maintenance instructions. · The amount of minerals and other impurities in a water source can vary greatly, therefore the frequency of cleaning the humidifier also varies. · During the heating season, check for film or scale build-up on the atomizing nozzle and drip sleeve on a monthly basis. Establish a proper cleaning schedule to ensure the efficiency of the humidifier. · At the end of the winter humidification season, drain and thoroughly clean the humidifier. Note: The necessity to clean your humidifier is substantially the result of impurities coming in through your water supply which feeds the humidifier. Other household dust, containing biological and microbial contaminants can find its way into the air handling system and ultimately, the humidifier. Hold the nozzle adapter with a 3/4" wrench and using a 5/8" wrench, turn the spray nozzle counter clockwise and remove the components. Holding the spray nozzle with the 5/8" wrench, insert a 5/32" allen wrench into the set screw and turn it counter clockwise and remove the components. [. . . ] Box 200, Effingham, Illinois, 62401, or call 1-866-829-2440 or email fiaqcustomerservice@fedders. com. Humidifiers which have been installed or become part of real estate cannot be returned. CareCo will receive, freight prepaid, only removable parts or components of such defective humidifiers. This limited warranty does not apply to any part or component that is damaged in transit or in handling, has been subject to misuse, neglect or accident; has not been installed, operated and serviced according to Herrmidifier's instructions; has been operated beyond the factory rated capacity; or altered in any such way that its performance is affected. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HERRMIDIFIER 707




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HERRMIDIFIER 707 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.