User manual HEIDENHAIN ND 1200 V2.16

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HEIDENHAIN ND 1200. We hope that this HEIDENHAIN ND 1200 user guide will be useful to you.


HEIDENHAIN ND 1200 V2.16: Download the complete user guide (4533 Ko)

You may also download the following manuals related to this product:

   HEIDENHAIN ND 1200 V2.16 (4700 ko)
   HEIDENHAIN ND 1200 V2.16 (4703 ko)
   HEIDENHAIN ND 1200 V2.16 (4562 ko)
   HEIDENHAIN ND 1200 V2.16 (4525 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)
   HEIDENHAIN ND 1200 V2.17 QUICK REFERENCE GUIDE (2477 ko)

Manual abstract: user guide HEIDENHAIN ND 1200V2.16

Detailed instructions for use are in the User's Guide.

[. . . ] Operating Instructions ND 1200 QUADRA-CHEK Software Version 2. 16 English (en) 4/2009 ND 1200 Introduction 1 2 3 4 5 6 7 8 9 10 11 12 LCD screen Soft keys Measurement function keys Axis keys Mode selection keys Command keys Menu key Arrow cursor keys Fast track keys Numeric keypad Send key LCD On/Off key ND 1200 panel keys Panel keys are used to initiate feature measurements, apply tolerances, send reports of measurement results and configure operational parameters. Panel function key Soft keys: Functions change in support of the activities displayed on the LCD. Feature measurement types include points, lines, circles distances, angles, skew alignments and Measure Magic. Axis keys: Select axes for zeroing or presetting datums prior to measurements. [. . . ] All feature measurement data is sent in as comma separated variables without tolerance data. All feature measurement data is sent in as tab separated variables without tolerance data. No data are sent. Sending reports Reports can be sent at any time. To send a report: U Press the feature SEND key. Reports can also be sent: By including the send function in a program When the Print setup screen is configured to send when an edge is recognized When the Measure setup screen is configured to send in response to tolerance test results By pressing a hot key configured in the Hot Keys setup screen to send 72 1 Operation Scale errors Only input encoder scale errors are reported by the ND 1200. Scale errors are indicated by the presence of graphic bars across the DRO screen instead of numbers. Scale errors can be caused by a few conditions shown in this table: Possible cause Damaged encoder reader head Misaligned encoder reader head Electrical noise on the encoder input Corrective action Repair or replace the encoder. Recalibrate the reader head. Verify that the earth ground provided by the ND 1200 power source is in good condition and is connected to the power system ground. Verify that the encoder cable is shielded and that the shield is connected to ground at the ND 1200 end. Verify that the reader head is not generating electrical noise. Stage (encoder) velocity too high Faulty encoder input connection Restrict stage velocity. If the velocity required for error-free operation is slow, recalibrate the reader head. Repair or replace the encoder cable or seek the assistance of your Metronics distributor. ND 1200 QUADRA-CHEK 73 1. 10 Error Indications 1. 10 Error Indications 1. 10 Error Indications 74 1 Operation Installation, Setup and Specifications 2. 1 ND 1200 Shipment Contents 2. 1 ND 1200 Shipment Contents The contents of your ND 1200 shipment are described below. Repackaging instructions are also included for return shipments for distributors and OEM customers that are configuring a ND 1200 and shipping it to an end-user. Save the ND 1200 packaging materials for possible return shipment or shipment to an end-user. Items included with the ND 1200 The following items are shipped with the ND 1200: ND 1200 instrument Mounting stand hardware Power cord 2-D demo part ND 1200 Quick reference guide Warranty registration card Optional items possibly included The following items might be shipped with your ND 1200, depending on the options and accessories ordered at the time of purchase: Remote foot switch Remote keypad Optical edge detector cables and cable holder ND 1200 Protective cover QC-Wedge communication software If any components were damaged in shipment, save the packaging materials for inspection and contact your shipping agent for mediation. Contact your Metronics distributor or OEM for replacement parts. 76 2 Installation and Specifications When shipping the ND 1200 on to an end-user, repackage all ND 1200 components in the original packaging as received from the factory. The original packaging must be duplicated and the LCD must be inserted face-up to prevent damage to the screen. It is not necessary to ship the mounting stand and hardware with the instrument when returning the ND 1200 for service. Replace the contents of the cardboard box insert if shipping the ND 1200 on to an end-user. The cardboard box can be empty if returning the ND 1200 to the factory for service. Repackage the instrument, foam and cardboard box insert as originally shipped from the factory. Replace the warranty card and slip sheets originally found at the top of the carton when shipping on to an end-user. The "Before you begin" slip sheet should be inserted last. ND 1200 QUADRA-CHEK 77 2. 1 ND 1200 Shipment Contents Repackaging the ND 1200 2. 2 Hardware Installation 2. 2 Hardware Installation The ND 1200 is easy to install in a variety of measurement applications. This section describes how to install the ND 1200 hardware. Assembling the mounting stand The ND 1200 is secured to the swivel slots of the mounting stand by a shoulder screw, a cap screw and associated washers. Assemble the ND 1200 to the mounting stand as shown, and then tighten the cap screw (5) and washers (3 & 4) so that the ND 1200 will be secure when adjusted to the desired tilt position. U U U Tighten the shoulder screw (1). [. . . ] The new file is automatically given the next number in a sequence that begins with the number specified in the Cur Auto No data field. 2. 3 Software setup Audio configuration The ND 1200 can be configured to generate a sound in response to certain measurement activities and results. Sounds screen The Sounds screen contains choice fields for enabling or disabling audio beeps in response to: Warning: Any warning shown on the screen Point entry: When a point is entered during measurement Begin measure: Immediately prior to a measurement during a program execution Good result: When a measurement passes all tolerance tests Failed result: When a measurement fails a tolerance test Excess form: Form error in excess of factory default values. To enable an audio alert: U U Press MENU/SETUP to display the setup menu and then highlight the Sounds menu item. Highlight the desired audio alert choice field and then press the SIMPLE soft key to enable the alert or press the NONE soft key to disable it. The volume of all audio responses can be changed simultaneously from silence to loud. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HEIDENHAIN ND 1200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HEIDENHAIN ND 1200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.