User manual HATCO PMG-100-200M-0805(2)

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HATCO PMG-100-200M-0805(2). We hope that this HATCO PMG-100-200M-0805(2) user guide will be useful to you.


HATCO PMG-100-200M-0805(2) : Download the complete user guide (706 Ko)

Manual abstract: user guide HATCO PMG-100-200M-0805(2)

Detailed instructions for use are in the User's Guide.

[. . . ] POWERMITE® GAS BOOSTER HEATER INSTALLATION, OPERATING, SERVICE AND PARTS MANUAL MODEL: PMG-100 & PMG-200 I&W #07. 05. 055. 00 WATER HEATERS FOR OTHER THAN RECREATIONAL VEHICLE INSTALLATION ONLY CHAUFFE-EAU POUR INSTALLATION AUTRE QUE DANS DES VÉHICULES DE LOISIR UNIQUEMENT WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. AVERTISSEMENT: Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d'incendie ou d'explosion ou pour éviter tout dommage matériel, toute blessure ou la mort. - Ne pas entreposer ni utiliser d'essence ou ni d'autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil. - QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ: · Ne pas tenter d'allumer d'appareil. [. . . ] This appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3. 5 kPa). Dissipate test pressure from the gas supply line before re-connecting the heater and its manual shut-off cock to the gas supply line. The heater and its gas connections shall be leak tested before placing the appliance in operation. Incoming Gas Pressure Specifications Inches Water Column Gas Type Natural Propane/LP Minimum 5. 0 11. 0 Maximum 10. 5 13. 0 The maximum inlet gas pressure must not exceed the values shown above. The minimum gas pressure listed is for the purposes of input adjustment. The manifold inside the heater is provided with a pressure tap to measure the gas pressure. The chart below lists the proper pressure amounts at the manifold pressure tap when testing. Operating Pressure Specifications at Manifold Inches Water Column At Pressure Tap Gas Type Natural Propane/LP High Burn 3. 5 10. 0 See Figure 6 for hook-up location and pressure tap location. 17 Form No. PMG-100/200M-0805 INSTALLATION ELECTRICAL Components SUPPLIED WITH UNIT · 7/8" Hole Plugs OPTIONAL WITH UNIT None SUPPLIED BY INSTALLER · 120 VAC, 60 Hz, 15 Amp Single Phase Service · Electrical Ground The Hatco Gas Booster Heater operates on 120 VAC, 60 Hz, 15 amp, single phase service. WARNING If an external electrical source is utilized, the appliance, when installed, must be electrically grounded in accordance with local codes, or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, and CSA C22. 1, Electrical Code. Electrical Connections To connect the field wiring to the booster heater: 1. Remove the front access panel from the unit by lifting up on the front panel and pulling upper edge away from unit until it clears the lower edge. Open electrical enclosure at the lower left corner of the base by removing two screws. Bring power leads from a properly sized fused disconnect switch or circuit breaker through 7/8" hole provided on lower left hand side or bottom of base. An equipment grounding conductor must be properly connected to the green terminal block. (See Figure 7. ) CAUTION To avoid damage to both the pump and heater assembly, do not turn on the power switch to the heater until the installation is complete and the booster water tank is filled with water and all air in the system has been vented through the dishwasher rinse nozzles. 1. PMG-100/200M-0805 18 INSTALLATION VENTING The PMG-100 and PMG-200 may be vented by two methods, both of which have been tested for compliance with national safety standards for gas water heaters. The installation of the venting system must comply with local codes and in the absence of local codes, in accordance with the National Fuel Gas Code and the guidelines in this manual. Before installing any method of venting you should contact the local code authority of your gas supplier to make sure that the final installation will be acceptable to the authorities having jurisdiction. The proper method of venting a power vented gas appliance is too complicated to cover in this manual and is explained in detail in the National Fuel Gas Code. Before installing the venting system the person or agency making the installation must be familiar and experienced with the guidelines of the National Fuel Gas Code. The temperature of the flue gases from this booster water heater operates at approximately 225°F to 275°F (107°C to 135°C). The two methods that have been tested for compliance with the national safety standards are: 1. [. . . ] Hatco reserves the right to accept or reject any such claim in whole or in part. Hatco will not accept the return of any Product without prior written approval from Hatco, and all such approved returns shall be made at Buyer's sole expense. HATCO WILL NOT BE LIABLE, UNDER ANY CIRCUMSTANCES, FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR COSTS OR LOST PROFITS RESULTING FROM THE USE OF OR INABILITY TO USE THE PRODUCTS OR FROM THE PRODUCTS BEING INCORPORATED IN OR BECOMING A COMPONENT OF ANY OTHER PRODUCT OR GOODS. Form No. PMG-100/200M-0805 HATCO AUTHORIZED PARTS DISTRIBUTORS ALABAMA Jones McLeod Appl. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HATCO PMG-100-200M-0805(2)




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HATCO PMG-100-200M-0805(2) will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.