User manual HATCO FSHACM-0106(1)

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HATCO FSHACM-0106(1). We hope that this HATCO FSHACM-0106(1) user guide will be useful to you.


HATCO FSHACM-0106(1) : Download the complete user guide (728 Ko)

Manual abstract: user guide HATCO FSHACM-0106(1)

Detailed instructions for use are in the User's Guide.

[. . . ] FLAV-R-SAVOR ® Heated Air Curtain Cabinets FSHAC & FSHACH Series Installation & Operating Manual I&W #07. 05. 164. 00 This manual contains important safety information concerning the maintenance, use and operation of this product. Failure to follow the instructions contained in this manual may result in serious injury. If you're unable to understand the contents of this manual, please bring it to the attention of your supervisor. Do not operate this equipment unless you have read and understood the contents of this manual. Este manual contiene importante información sobre seguridad concerniente al mantenimiento, uso y operación de este producto. [. . . ] Attach legs by turning leg clockwise on the bottom of the unit (See Figure 6). Position Cabinet upright and move to the desired operating location. Form No. FSHACM-0106 6 INSTALLATION PLUMBING (Humidified Models FSHACH-2, FSHACH-2PT and FSHACH-3 Only) WARNING For proper plumbing installation conforming to local plumbing codes, consult a licensed plumbing contractor. CAUTION To assure proper operation and to avoid damage to the unit, the incoming water supply pressure must be at least 35 psi (241 kPa) and not to exceed 80 psi (552 kPa). CAUTION To assure proper operation and to avoid damage to the unit, the incoming water supply temperature must not exceed 140°F (60°C). CAUTION Water Quality Requirements - Incoming water in excess of 3. 0 grains of hardness per gallon (GPG) (. 75 grains of hardness per liter) must be treated and softened before being used. Water containing over 3. 0 GPG (. 75 GPL) will decrease the efficiency and reduce the operating life of the unit. CAUTION To assure proper operation and extend the life of humidified models utilizing the auto-fill system, the water filter cartridge must be installed in the water supply line. De-ionized water will greatly shorten the life of the water heating elements and plumbing components. Auto-Fill Installation NOTE: Water inlet and drain connections must be made with flexible hose. If required, a ball valve or gate valve, line strainer, union(s) and vacuum breaker or other anti-siphon device must be supplied by plumber or installer. Materials required for installation include plumbing tape or pipe sealant, and appropriate fittings for application. Assemble fittings to filter cartridge using plumbing tape or pipe sealant. FSHACM-0106 Water Flow Arrow Water Supply Outlet Water Supply Inlet Figure 7. Plumbing Connections NOTE: Install filter cartridge with flow arrow towards the equipment. NOTE: Flush new filter cartridge with water for five minutes before use. INSTALLATION See MAINTENANCE section for Filter Cartridge Replacement. A drain connection is located inside the cabinet cavity for manually draining the water reservoir. Drain Outlet on Humidified Units OPERATION WARNING Some exterior surfaces on the unit will get hot. WARNING To prevent any injury, discontinue use if power cord is frayed or worn. For safe and proper operation the unit must be located indoors where the ambient air temperature is a minimum of 70°F (21°C) and a maximum of 85°F (29°C). FSHAC CONTROL PANEL 1. Plug unit into an electrical outlet of the correct voltage, size and plug configuration. Set Air temperature by pushing TEMPERATURE button once to display "tsp. " Push button again to display current temperature setting. [. . . ] HATCO WILL NOT BE LIABLE, UNDER ANY CIRCUMSTANCES, FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR COSTS OR LOST PROFITS RESULTING FROM THE USE OF OR INABILITY TO USE THE PRODUCTS OR FROM THE PRODUCTS BEING INCORPORATED IN OR BECOMING A COMPONENT OF ANY OTHER PRODUCT OR GOODS. 13 Form No. FSHACM-0106 HATCO AUTHORIZED PARTS DISTRIBUTORS ALABAMA Jones McLeod Appl. Phoenix 602-252-0402 CALIFORNIA Industrial Electric Huntington Beach 714-379-7100 INDIANA GCS Service Indianapolis IOWA Electric Motor Service Co. Davenport 319-323-1823 Goodwin Tucker Group Des Moines 515-262-9308 KENTUCKY GCS Service Louisville LOUISIANA Chandlers Parts & Service Baton Rouge 225-272-6620 MARYLAND Electric Motor Service Baltimore 410-467-8080 GCS Service Silver Spring MASSACHUSETTS Ace Service Co. , Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HATCO FSHACM-0106(1)




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HATCO FSHACM-0106(1) will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.