User manual HARVIA HGS11

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HARVIA HGS11. We hope that this HARVIA HGS11 user guide will be useful to you.


HARVIA HGS11 : Download the complete user guide (3526 Ko)

You may also download the following manuals related to this product:

   HARVIA HGS11 (3424 ko)
   HARVIA HGS11 (3424 ko)
   HARVIA HGS11 (3139 ko)
   HARVIA HGS11 (3139 ko)
   HARVIA HGS11 (3375 ko)
   HARVIA HGS11 (3375 ko)
   HARVIA HGS11 (3099 ko)
   HARVIA HGS11 (3099 ko)
   HARVIA HGS11 (2944 ko)
   HARVIA HGS11 (2944 ko)
   HARVIA HGS11 (3050 ko)
   HARVIA HGS11 (3050 ko)

Manual abstract: user guide HARVIA HGS11

Detailed instructions for use are in the User's Guide.

[. . . ] Open the discharge valve, let the reservoir drain and close the valve before turning the device on. start the steam generator by pressing the I/O button on the control panel. When the device starts, the top row of the display will show the set temperature and the bottom row will show the set on time for five seconds. In a Multidrive system, the control panel will first connect with the steam generators that are ready for use. [. . . ] It is recommended to wash the fragrance container between uses, especially when using different fragrances. Lighting The lighting of the steam room can be set up so that it can be controlled from the steam generator control panel. Ventilation If there is a fan installed to the steam room, it can be connected to the steam generator. In this case the ventilation can be controlled from the steam generator control panel. All other maintenance must be left to professional maintenance personnel. Steam generators in community, institution and such use must be serviced thoroughly at least twice a year (checking and cleaning the reservoir, heating elements and the water level sensor). Water level Sensor Maintenance Open the water level sensor service hatch, disconnect the sensor cables and lift the sensor out (notice the order of the wires: greenH, redL, yellowC). If there are lime precipitates or other impurities on the tips of the water level sensor's pins (figure 5), the tips must be cleaned with sandpaper. If the plastic coating on the pins is damaged, the water level sensor must be replaced. Lime, which may in time block the internal parts of the steam generator. The amount of lime in water (water hardness) and thus the need for decalcification varies from region to region. If using other materials for the decalcification, follow the instructions in the packaging. Turn it off from the main switch (underneath the steam generator, see figure 10). Pour the citric acid solution in to the water reservoir and put the water level sensor with its wires back in. If the memory for power failures is on (see figure 3), the steam generator will start without pushing the I/O button. Turn the steam generator on with the I/O button and leave it on for one minute. Turn the steam generator off with the I/O button, empty the water reservoir and close the discharge valve. Turn the steam generator on with the I/O button and leave it on for 3 minutes. Turn the steam generator off with the I/O button and leave it off for 2 minutes. Effect Wirkung Colour, taste, precipitates in the steam generator Farbe, Geschmack, Ablagerungen im Dampfgenerator Colour, odour, taste, precipitates in the steam generator Farbe, Geruch, Geschmack, Ablagerungen im Dampfgenerator Precipitates in the steam generator Ablagerungen im Dampfgenerator recommendation Empfehlung < 12 mg/l < 0, 2 mg/l Mn: < 0, 05 mg/l Ca: < 100 mg/l Forbidden to use Darf nicht verwendet werden Forbidden to use Darf nicht verwendet werden 812 l/min Chlorinated water Health risk Gechlortes Wasser Gesundheitsschädlich Seawater Salzwasser Flow rate in the incoming water pipe (measuring: let the water run from the incoming pipe for one minute and measure the amount of water) Durchfluss in der Wasserzuleitung (Messung: Lassen Sie das Wasser eine Minute lang aus der Zuleitung laufen, und messen Sie die Wassermenge. Flow too slow: breaks in steam generation, E5 Flow too fast: water running from the steam pipe Durchfluss zu gering: Unterbrechung der Dampferzeugung, E5 Durchfluss zu hoch: Wasser läuft aus dem Dampfrohr Cleaning the Steam Nozzles The steam nozzles can be cleaned with mild soap solution. If there is a blockage in the steam nozzles and/ or pipes, the steam generator ill let the steam out from the overpressure valve. [. . . ] Multidrive Up to 5 steam generators can be connected in series so that they share the same control panel. You can connect additional sensors (1/steam generator) to enhance the temperature measuring accuracy and fault tolerancy of the system. Use numbers 04 if tap water is soft or numbers 59 if tap water is hard (see table 1). the maximum incoming water pressure for the water supply pipe is 1 MPa (10 bar). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HARVIA HGS11




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HARVIA HGS11 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.