User manual HANNA INSTRUMENTS PRIMO

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS PRIMO. We hope that this HANNA INSTRUMENTS PRIMO user guide will be useful to you.


HANNA INSTRUMENTS PRIMO : Download the complete user guide (413 Ko)

Manual abstract: user guide HANNA INSTRUMENTS PRIMO

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual Primo Series Dear Customer, Thank you for choosing a Hanna product. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. [. . . ] If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization number from the Customer Service department and then send it with shipping costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. ACCESSORIES HI 70031P HI 70032P HI 70039P HI 7031L HI 7032L HI 7039L 1413 µS/cm solution, 20 mL sachet, 25 pcs 1382 ppm solution, 20 mL sachet, 25 pcs 5. 00 mS/cm solution, 20 mL sachet, 25 pcs 1413 µS/cm solution, 500 mL bottle 1382 ppm solution, 500 mL bottle 5. 00 mS/cm solution, 500 mL bottle Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. ISTPRIMOR1 05/05 SPECIFICATIONS OPERATION ERROR CODES Error in calibration, wrong calibration solution or damaged probe. Low battery indication. Primo, Primo 2, Primo 5 Range Primo Primo 2 Primo 5 Resolution Primo Primo 2 Primo 5 1999 ppm (mg/L) 1999 ppm (mg/L) / 0. 0 to 60°C 1999 µS/cm 1 ppm (mg/L) 1 ppm (mg/L) / 0. 1°C 1 µS/cm Primo 1, Primo 3, Primo 4 Range Primo 1 Primo 3 Primo 4 Resolution Primo 1 Primo 3 Primo 4 1999 ppm (mg/L) 1999 ppm (mg/L) / 0. 0 to 60°C 10. 00 mS/cm 1 ppm (mg/L) 1 ppm (mg/L) / 0. 1°C 0. 01 mS/cm · Turn the meter on by pressing the ON/OFF button. · Immerse the probe in the sample to be measured, without exceeding the maximum immersion level. · To extend the batteries life, after 5 minutes of non-use the meter provides for auto-off. CALIBRATION · Switch the meter on. The required calibration solution value will start blinking on the display to indicate that the calibration mode has been entered. "1382" for Primo, Primo 1, Primo2, Primo3 "5. 00" for Primo 4, and "1413" for Primo 5 · Immerse the probe in the proper calibration solution without exceeding the maximum immersion level. · Once the display stops blinking, the meter is calibrated and ready for use. CE DECLARATION OF CONFORMITY Accuracy (@20°C/68°F) Primo ±2 % F. S. Calibration solution Primo Primo 2 Primo 5 Calibration Primo Primo 2 Primo 5 HI 70032 (1382 ppm) HI 70032 (1382 ppm) HI 70031 (1413 µS/cm) Automatic, at 1382 ppm Automatic, at 1382 ppm Automatic, at 1413 µS/cm Accuracy (@20°C/68°F) Primo 1 ±2 % F. S. Calibration solution Primo 1 Primo 3 Primo 4 Calibration Primo 1 Primo 3 Primo 4 HI 70032 (1382 ppm) HI 70032 (1382 ppm) HI 70039 (5. 00 mS/cm) Automatic, at 1382 ppm Automatic, at 1382 ppm Automatic, at 5. 00 mS/cm Temperature Compensation Automatic, 0 to 60°C (32 to 122°F); ß = 2%/°C Probe Direct, fixed Environment 0 to 50°C (32 to 122°F); RH max 95% Battery Type / Life 2 x 1. 5V / approx. 200 hours of continuous use auto-off after 5 minutes of non-use Dimensions / Weight 180 x 50 x 25 mm (7. 1x2. 0x1. 0") / 50 g (1. 8 oz. ) Temperature Compensation Automatic, 0 to 60°C (32 to 122°F); ß = 2%/°C Probe Fixed, with 1 m (3. 3') cable Environment 0 to 50°C (32 to 122°F); RH max 95% Battery Type / Life 2 x 1. 5V / approx. 200 hours of continuous use auto-off after 5 minutes of non-use Dimensioni/Peso 66 x 50 x 25 mm/ 50 g BATTERIES REPLACEMENT The "Eb" message on the LCD warns the user when the batteries have to be replaced. [. . . ] To avoid electrical shocks, do not use this instrument when voltage at the measurement surface exceeds 24Vac or 60Vdc. To avoid damage or burns, do not perform any measurement in microwave ovens. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS PRIMO




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS PRIMO will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.