User manual HANNA INSTRUMENTS HI 99171

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 99171. We hope that this HANNA INSTRUMENTS HI 99171 user guide will be useful to you.


HANNA INSTRUMENTS HI 99171 : Download the complete user guide (55 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 99171 (78 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 99171

Detailed instructions for use are in the User's Guide.

[. . . ] If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the problem. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. [. . . ] Note: The meter is provided with an acoustic signal feature, which can be disabled using the switch located in the battery compartment. Note: When the meter detects the absence of a temperature probe at its input, the Automatic Temperature Compensation is turned off, and the meter uses a default value of 25°C (77°F) for the temperature measurement and compensation. In this condition, the secondary LCD shows 25. 0°C (77. 0°F) blinking. When a probe is connected, the meter automatically returns to the ATC mode, the ATC tag is turned on, and the temperature is shown on the secondary display. Note: To clean the meter, do not use aggressive detergents. It is recommended to use water. pH MEASUREMENT & CALIBRATION · Make sure the meter has been calibrated before use. · If the probe is dry, soak it in HI 70300 storage solution for one hour to reactivate it. · Place the tip of the probe on the sample to be tested and wait until the symbol on the top left of the LCD is turned off. · The LCD shows the pH value (automatically compensated for temperature) on the primary LCD, while the secondary LCD shows the temperature of the solution. · After each measurement, it is recommended to perform a complete cleaning of the probe: use the suitable Cleaning solutions (see "Accessories" section) and clean the probe tip thoroughly to eliminate dirtiness and avoid crosscontamination. · When not in use, switch the meter OFF and clean the probe with the specific Cleaning solutions (see "Accessories" section) before storing it. pH calibration For better accuracy, frequent calibration of the instrument is recommended. In addition, the instrument must be recalibrated whenever: a) The pH electrode is replaced. · From normal mode, press and hold the ON/ OFF/MODE button until OFF on the secondary display is replaced by CAL. · The LCD enters the calibration mode, displaying "pH 7. 01 USE" (or "pH 6. 86 USE" if the NIST buffer set was selected). After 1 second the meter activates the automatic buffer recognition feature. If a valid buffer is detected, then its value is shown on the primary display, and REC appears on the secondary LCD. If no valid buffer is detected, the meter keeps the USE indication active for 12 seconds, and then replaces it with WRNG, indicating that the sample being measured is not a valid buffer. · For a single-point calibration with buffers pH 4. 01, 9. 18 or 10. 01, the meter automatically accepts the calibration when the reading is stable; the meter will show on the primary display the accepted buffer, with the message "OK 1" on the secondary display, and an audible signal is produced. After 1 second the meter automatically returns to the normal measuring mode. If a single-point calibration with buffers pH 7. 01 or 6. 86 is desired, then after the calibration point has been accepted the ON/OFF/MODE button must be pressed in order to return to the normal measuring mode. [. . . ] The secondary LCD displays CLR for 1 second, the meter resets to the default calibration and the "CAL" tag on the LCD disappears. METER SETUP Setup mode allows the selection of the temperature unit and of the pH buffer set. To enter the Setup mode, press and hold the ON/ OFF/MODE button until CAL on the secondary display is replaced by TEMP and the current temperature unit (E. g. After the temperature unit has been selected, press ON/OFF/MODE to enter the buffer set selection mode; press ON/OFF/MODE twice to return to the normal measuring mode. · to change the calibration buffer set, after setting the temperature unit, the meter will show the current buffer set: "pH 7. 01 BUFF" (for 4. 01/ 7. 01/10. 01) or "pH 6. 86 BUFF" (for 4. 01/6. 86/ 9. 18). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 99171




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 99171 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.