User manual HANNA INSTRUMENTS HI 991003

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 991003. We hope that this HANNA INSTRUMENTS HI 991003 user guide will be useful to you.


HANNA INSTRUMENTS HI 991003 : Download the complete user guide (63 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 991003 (89 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 991003

Detailed instructions for use are in the User's Guide.

[. . . ] If under warranty, report the model number, date of purchase, serial number and the nature of the problem. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. [. . . ] In this condition, the secondary LCD shows 25. 0°C (77. 0°F) blinking. When a probe is connected, the meter automatically returns to the ATC mode, the ATC tag is turned on, and the temperature is shown on the secondary display. pH MEASUREMENT & CALIBRATION · Make sure the meter has been calibrated before use. · If the probe is dry, soak it in HI 70300 storage solution for one hour to reactivate it. · Stir briefly and wait until the symbol on the top left of the LCD is turned off. · The LCD shows the pH value (automatically compensated for temperature) and the temperature of the solution. · If measurements are taken in different samples successively, rinse the probe tip thoroughly to eliminate cross-contamination. After cleaning, rinse the probe tip with some of the sample to be measured. pH calibration · Press and hold the ON/OFF/MODE button until OFF on the secondary display is replaced by CAL. The LCD enters the calibration mode, displaying "pH 7. 01 USE" (or "pH 6. 86 USE" if the NIST buffer set was selected). After 1 second the meter activates the automatic buffer recognition feature. If a valid buffer is detected, then its value is shown on the primary display, and REC appears on the secondary display. If no valid buffer is detected, the meter keeps the USE indication active for 12 seconds, and then it replaces it with WRNG, indicating that the sample being measured is not a valid buffer. · For a single-point calibration with buffers pH 4. 01, 9. 18 or 10. 01, the meter automatically accepts the calibration when the measurement is stable; the meter will show on the primary display the accepted buffer, with the message "OK 1" on the secondary display, and an audible signal is produced. If a single-point calibration with buffers pH 7. 01 or 6. 86 is desired, then after the calibration point has been accepted the ON/OFF/MODE button must be pressed in order to return to the normal measuring mode. After the button is pressed, the meter shows "7. 01" (or "6. 86") "OK 1", and an audible signal is produced. After 1 second, the meter automatically returns to the normal measuring mode. · For a two-point calibration, place the probe in pH 7. 01 (or pH 6. 86) buffer. After the calibration point has been accepted, the "pH 4. 01 USE" message appears. The message is held for 12 seconds, unless a valid buffer is recognized. If a valid buffer (pH 4. 01, pH 10. 01 or pH 9. 18) is detected, then the meter completes the calibration procedure. [. . . ] The offset value is the reading of the electrode immersed in pH7 buffer (@25°C/77°F). If this reading is outside the range ±40 mV, the electrode is considered "poor" and it is recommended to replace it with a new one. The slope value of the electrode is the difference between readings in pH7 and in pH4 buffers. When it reaches the value of about 150 mV, the electrode is considered "poor", and it is recommended to replace it with a new one. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 991003




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 991003 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.