User manual HANNA INSTRUMENTS HI 98509-01

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98509-01. We hope that this HANNA INSTRUMENTS HI 98509-01 user guide will be useful to you.


HANNA INSTRUMENTS HI 98509-01 : Download the complete user guide (108 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 98509-01 (213 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 98509-01

Detailed instructions for use are in the User's Guide.

[. . . ] Checktemp-Dip HI 98509-01 (Checktemp-Dip) C: Celsius Model HI 98510-01 (Checktemp-Dip) F: Fahrenheit Model SPECIFICATIONS: Range ºC ºF Resolution ºC ºF Accuracy ºC ºF -20 to 100. 0 & -60. 0 to 0. 0°C -4. 0 to 199. 9ºF & 200 to 212ºF 0. 1°C 0. 1°F (-4. 0 to 199. °F) 1°F (200 to 212°F) ±0. 5°C (-20 to 50°C) ±0. 9°C (outside) ±0. 9°F (-4 to 122°F) ±2°F (outside) Recommendations for Users: Before using this product, make sure that it is entirely suitable for the environment in which it is used. [. . . ] 3, 000 hours of continuous use Dimensions 106 x 58 x 19 mm (4. 2 x 2. 2 x 0. 7") Weight 80 g (2. 8 oz. ) Probe Stainless steel probe with 3 meter (10') cable Visit our Internet Home Page: www. hannainst. com Manufacturers since 1978 Checktemp-Dip OPERATION: · Turn Checktemp-Dip on. · Dip the probe in the · RUN ON TEST 0°C/32°F OFF sample. An immersion level of at least 4 cm (1 ½") is recommended. · Wait for a few seconds for the display to stabilize and switch the meter off when not in use. · Variations in readings or fading display can indicate a weak battery. BATTERY 1. 5V AAA Even though Checktemp-Dip can reach 100ºC, prolonged measurements at high temperatures will reduce the sensors life dramatically. Ideally operate in the -20 to 50ºC (-4 to 120ºF) range. BATTERY REPLACEMENT: When Checktemp-Dip cannot be switched on or the display fades, remove the two screws, open the battery cover and change the RUN ON RUN ON CALIBRATION CHECK SWITCH: TEST 0°C/32°F OFF TEST 0°C/32°F OFF · Checktemp-Dip is not suitable for continuous measurement (in-line, especially at high temperatures) and should only be used for spot checks. Move the Cal-check switch down. [. . . ] Battery should only be replaced in a safe area using an alkaline 1. 5V AAA type battery. ISTRCKTDIPR2 05/02 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98509-01




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 98509-01 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.