User manual HANNA INSTRUMENTS HI 98311

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98311. We hope that this HANNA INSTRUMENTS HI 98311 user guide will be useful to you.


HANNA INSTRUMENTS HI 98311 : Download the complete user guide (161 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 98311 (226 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 98311

Detailed instructions for use are in the User's Guide.

[. . . ] These instruments are in compliance with the directives. FUNCTIONAL DESCRIPTION Range SPECIFICATIONS Temperature: 0. 0 to 60. 0°C / 32. 0 to 140. 0°F EC: TDS: Resolution Temp: EC/TDS: 0 to 3999 µS/cm (HI 98311) 0. 00 to 20. 00 mS/cm (HI 98312) 0 to 2000 ppm (HI 98311) 0. 00 to 10. 00 ppt (HI 98312) 0. 1°C / 0. 1°F 1 µS/cm ; 1 ppm (HI 98311) 0. 01 mS/cm ; 0. 01 ppt (HI 98312) Accuracy (@20°C/68°F) PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully. If any damage has occurred during shipment, immediately notify your Dealer or the nearest Hanna Customer Service Center. Each meter is supplied with: · HI 73311 EC/TDS probe · HI 73128 Probe removal tool · 4 x 1. 5V batteries Note: Conserve all packing material until the instrument has been observed to function correctly. Any defective item must be returned in its original packing. Temp: EC/TDS: Temp: EC/TDS: ±0. 5°C / ±1°F ±2% f. s. [. . . ] A low battery symbol warns the user when the batteries are to be replaced. In addition the Battery Error Prevention System (BEPS) avoids erroneous reading caused by low voltage level by turning the meter off. The HI 73311 EC/TDS probe, supplied with the meter, is interchangeable and can be easily replaced by the user. The stainless steel encapsulated temperature sensor facilitates faster and more accurate temperature measurement and compensation. SET/HOLD button 1. Measuring units for primary display Recommendations for Users Before using this product, make sure that it is entirely suitable for the environment in which it is used. Operation of this instrument in residential areas could cause unacceptable interferences to radio and TV equipment. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. To avoid electrical shock, do not use this instrument when voltages at the measurement surface exceed 24 VAC or 60 VDC. To avoid damages or burns, do not perform any measurement in microwave ovens. ISTR98311R2 03/03 OPERATIONAL GUIDE To turn the meter on and to check battery status Press and hold the /MODE button for 2-3 seconds. All the used segments on the LCD will be visible for a few seconds, followed by a percent indication of the remaining battery life (E. g. The measurements should be taken when the stability symbol on the top left of the LCD disappears. The EC (or TDS) value automatically compensated for temperature is shown on the primary LCD while the secondary LCD shows the temperature of the sample. To change the temperature unit To change the temperature unit (from °C to °F), from measurement mode, press and hold the /MODE button until TEMP and the current temperature unit are displayed on the lower portion of the LCD (E. g. Use the SET/HOLD button to change the temperature unit, and then press the /MODE button twice to return to the normal measuring mode. To freeze the display Press the SET/HOLD button for 2-3 seconds until HOLD appears on the secondary display. To turn the meter off Press the /MODE button while in normal measuring mode. Notes: · Before taking any measurement make sure the meter has been calibrated. · If measurements are taken in different samples successively, rinse the probe thoroughly to eliminate cross-contamination; and after cleaning, rinse the probe with some of the sample to be measured. CALIBRATION For better accuracy, frequent calibration of the instrument is recommended. In addition, the instrument must be recalibrated whenever: a) The EC/TDS probe is replaced. To change the EC/TDS coversion factor (CONV) and the temperature compensation coefficient (BETA) · From measurement mode, press and hold the / MODE button until TEMP and the current temperature unit are displayed on the lower LCD (E. g. [. . . ] The meter will be reset to the default calibration. PROBE MAINTENANCE The EC/TDS probe can be easily replaced by using the supplied tool (HI 73128). Insert the tool into the probe cavity as shown below. BATTERY REPLACEMENT The meter displays the remaining battery percentage every time it is switched on. When the battery level is below 5%, the - + symbol on the bottom left of the LCD lights up to indicate a low battery condition. If the battery level is low enough to cause erroneous readings, the meter shows "0%" and the Battery Error Prevention System (BEPS) will automatically turn the meter off. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98311




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 98311 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.