User manual HANNA INSTRUMENTS HI 98306

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98306. We hope that this HANNA INSTRUMENTS HI 98306 user guide will be useful to you.


HANNA INSTRUMENTS HI 98306 : Download the complete user guide (102 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 98306 (148 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 98306

Detailed instructions for use are in the User's Guide.

[. . . ] Conmet 2 Conductivity Meter with ATC* Specifications: - Range 0. 00 to 19. 99 mS/cm - Resolution 0. 01 mS/cm - Accuracy (@20°C / 68°F) ± 2% of Full Scale - Typical EMC Deviation ± 2% of Full Scale - Temp. Compensation Automatic 0°C to 50°C (32 to 122°F) - ATC Coefficient 1. 9% ±0. 15% per °C, referenced to 25°C (77°F) - Battery type 4 x 1. 5V ALKALINE - Battery life Approximately 150 hours - Operating temperature 0 to 50°C (32 to 122°F); 95% RH max. [. . . ] Because CONMET 2 has ATC, the displayed value is referenced to 25°C (77°F). · When introduced into a new sample, it is recommended to rinse the conductivity probe with the sample solution before the actual measurement. · To improve performance, clean the probe regularly by rinsing in alcohol for a few minutes. · Replace all 4x1. 5V batteries if the display becomes faint or disappears, or if the reading is unstable or unchanged. Battery replacement must only take place in a non hazardous area using the battery type specified in this instruction manual. This meter is in compliance with the CE directives. *Automatic Temperature Compensation Since the conductivity concentration changes as the temperature of the sample changes, ATC standardizes the value you read to 25°C (77°F). This feature eliminates the need to measure the temperature and calculate its effects on the conductivity concentration of the sample each time you perform a measurement. The results will be measurements that are consistent with the temperature variable eliminated. Calibration Instructions: · If readjustment is required, connect the conductivity probe to the meter without covering the calibration slot (Fig. · To readjust the CONMET 2, dip it into the calibration solution HI 7030 (12. 88 mS/cm @25°C/77°F). Wait 30 to 45 seconds for the reading to stabilize and, if necessary, correct the reading to "12. 88 " by slowly turning the calibration trimmer with the small screwdriver provided. The CONMET 2 Conductivity Meter is supplied in a rugged plastic carrying case with a 120 mL HI 7030 calibration solution bottle (Fig. Recommendations for Users: Before using this product, ensure that it is entirely suitable for the environment in which it is used. [. . . ] To avoid damages or burns, do not perform any measurement in microwave ovens. The instrument has to be switched off before cleaning the conductivity probe. ISCONMET2 03/96 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98306




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 98306 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.