User manual HANNA INSTRUMENTS HI 98280

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98280. We hope that this HANNA INSTRUMENTS HI 98280 user guide will be useful to you.


HANNA INSTRUMENTS HI 98280 : Download the complete user guide (1056 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 98280

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 9828 Multiparameter Meter with GPS w w w. h a n n a i n s t . c o m 1 Dear Customer, Thank you for choosing a HANNA instruments® product. Please read this instruction manual carefully before using the instrument. It will provide you with the necessary information for correct use of the instrument, as well as a precise idea of its versatility. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com or see the back cover for our worldwide contact list. [. . . ] The conductivity calibration menu includes 3 different types of calibration: Conductivity, Actual conductivity and Salinity. The "Conductivity" option allows a single point calibration with a standard solution selectable by the user. The "Actual conductivity" option allows a single point calibration with a custom conductivity solution of known actual value (not temperature compensated). The "Salinity" option allows calibration with a standard salinity solution. 35 The 3 options are correlated, so that each of the procedures will calibrate all the 3 ranges. Note For correct EC readings, calibration should be performed using a standard solution with a conductivity value close to the sample to be measured. After choosing the "Conductivity calibration" mode from the "Calibration" menu, select the calibration type with the arrow keys and then press <OK>. Conductivity · Select the "Conductivity" option and press <OK> to confirm. · Fill a beaker with a standard conductivity solution (see "Accessories" section for choosing the proper HANNA solution). · Immerse the probe in the solution and wait for stable reading. · The main display shows the actual reading, while the secondary level displays the standard value. Actual Conductivity · Select the "Actual conductivity" option and press <OK> to confirm. · Immerse the probe in the conductivity solution and wait for stable reading. · When the reading is stable, press <Confirm> to store the calibration data. · After confirmation, the following messages are displayed: "Storing data on probe, please wait. . . ", "Updating GLP data, please wait. . . " and "Calibration completed". · Press <OK> to return to the "Calibration" menu. Salinity · Select the "Salinity" option and press <OK>. · Insert the salinity value of the custom calibration solution. · Immerse the probe in the solution and wait for stable reading. · When the reading is stable, press <Confirm> to store the calibration data. · After confirmation, the following messages are displayed: "Storing data on probe, please wait. . . ", "Updating GLP data, please wait. . . " and "Calibration completed". · Press <OK> to return to the "Calibration" menu. To calibrate the offset, set the calibration point at 0 S/cm and repeat the procedure. If the temperature input is not within the acceptable range (0 to 50°C), the message "Invalid temperature" is displayed. If the conductivity input is not within the acceptable range, the message "Invalid input" is displayed. · To change the standard value, press <Cal. [. . . ] · If the bulb and/or junction are dry, soak the electrode in HI70300 storage solution for at least one hour. · To minimize clogging and ensure a quick response time, the glass bulb and the junction should be kept always moist and not allowed to dry. · Store the electrode with a few drops of HI70300 storage solution in the protective cap. NEVER USE DISTILLED OR DEIONIZED WATER TO STORE THE pH ELECTRODE. 58 59 · Inspect the electrode for scratches or cracks. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98280




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 98280 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.