User manual HANNA INSTRUMENTS HI 98230

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98230. We hope that this HANNA INSTRUMENTS HI 98230 user guide will be useful to you.


HANNA INSTRUMENTS HI 98230 : Download the complete user guide (1064 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 98230 (1060 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 98230

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 98230 - HI 98240 Portable Microprocessor Printing and Logging pH / ORP Meters http://www. hannainst. com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument, as well as a precise idea of its versatility in a wide range of applications. These instruments are in compliance with PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipping. [. . . ] The instrument then checks the electrode parameters and advises user of abnormalities by "old probe" and "dead probe" indications. Rinse the electrode with some of the second buffer solution or clean water. Dip the bottom, 4 cm (1½"), of the electrode in a beaker containing the second buffer. When the "S" symbol blinks in the lower LCD, press ALT and CFM to confirm the second calibration point. CALIBRATION DATA PRINTOUT It is possible to print the characteristics of the electrode as a recording of the electrode performance over time by setup code 12 (see "Printing GLP data"). This will consist of: date, time, the offset characteristic of the pH electrode in mV, the slope characteristic in mV/pH and the pH buffer solution values. If calibration has been performed with an "old" pH electrode the first line is: pH ** If calibration has been performed with a "dead" pH electrode the first line is: pH -If the calibration alarm time-out is expired, the "Dt" string will be printed beside the date. Note: A dashed line indicates that the calibration has never been performed. 18 19 mV CALIBRATION PROCEDURE (HI98240 ONLY) A four-point calibration must be performed. The first two calibration points are 0. 0 and +350. 0 mV for low range calibration; the other two calibration points are 0 and +350 or +1900 mV for high range calibration. Connect a mV simulator (HI8427 or HI931001 with the proper connecting cable) to the meter and set it to 0 mV. User is prompted to enter password if it has been set to a value different from 0000, otherwise skip to step 6. Press ALT and CFM to confirm the password or ALT and CAL to return to normal operational mode. If password is correct or not set, the meter will display "0. 0 mV" on the upper LCD and "b1" on the lower; if wrong, it will return to normal operational mode without any message. When the "S" symbol blinks in the lower LCD, the reading is stable and calibration can be confirmed. When the "S" symbol blinks in the lower LCD, the reading is stable. The meter will display "350 mV" in the upper LCD and "b4" on the lower one. Pressing the " " key, 1900 mV will be selected as calibration point. Note: +1900 mV is suggested as the last calibration point to obtain the best accuracy throughout the entire mV range. When the "S" symbol blinks in the lower LCD, the reading is stable. Calibration is now complete and the instrument returns to normal operational mode. Note: "Err" message notifies the user if the selected value is wrong. TEMPERATURE CALIBRATION PROCEDURE ( for technical personnel only) The meter is factory calibrated for temperature. It is recommended that the following procedure is performed by authorized technical personnel only. A two point calibration at 0. 0, 25. 0 C (32. 0, 77. 0 F) or 0. 0, 50. 0 C (32. 0, 122. 0 F) has to be performed in order to store the new calibration data in memory. [. . . ] Slow Response/Excessive Drift: Soak the tip in HI7061 or HI8061 Hanna Solution for 30 minutes, rinse thoroughly in distilled water and then follow the Cleaning Procedure above. ACCESSORIES pH CALIBRATION SOLUTIONS HI 70004P HI 70007P HI 70010P HI 7004L HI 7006L HI 7007L HI 7009L HI 7010L HI 8004L HI 8006L HI 8007L HI 8009L HI 8010L pH 4. 01 Buffer Sachets, 20mL, 25 pcs pH 7. 01 Buffer Sachets, 20mL, 25 pcs pH 10. 01 Buffer Sachets, 20mL, 25 pcs pH 4. 01 Buffer Solution, 460 mL bottle pH 6. 86 Buffer Solution, 460 mL bottle pH 7. 01 Buffer Solution, 460 mL bottle pH 9. 18 Buffer Solution, 460 mL bottle pH 10. 01 Buffer Sol. , 460 mL bottle pH 4. 01 Buffer Solution, 460 mL FDA approved bottle pH 6. 86 Buffer Solution, 460 mL FDA approved bottle pH 7. 01 Buffer Solution, 460 mL FDA approved bottle pH 9. 18 Buffer Solution, 460 mL FDA approved bottle pH 10. 01 Buffer Solution, 460 mL FDA approved bottle ELECTRODE STORAGE SOLUTION HI 70300L Storage Solution, 460 mL bottle HI 80300L Storage Solution, 460 mL FDA approved bottle ELECTRODE CLEANING SOLUTIONS HI 70000P HI 7061L HI 7073L HI 7074L HI 7077L HI 8061L HI 8073L HI 8077L HI 7072 HI 7082 HI 8072 HI 8082 Electrode Cleaning Sachets, 20 mL, 25 pcs General Cleaning Solution, 460 mL bottle Protein Cleaning Solution, 460mL bottle Inorganic Cleaning Solution, 460mL bottle Oil & Fat Cleaning Solution, 460 mL bottle General Cleaning Solution, 460 mL FDA approved bottle Protein Cleaning Solution, 230 mL FDA approved bottle Oil & Fat Cleaning Solution, 460mL FDA approved bottle 1M KNO3 Electrolyte, 4x50 mL 3. 5M KCl Electrolyte, 4x50 mL, for double junction electrodes 1M KNO3 Electrolyte, 4x50 mL FDA approved bottle 3. 5M KCl Electrolyte, 4x50 mL FDA approved bottle, for double junction electrodes Reducing Pretreatment Solution, 460 mL bottle Oxidizing Pretreatment Solution, 460 mL bottle REFILL ELECTROLYTE SOLUTIONS ORP PRETREATMENT SOLUTIONS HI 7091L HI 7092L 34 35 ELECTRODES HI1615D combination pH electrode, glass-body, single junction, refillable with built-in temperature NTC sensor and EEPROM for GLP data storing. combination pH electrode, glass-body, single junction, gel-filled with built-in temperature NTC sensor and EEPROM for GLP data storing. combination pH electrode, glass-body, single junction, triple ceramic, refillable with built-in temperature NTC sensor and EEPROM for GLP data storing. combination pH electrode, single junction, gel-filled with built-in temperature NTC sensor and EEPROM for GLP data storing. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98230




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 98230 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.