User manual HANNA INSTRUMENTS HI 981504

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 981504. We hope that this HANNA INSTRUMENTS HI 981504 user guide will be useful to you.


HANNA INSTRUMENTS HI 981504 : Download the complete user guide (481 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 981504

Detailed instructions for use are in the User's Guide.

[. . . ] ±0. 3°C / ±0. 5°F 0. 5 (HI 981504/5) or 0. 7 (HI 981504/7) Manual, 2 point, through trimmers Manual, 1 point, through trimmer Factory calibrated HI 1286 (included) HI 7634 (fixed) Stainless steel, 2 m cable (fixed) Automatic, 5 to 50°C (41 to 122°F), for TDS readings only 0 to 50 °C (32 to 122°F); RH max 95% 12 Vdc power adapter (included) 160 x 110 x 35 mm (6. 3x4. 3x1. 4'') 560 g (1. 2 lb. ) PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully. If any damage has occurred during shipment, immediately notify your Dealer or the nearest Hanna Customer Service Center. Each meter is supplied with: · HI 1286 pH electrode · HI 7634 TDS probe & temperature probe (fixed) · pH 4 & pH 7 buffer sachets, 1 pc. each · HI 70032 (1382 ppm) sachet for HI 981504/5 or HI 70442 (1500 ppm) sachet for HI 981504/7 · HI 700661 cleaning solution sachet, 2 pcs · Screwdriver, 12 Vdc power adapter & instructions Note: Conserve all packing material until the instrument has been observed to function correctly. [. . . ] Measurements are accurate and the meter can be calibrated at one or two points for pH, and at a single point for TDS. Two models are available: · HI 981504/5 with 0. 5 TDS factor · HI 981504/7 with 0. 7 TDS factor All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments. 1. 12. Backlit LCD for pH readings pH calibration trimmers Backlit LCD for TDS readings TDS calibration trimmer Backlit LCD for temperature readings BNC connector (pH electrode) Protective sheath for BNC connector HI 1286 pH electrode HI 7634 TDS probe (fixed) Temperature probe (fixed) 12 Vdc power adapter Power supply connector Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which it is used. Operation of these instruments in residential areas could cause unacceptable interferences to radio and TV equipment. The glass bulb at the end of the electrode is sensitive to electrostatic discharges. During operation, ESD wrist straps should be worn to avoid possible damage to the electrode by electrostatic discharges. Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance. To avoid electrical shock, do not use this instrument when voltage at the measurement surface exceeds 24 Vac or 60 Vdc. To avoid damage or burns, do not perform any measurement in microwave ovens. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. °C/°F SELECTION · The user can easily select the temperature unit, in degrees Celsius (default) or Fahrenheit through a switch on the rear panel. Replace the label for better protection against humidity. TDS CALIBRATION · Turn the meter on. · Pour a small quantity of the proper calibration solution (HI 7032 for HI 981504/5 or HI 70442 for HI 981504/7) in a beaker. · Immerse the TDS probe in the solution, making sure that the metal pins are completely submerged. Note: For best accuracy, the probe body should not touch nor stand close to the side walls of the beaker. · Wait for a couple of minutes for thermal equilibrium to be reached and the temperature to be compensated. · Tap the probe gently on the bottom and shake it, to make sure no air bubbles have remained trapped inside. · Adjust the calibration trimmer with the supplied screwdriver until the display shows "1380" ppm (HI 981504/5) or "1500" ppm (HI 981504/7) Calibration is now complete. pH ELECTRODE MAINTENANCE · When not in use, rinse the electrode with water and store it with a few drops of HI 70300 storage solution in the protective cap. · If the electrode has been left dry, soak the tip in HI 70300 storage solution overnight to reactivate it. · To minimize clogging and provide longer life for the pH electrode, it is recommended to clean it at least once a week. Immerse the tip of the electrode in the HI 700661 cleaning solution supplied with the instrument, for half an hour and then rinse it with tap water. ACCESSORIES HI 1286 HI 7634* HI 70004P HI 7004M HI 70007P HI 7007M HI 70010P HI 7010M HI 70032P HI 7032M HI 70442P HI 70442M HI 70300M HI 700661P HI 7061M HI 710005 HI 710006 HI 731326 Double junction, plastic body pH electrode with 2 m (6. 6') cable and BNC connector TDS probe with 2 m (6. 6') cable pH 4. 01 solution, 20 mL sachet (25 pcs) pH 4. 01 solution, 230 mL bottle pH 7. 01 solution, 20 mL sachet (25 pcs) pH 7. 01 solution, 230 mL bottle pH 10. 01 solution, 20 mL sachet (25 pcs) pH 10. 01 solution, 230 mL bottle 1382 ppm solution, 20 mL sachet (25 pcs) 1382 ppm solution, 230 mL bottle 1500 ppm solution, 20 mL sachet (25 pcs) 1500 ppm solution, 230 mL bottle Storage solution, 230 mL bottle Cleaning solution, 20 mL sachet (25 pcs) Cleaning solution, 230 mL bottle 115 Vac / 12 Vdc power adapter 230 Vac / 12 Vdc power adapter Calibration screwdriver (20 pcs) pH ELECTRODE CONNECTION In order to protect the instrument against vapors and humidity, the BNC connector is protected with a waterproof sheath. [. . . ] For best accuracy, the probes should not touch or stand close to the vessel's walls or bottom. · The three backlit LCDs will show the pH, TDS and temperature values, respectively. Any initial variation in readings may be due to the pH electrode conditioning and to the temperature compensation of TDS measurements. Allow the readings to stabilize. TDS PROBE MAINTENANCE It is recommended to clean the probe at least once a month, by following this procedure: · Immerse the tip of the probe in the HI 700661 cleaning solution supplied with the instrument, for half an hour. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 981504




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 981504 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.