User manual HANNA INSTRUMENTS HI 98121

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98121. We hope that this HANNA INSTRUMENTS HI 98121 user guide will be useful to you.


HANNA INSTRUMENTS HI 98121 : Download the complete user guide (405 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 98121 (521 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 98121

Detailed instructions for use are in the User's Guide.

[. . . ] To avoid damages or burns, do not perform any measurement in microwave ovens. www. hannainst. com This Instrument is in Compliance with CE Directives WARRANTY HI 98121 is warranted for one year against defects in workmanship and materials when used for its intended purpose and maintained according to instructions. Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. [. . . ] Submerge the electrode in the solution to be tested while stirring it gently. The measurements should be taken when the stability symbol on the top left of the LCD disappears. The pH value automatically compensated for temperature is shown on the primary LCD while the secondary LCD shows the temperature of the sample. Note: Before taking any pH measurement make sure the meter has been calibrated (CAL tag present on the LCD). pH Calibration For better accuracy, frequent calibration of the instrument is recommended. In addition, the instrument must be recalibrated whenever: a) The pH electrode is replaced. Calibration procedure From normal measuring mode, press and hold the /MODE button until OFF on the secondary LCD is replaced by CAL. The LCD enters the calibration mode displaying "pH 7. 01 USE" (or "pH 6. 86 USE" if the NIST buffer set was selected). After 1 second the meter activates the automatic buffer recognition feature. If a valid buffer is detected then its value is shown on the primary display and REC appears on the secondary LCD. If no valid buffer is detected, the meter keeps the USE indication active for 12 seconds, and then it replaces it with WRNG, indicating the sample being measured is not a valid buffer. · For a single-point calibration with buffers pH 4. 01, 9. 18 or 10. 01, the meter automatically accepts the calibration when the reading is stable; the meter displays the accepted buffer, with the message "OK 1". After 1 second the meter automatically returns to the normal measuring mode. If a single-point calibration with buffer pH 7. 01 (or pH 6. 86) is desired, then after the calibration point /MODE button must be has been accepted the pressed in order to return to normal mode. After the button is pressed, the meter shows "7. 01" (or "6. 86") - "OK 1" and, after 1 second, it automatically returns to the normal measuring mode. Note: It is always recommended to carry out a twopoint calibration for better accuracy. -2. 00 to 16. 00 pH ±1000 mV 0. 01 pH 1 mV 0. 1°C or 0. 1°F ±0. 05 pH ±2 mV ±0. 5°C or ±1°F ±0. 02 pH ±2 mV ±0. 3°C or ±0. 6°F Automatic for pH -5 to 50°C (23 to 122°F); RH 100% pH: at 1 or 2 points with 2 sets of memorized buffers (pH 4. 01/7. 01/ 10. 01 or pH 4. 01/6. 86/9. 18) ORP: factory calibrated buffer (pH 4. 01, pH 10. 01, or pH 9. 18) is detected, then the meter completes the calibration procedure. When the buffer is accepted, the LCD shows the accepted value with the "OK 2" message, and then the meter returns to the normal measuring mode. Note: When the calibration procedure is completed, the CAL tag is turned on. To quit calibration and to reset to the default values · After entering the calibration mode and before the first point is accepted, it is possible to quit the procedure and return to the last calibration data by pressing the /MODE button. The secondary LCD displays "ESC" for 1 second and the meter returns to the normal measuring mode. [. . . ] When the battery level is below 5%, the - + symbol on the bottom left of the LCD lights up to indicate a low battery condition. If the battery level is low enough to cause erroneous readings, the meter shows "0%" and the Battery Error Prevention System (BEPS) will automatically turn the meter off. To change the batteries, remove the 4 screws located on the top of the meter. SETUP Setup mode allows the selection of temperature unit and pH buffer set. To enter the Setup mode, select pH mode and then press the /MODE button until CAL on the secondary display is replaced by TEMP and the current temperature unit (E. g. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98121




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 98121 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.