User manual HANNA INSTRUMENTS HI 98120

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98120. We hope that this HANNA INSTRUMENTS HI 98120 user guide will be useful to you.


HANNA INSTRUMENTS HI 98120 : Download the complete user guide (396 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 98120 (525 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 98120

Detailed instructions for use are in the User's Guide.

[. . . ] direc- FUNCTIONAL DESCRIPTION CE DECLARATION OF CONFORMITY HI 98120 Waterproof ORP & Temperature Meter PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully. If any damage has occurred during shipment, immediately notify your Dealer or the nearest Hanna Customer Service Center. Each meter is supplied with: · HI 73120 ORP electrode · HI 73128 Electrode removal tool · 4 x 1. 5V batteries Note: Conserve all packing material until the instrument has been observed to function correctly. [. . . ] This meter is also provided with battery level indication at start-up, and with a low battery symbol which warns the user when the batteries need to be replaced. In addition the Battery Error Prevention System (BEPS) avoids erroneous reading caused by low voltage level by turning the meter off. The HI 73120 ORP electrode, supplied with the meter, is interchangeable and can be easily replaced by the user. The stainless steel encapsulated temperature sensor facilitates faster and more accurate temperature measurement. 1. 6. Battery compartment Liquid Crystal Display (LCD) ON/OFF/MODE button HI 73120 ORP electrode Temperature sensor SET/HOLD button Recommendations for Users Before using this product, make sure that it is entirely suitable for the environment in which it is used. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. To avoid electrical shock, do not use this instrument when voltages at the measurement surface exceed 24 VAC or 60 VDC. To avoid damages or burns, do not perform any measurement in microwave ovens. 1. 6. Stability indicator Battery life percentage indicator Low battery indicator Secondary display Primary display Measuring unit for primary display ISTR98120 03/03 SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) Typical EMC Deviation Environment Calibration Electrode Battery Type Life Auto-off Dimensions Weight ORP: ± 1000 mV Temp: -5. 0 to 60. 0°C/23. 0 to 140. 0°F ORP: 1 mV Temp: 0. 1°C / 0. 1°F ORP: ±2 mV Temp: ±0. 5°C / ±1°F ORP: ±2 mV Temp: ±0. 3°C / ±0. 6°F -5 to 50°C (23 to 122°F); RH 100% factory calibrated HI 73120 ORP electrode (included) 4 x 1. 5V with BEPS typical 300 hours After 8 minutes 163 x 40 x 26 mm (6. 4 x 1. 6 x 1. 0") 85 g (3. 0 oz) To turn the meter off While in normal measuring mode, press the / MODE button. Note: If measurements are taken in different samples successively, rinse the probe thoroughly to eliminate cross-contamination; and after cleaning, rinse the probe with some of the sample to be measured. Replace the top, making sure that the gasket is properly seated in place, and tighten the screws to ensure a watertight seal. HI 73120 HI 73128 HI 7021M HI 7022M HI 7061M HI 70300M HI 7091M ACCESSORIES Replaceable ORP electrode Electrode removal tool ORP test solution (240 mV), 230 mL bottle ORP test solution (470 mV), 230 mL bottle Electrode cleaning solution, 230 mL bottle Electrode storage solution, 230 mL bottle Pretreatment reducing solution, 230 mL bottle HI 7092M Pretreatment oxidizing solution, 230 mL bottle FACTORY RECALIBRATION The ORP range is factory calibrated. Contact your nearest Hanna Service Center for recalibration, if necessary. SETUP Setup mode allows the selection of temperature unit. To enter the Setup mode, °C/°F selection, press the /MODE button until TEMP and the current temperature unit are displayed on the lower part of the LCD (E. g. Use the SET/HOLD button to change the temperature unit, and then press the /MODE button to return to the normal measuring mode. ELECTRODE MAINTENANCE · When not in use, rinse the electrode with water to minimize contamination and store it with a few drops of HI 70300 storage solution in the protective cap after use. · If the electrode has been left dry, soak in storage solution for at least one hour to reactivate it. · To prolong the life of the electrode, it is recommended to clean it monthly by immersing it in the HI 7061 cleaning solution for half an hour. · The ORP electrode can be easily replaced by using the supplied tool (HI 73128). [. . . ] Press any button to return to normal mode. BATTERY REPLACEMENT The meter displays the remaining battery percentage every time it is switched on. When the battery level is below 5%, the - + symbol on the bottom left of the LCD lights up to indicate a low battery condition. If the battery level is low enough to cause erroneous readings, the meter shows "0%" and the Battery Error Prevention System (BEPS) will automatically turn the meter off. · HI 98130 Rotate the electrode counterclockwise. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98120




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 98120 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.