User manual HANNA INSTRUMENTS HI 9811-5

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 9811-5. We hope that this HANNA INSTRUMENTS HI 9811-5 user guide will be useful to you.


HANNA INSTRUMENTS HI 9811-5 : Download the complete user guide (466 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 9811-5 09-10 (440 ko)
   HANNA INSTRUMENTS HI 9811-5 MANUEL 2 (576 ko)
   HANNA INSTRUMENTS HI 9811-5 MANUEL 3 (466 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 9811-5

Detailed instructions for use are in the User's Guide.

[. . . ] To avoid damages or burns, do not perform any measurement in microwave ovens. WARRANTY HI 9811-5 is guaranteed for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. Damage due to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the problem. [. . . ] 13 ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2 Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. 15 ACCESSORIES PROBES HI 1285-0 PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipment. Each meter is supplied with: · HI 1285-5, pH/EC/TDS/°C combination probe with 8-pin DIN connector and 1 m (3. 3') cable · HI 70007, pH 7. 01 sachet, 1 pc · HI 70031, 1413 µS/cm sachet, 1 pc · HI 70032, 1382 ppm (mg/L) sachet, 1 pc · HI 700661 cleaning solution sachet, 2 pcs · Instruction manual · 1 x 9V alkaline battery · Rugged carrying case. Note: Save all packing material until you are sure that the instrument functions correctly. Any defective item must be returned in the original packing together with the supplied accessories. HI 1285-5 Combination, amplified pH/EC/TDS probe with built-in temperature sensor, 8-pin DIN connector and 1 m (3. 3') cable Combination, amplified pH/EC/TDS/temperature probe with built-in temperature sensor, 8-pin DIN connector and 1 m (3. 3') cable pH BUFFER SOLUTIONS HI 7004L pH 4. 01 buffer solution, 500 mL bottle HI 7006L pH 6. 86 buffer solution, 500 mL bottle HI 7007L pH 7. 01 buffer solution, 500 mL bottle HI 7009L pH 9. 18 buffer solution, 500 mL bottle HI 7010L pH 10. 01 buffer solution, 500 mL bottle CONDUCTIVITY & TDS CALIBRATION SOLUTIONS HI 7031L 1413 µS/cm solution, 500 mL bottle HI 7032L 1382 ppm (mg/L) solution, 500 mL bottle OTHER SOLUTIONS HI 700661P Cleaning Solution, 20 mL sachet (25 pcs) HI 70300L Storage Solution, 500 mL bottle HI 7073L Protein Cleaning Solution, 500 mL bottle HI 7074L Inorganic Cleaning Solution, 500 mL bottle HI 7077L Oil & Fat Cleaning Solution, 500 mL bottle OTHER ACCESSORIES HI 710007 Shockproof rubber boot, blue HI 710008 Shockproof rubber boot, orange HI 710050 Blue protective case GENERAL DESCRIPTION HI 9811-5 is the complete, versatile, with a large LCD and splashproof portable combination meter designed with the utmost precision and simplicity. The instrument provides measurements for pH, EC and TDS ranges, which are easily selectable through the keypad on the front panel. Conductivity measurements are automatically compensated for temperature changes with a built-in temperature sensor. HI 9811-5 is a pH/EC/TDS meter designed for simplicity of use in taking pH, µS/cm, mg/L and temperature measurements. Suited for hydroponics, greenhouses, farming and ground water applications. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner. 14 3 FUNCTIONAL DESCRIPTION PROBE MAINTENANCE PERIODIC MAINTENANCE Inspect the probe and the cable. The cable used for the connection to the meter must be intact and there must be no points of broken insulation on the cable or cracks on the probe stem or bulb. CLEANING PROCEDURE For better accuracy in measurements and to ensure a good performance of the probe, a frequent cleaning is recommended. For this purpose, soak it in Hanna HI 700661 Cleaning Solution for 5 minutes. Notes: · For particular dirty (as for example protein, oil or grease) see the "Accessories" section for Hanna specific solutions. · After cleaning the probe, it is recommended to recalibrate the meter. If it is not possible to calibrate, the probe has to be replaced with a new one. · For field applications, it is always recommended to keep a spare probe handy. When anomalies are not resolved with simple maintenance, change the probe and recalibrate the meter. 1) 2) 3) 4) 5) 6) 7) 8) 9) 8-pin DIN connector for probe Liquid Crystal Display pH range selection key µS/cm (EC) range selection key mg/L (TDS) selection key pH offset calibration knob EC/TDS calibration knob °C (Temperature) selection key On/Off key 4 13 BATTERY REPLACEMENT These meters are powered by a 9V battery that is located on the rear of the instrument. When battery symbol is empty a low battery condition is indicated. Range SPECIFICATIONS 0. 0 to 14. 0 pH 0 to 6000 µS/cm 0 to 3000 mg/L 0. 0 to 70. 0 °C 0. 1 pH 10 µS/cm 10 mg/L 0. 1 °C ±0. 1 pH ±2% f. s. mg/L ±0. 5 °C 0. 5 Manual, 1-point through offset trimmer Manual, 1-point through slope trimmer Automatic from 0 to 50 °C (32 to 122 °F) with =2%/°C HI 1285-5 1 x 9V alkaline Approx. 150 hours of continuouse use 0 to 50 °C (32 to 122 °F) 100% RH 145 x 80 x 36 mm (5. 7 x 3. 1 x 1. 4") 230 g (8. 1 oz. ) When the low battery indication appears, only a few hours of working time remains. When the battery level is so low that it may cause unreliable measurements, the meter turns off. [. . . ] 6 EC/TDS CALIBRATION Accessories needed: · Use HI 70031 (1413 µS/cm) EC calibration solution or HI 70032 (1382 ppm, or mg/L) TDS calibration solution. Note: The conversion between EC and TDS is made by a built-in circuit, hence it is requested to calibrate the meter only in EC or TDS range. PROCEDURE · Pour approximately 4 cm (1½") of a conductivity calibration solution (e. g. · Wait for a couple of minutes for thermal equilibrium to be reached. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 9811-5




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 9811-5 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.