User manual HANNA INSTRUMENTS HI 9811-0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 9811-0. We hope that this HANNA INSTRUMENTS HI 9811-0 user guide will be useful to you.


HANNA INSTRUMENTS HI 9811-0 : Download the complete user guide (576 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 9811-0

Detailed instructions for use are in the User's Guide.

[. . . ] If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization number from the Customer Service department and then send it with shipping costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. TABLE OF CONTENTS PRELIMINARY EXAMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 150 hours of continuous use Environment 0 to 50°C (32 to 122°F); 100% RH Dimensions 165 x 75 x 45 mm (6. 5 x 3. 0 x 1. 8") Weight 180 g (6. 3 oz. ) 1) 2) 3) 4) 5) 6) 7) 8) 9) 8-pin DIN connector for probe Liquid Crystal Display pH range selection key µS/cm (EC) range selection key EC/TDS calibration knob pH offset calibration knob mg/L (TDS) selection key °C (Temperature) selection key, for HI 9811-5 only ON/OFF key 4 5 OPERATIONAL GUIDE INITIAL PREPARATION Each meter is supplied complete with a 9V battery. Remove the battery compartment cover on the back of the meter and install the battery while paying attention to its polarity. Connect the probe to the DIN socket on the top of the meter by aligning the pins with the socket and pushing in the plug. Always remove the electrode protective cap before taking any measurements and make sure the meter has been calibrated before taking any measurements. Turn the meter on by pressing the ON/OFF key. · Select the appropriate measurement range (EC or TDS). · Wait a couple of minutes for the temperature sensor to reach thermal equilibrium. The display will then show the measurement automatically temperature compensated for temperature with the appropriate indication among the following: "µS" symbol indicates the meter is in EC mode; no symbol indicates the meter is in TDS mode. TAKING pH MEASUREMENTS If the probe has been left dry, soak the tip in HI 70300 storage solution for a few minutes to reactivate it. · To take a pH measurement simply submerge the tip (4cm/1½") of the probe into the sample to be tested. · Stir briefly and wait a couple of minutes for the reading to adjust and stabilize. · If measurements are taken in different samples successively, it is recommended to rinse (clean) the probe thoroughly to eliminate cross-contamination. After cleaning, it is recommended to rinse the probe with some of the next sample to be measured. TAKING TEMPERATURE MEASUREMENTS (for HI 9811-5 only) · Submerge the tip (4cm/1½") of the probe into the sample to be tested. · Stir briefly and wait a couple of minutes for the reading to adjust and stabilize. The display shows the temperature value. TAKING EC/TDS MEASUREMENTS · Immerse the tip of the probe (4cm/1½") into the sample to be tested. If possible, use plastic beakers or containers to minimize any EMC interference. · Tap the probe lightly on the bottom of the beaker to remove any air bubbles which may be trapped inside the tip. 6 Note: If the display shows only a "1" on the far left hand side, the reading is out of range. Note: It is recommended to clean often the probe with HI 700661 Cleaning Solution. Note: After measurements have been completed, the instrument should be switched off, and the probe cleaned and covered with the protective cap. 7 pH CALIBRATION For greatest accuracy, frequent calibration of the instrument is recommended. The instrument should be recalibrated for pH: a) Whenever the electrode is replaced. d) Where extreme accuracy is required. Note: The probe should be submerged approximately 4 cm (1½") into the solution. Note: If turning the knob the needed value can not be reached, clean the probe (see the "Probe Maintenance" section). If also after the probe cleaning the value can not be reached, replace the probe. PREPARATION Pour small quantities of pH 7. 01 (HI 7007) or pH 4. 01 (HI 7004) or pH 10. 01 (HI 7010) solution into a clean beaker. To obtain accurate readings, use pH 7. 01 (HI 7007) if you are going to measure neutral or close to neutral samples, pH 4. 01 (HI 7004) if you are going to measure acidic samples or pH 10. 01 (HI 7010) for alkaline measurements. If you need to calibrate to NBS standards, use pH 6. 86 (HI 7006) instead of pH 7. 01 and pH 9. 18 (HI 7009) instead of pH 10. 01. pH VALUES AT VARIOUS TEMPERATURES For temperature compensation during calibration, please refer to the following chart. [. . . ] Operation of these instruments in residential areas could cause unacceptable interferences to radio and TV equipment. The glass bulb at the end of the electrode is sensitive to electrostatic discharges. During operation, ESD wrist straps should be worn to avoid possible damage to the electrode by electrostatic discharges. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 9811-0




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 9811-0 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.