User manual HANNA INSTRUMENTS HI 96804

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 96804. We hope that this HANNA INSTRUMENTS HI 96804 user guide will be useful to you.


HANNA INSTRUMENTS HI 96804 : Download the complete user guide (310 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 96804

Detailed instructions for use are in the User's Guide.

[. . . ] Key features include: · Dual-level LCD · Automatic Temperature Compensation (ATC) · Easy setup and storage · Battery operation with Low Power indicator (BEPS) · Automatically turns off after 3 minutes of non-use. TABLE OF CONTENTS PRELIMINARY EXAMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 PRINCIPLE OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] A result of this property is that light will "bend", or change direction, when it travels through a substance of different refractive index. When passing from a material with a higher to lower refractive index, there is a critical angle at which an incoming beam of light can no longer refract, but will instead be reflected off the interface. The critical angle can be used to easily calculate the refractive index according to the equation: FUNCTIONAL DESCRIPTION TOP VIEW sin (critical) = n2 / n1 Where n2 is the refractive index of the lower-density medium; n1 is the refractive index of the higher-density medium. In the HI 96804, light from an LED passes through a prism in contact with the sample. An image sensor determines the critical angle at which the light is no longer refracted through the sample. The HI 96804 automatically applies temperature compensation to the measurement and converts the refractive index of the sample to Invert Sugar concentration in units of percent (by weight). 1. Battery Compartment 4 5 DISPLAY ELEMENTS ERROR MESSAGES Error Code Err Descript ion Genera l fa ilure. Sa mp le is rea d ing lower tha n the 0 % BRIX sta nd a rd used for meter ca lib ra tion. Temp era ture exceed s ATC low limit (10 °C) d uring ca lib ra tion. Temp era ture exceed s ATC hig h limit (40 °C) d uring ca lib ra tion. LO Top d isp la y HI Top d isp la y LO Top d isp la y Cal seg ment ON 1. 8. SETUP: Factory Calibration Tag Measurement in Progress Tag Battery (blinks when low battery condition detected) Calibration Tag Automatic Temperature Compensation (blinks when temperature exceeds 10-40°C / 50-104°F range) Primary Display (displays measurement and error messages) Temperature Units Secondary Display (displays temperature measurements; when blinking, temperature has exceeded operation range: 0-80°C / 32-176°F) HI Top d isp la y Cal seg ment ON t LO Top d isp la y Cal seg ment ON t HI Top d isp la y Cal seg ment ON Air Prism surfa ce insufficiently covered . Conta ct Ha nna . MEASUREMENT GUIDELINES · · · · Handle instrument carefully. Do not spray water to any part of instrument except the "sample well" located over the prism. This includes most organic solvents and extremely hot or cold solutions. Absorb sample on soft tissue and rinse sample well with deionized or distilled water between samples. Do not use metallic tools such as needles, spoons or tweezers as these will scratch the prism. Elt nLt Ba ttery seg ment b linking <5% of b a ttery life is rema ining . · · Temp era ture va lues a re b linking 0. 0° or 80. 0°C Temp era ture mea surement out of sa mp ling ra ng e (0. 0 to 80. 0°C). Conta ct Ha nna . ATC seg ment b linking SETUP seg ment b linking 6 7 CALIBRATION Calibration should be performed daily, before measurements are made, when the battery has been replaced, or between a long series of measurements. Two instrument test screens will be displayed briefly; a LCD segment followed by the percentage of remaining battery life. When LCD displays dashes, the instrument is ready. MEASUREMENT Verify the instrument has been calibrated before taking measurements. Wipe off prism surface located at the bottom of the sample well. 2. Using plastic pipettes, fill the sample well with distilled or deionized water. [. . . ] The temperature unit will change from °C to °F or vice versa. °C or °F · Extract the battery from its location. · Replace with fresh 9V battery making certain to observe polarity. · Insert the back battery cover and fasten it by turning clockwise to engage. WARRANTY HI 96804 is warranted for two years against defects in workmanship and materials when used for its intended purpose and maintained according to the instructions. Damage due to accident, misuse, tampering or lack of prescribed maintenance is not covered. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 96804




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 96804 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.