User manual HANNA INSTRUMENTS HI 96769C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 96769C. We hope that this HANNA INSTRUMENTS HI 96769C user guide will be useful to you.


HANNA INSTRUMENTS HI 96769C : Download the complete user guide (835 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 96769C MANUAL 2 (1342 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 96769C

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 96769C Anionic Surfactants ISM www. hannainst. com This Instrument is in Compliance with the CE Directives 1 2 Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information for the correct use of the instrument. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. This instrument is in compliance with directives. TABLE OF CONTENTS PRELIMINARY EXAMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · All the reaction times reported in this manual are referred to 20°C (68°F). As a general rule of thumb, they should be doubled at 10°C (50°F) and halved at 30°C (86°F). · In order to maximize accuracy, prior to a measurement follow the validation procedure to be sure that the instrument is properly calibrated. If necessary, calibrate the instrument. STARTUP Prepare the instrument for measurement as follows: · Unpack the instrument by removing the dust protection sleeve from the instrument cuvet holder. · Place the battery in the instrument as described in the "BATTERY REPLACEMENT" chapter. 13 MEASUREMENT PROCEDURE · Turn the meter on by pressing ON/OFF. · When the beeper sounds briefly and the LCD displays dashes, the meter is ready. The blinking "ZERO" indicates that the instrument needs to be zeroed first. For most accurate results, use of a class A laboratory pipette is strongly recommended. Alternatively, it is possible to use the plastic pipette, to fill the glass vial up to the 25 mL mark. · Add 2 drops of HI 95769A-0 Anionic Surfactants Reagent A and 2 drops of HI 95769B-0 Anionic Surfactants Reagent B. The solution will turn blue. · Add exactly 10 mL of Chloroform reagent. For most accurate results, use a class A glass laboratory pipette is strongly recommended. Alternatively, it is possible to use another clean plastic pipette to fill the vial up to the 10 mL mark. 14 Notes: Chloroform is heavier than water thus it will sink to the bottom of the graduated glass vial; Do not mix up the pipettes. · Close tightly the glass vial with its cap and shake it vigorously for 30 seconds. · Press and hold READ/ /TIMER for three seconds and the display will show the countdown. Alternatively, wait for 2 minutes leaving the vial capped and undisturbed During this period, the chloroform layer separates from the aqueous layer: the color of the aqueous layer will fade slightly if anionic surfactants are present, while the chloroform layer will turn blue. · Using the long plastic pipette, remove the upper aqueous layer and discard. · Add to the vial about 15 mL of deionized water, up to the 25 mL mark. · Add 2 drops of HI 95769A-0 Anionic Surfactants Reagent A. 15 · Close tightly the glass vial with its cap and shake it vigorously for 30 seconds. · Press and hold READ/ /TIMER for three seconds and the display will show the countdown. Alternatively, wait for 2 minutes leaving the vial capped and undisturbed During this period, the chloroform layer separates from the aqueous layer. [. . . ] · Press ZERO/CFM to restore the factory calibration or press GLP/ again to abort factory calibration restore. · The instrument briefly notifies "done" when restores factory calibration and returns to measurement mode. 23 BATTERY MANAGEMENT To save battery, the instrument shuts down after 10 minutes of non-use in measurement mode and after 1 hour of non-use in calibration mode. If a valid measurement was displayed before auto shut off, the value is displayed when the instrument is switched on. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 96769C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 96769C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.