User manual HANNA INSTRUMENTS HI 96748

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 96748. We hope that this HANNA INSTRUMENTS HI 96748 user guide will be useful to you.


HANNA INSTRUMENTS HI 96748 : Download the complete user guide (655 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 96748

Detailed instructions for use are in the User's Guide.

[. . . ] Battery low: The battery must be replaced soon. Preliminary examination: Please examine this product carefully. Each HI 96748 Ion Selective Meter is supplied complete with: · Two Sample Cuvettes and Caps · 9V Battery · Instruction Manual Note: Save all packing material until you are sure that the instrument works correctly. For more details about spare parts and accessories see "Accessories". Dead battery: This indicates that the battery is dead and must be replaced. Once this indication is displayed, normal operation of the instrument will be interrupted. [. . . ] 7· Place the cuvette with the reacted deionized water (blank) into the holder and ensure that the notch on the cap is positioned securely into the groove. 8· Press READ/ /TIMER and the display will show the countdown prior to zeroing the blank. Alternatively wait for 30 seconds and then press ZERO/CFM and the lamp, cuvette and detector icons will appear on the display, depending on the measurement phase. 9· Insert the second cuvette with the reacted sample into the holder and ensure that the notch on the cap is positioned securely into the groove. In all cases the lamp, cuvette and detector icons will appear on the display, depending on the measurement phase. 10·At the end of measurement, the instrument 10 directly displays concentration in µg/L of manganese on the LCD. In this case, before zeroing and taking readings, add 2-3 drops of Dispersing agent (HI 93703-51) to each cuvette and swirl until complete dissolution of turbidity. INTERFERENCES: Interference may be caused by: Aluminum above 20 mg/L Cadmium above 10 mg/L Calcium above 200 mg/L as CaCO3 Cobalt above 20 mg/L Copper above 50 mg/L Iron above 10 mg/L Lead above 0. 5 mg/L Magnesium above 100 mg/L as CaCO3 Nickel above 40 mg/L Zinc above 15 mg/L. 9· At the end of the measurement the display will show the validation standard value. The reading should be within specifications as reported on the CAL CHECKTM Standard Certificate. If the value is found out of specifications, please check that the cuvettes are free of fingerprints, oil or dirt and repeat validation. If results are still found out of specifications then recalibrate the instrument. 9 11·Then the date of last calibration (e. g. : "01. 08. 2009") appears on the display, or "01. 01. 2009" if the factory calibration was selected before. If the key is kept pressed, the year number is automatically increased. 13·When the correct year has been set, press ZERO/CFM or READ/ /TIMER to confirm. If the key is kept pressed, the month number is automatically increased. 15·When the correct month has been set, press ZERO/CFM or READ/ /TIMER to confirm. Now the display will show the day blinking. 11-13 FACTORY CALIBRATION RESTORE It is possible to delete the calibration and restore factory calibration. 2 Factory Calibration Restore Accessories: REAGENT SETS HI 93748-01 Reagents for 50 tests HI 93748-03 Reagents for 150 tests OTHER ACCESSORIES HI 96748-11 CAL CHECKTM Standard Cuvettes (1 set) HI 721310 9V battery (10 pcs) HI 731318 Cloth for wiping cuvettes (4 pcs) HI 731331 Glass cuvettes (4 pcs) HI 731335 Caps for cuvettes (4 pcs) HI 93703-50 Cuvette cleaning solution (230 mL). CALIBRATION Note: It is possible to interrupt the calibration procedure at any time by pressing CAL CHECK or ON/OFF keys. 2· When the beeper sounds briefly and the LCD displays dashes, the meter is ready. 3· Press and hold CAL CHECK for three seconds to enter calibration mode. 4· Place the CAL CHECKTM Standard HI 96748-11 Cuvette A into the cuvette holder and ensure that the notch on the cap is positioned securely into the groove. 4 3 or 2· Press READ/ /TIMER to enter in the factory calibration restore screen. 3-4 3· Press ZERO/CFM to restore the factory 3-4 calibration or press GLP/ again to abort factory calibration restore. Warranty HI 96748 is warranted for two years against defects in workmanship and materials when used for its intended purpose and maintained according to the instructions. Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered. [. . . ] · Turn the instrument upside down and remove the battery cover by turning it counterclockwise. Validation and Calibration procedures Warning: do not validate or calibrate the instrument with standard solutions other than the Hanna CAL CHECKTM Standards, otherwise erroneous results will be obtained. For accurate validation and calibration results, please perform tests at room temperature (18 to 25°C; 64. 5 to 77. 0°F). Use the Hanna CAL CHECKTM cuvettes (see "Accessories") to validate or calibrate instruments. 16·Press GLP/ to edit the desired day (01-31). If the key is kept pressed, the day number is automatically increased. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 96748




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 96748 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.