User manual HANNA INSTRUMENTS HI 96742

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 96742. We hope that this HANNA INSTRUMENTS HI 96742 user guide will be useful to you.


HANNA INSTRUMENTS HI 96742 : Download the complete user guide (747 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 96742

Detailed instructions for use are in the User's Guide.

[. . . ] READ/ /TIMER key: In measurement mode, press to make a measurement, or press and hold for three seconds to start a pre-programmed countdown prior to measurement. Cuvette holder ON SAMPLE READING: Inverted cuvettes: The sample and the zero cuvette are inverted. Follow the instructions of the measurement procedure for zeroing the meter. Under range: A blinking "0. 00" indicates that the sample absorbs less light than the zero reference. [. . . ] Add the content of one packet of HI 93748A-0 Ascorbic acid, replace the cap and shake gently until completely dissolved. Add 0. 2 mL of the HI 93748B-0 Alkaline-cyanide reagent solution, replace the cap and invert gently to mix for about 30 seconds. Add 1 mL of the HI 93748C-0 0. 1% PAN indicator solution, replace the cap and shake gently. 9· Replace the cuvette into the holder and ensure that the notch on the cap is positioned securely into the groove. Alternatively, wait for: Iron LR: 30 seconds Manganese LR: 2 minutes Then press READ/ /TIMER. In all cases the lamp, cuvette and detector icons will appear on the display, depending on the measurement phase. 11·The instrument directly displays the concentration in mg/L of iron or in µg/L of manganese on the LCD, depending on the 11 selected parameter. In this case, before zeroing and taking readings, add 2-3 drops of Dispersing agent (HI 93703-51) to each cuvette and swirl until complete dissolution of turbidity. INTERFERENCES: · Iron LR: Cadmium above 4. 0 mg/L, Chromium6+ above 1. 2 mg/L, Copper above 0. 6 mg/L, Manganese above 50. 0 mg/L, Molybdenum above 4. 0 mg/L, Nitrite ion above 0. 8 mg/L, Chromium3+ above 0. 25 mg/L, Cobalt above 0. 05 mg/L, Cyanide above 2. 8 mg/L, Mercury above 0. 4 mg/L, Nickel above 1. 0 mg/L. Sample pH should be between 3 and 4 to avoid developed color to fade or turbidity formation. · Manganese LR: Aluminum above 20mg/L, Cadmium above 10mg/L, Calcium above 200 mg/L as CaCO3, Cobalt above 20 mg/L, Copper above 50 mg/L, Iron above 10 mg/L, Lead above 0. 5 mg/L, Magnesium above 100 mg/L as CaCO3, Nickel above 40 mg/L, Zinc above 15 mg/L. 8· Press CAL CHECK key and the lamp, cuvette and detector icons together with "CAL CHECK" will appear on the display, depending on the measurement phase. 9· At the end of the measurement the display will show the validation standard value. The reading should be within specifications as reported on the CAL CHECKTM Standard Certificate. If the value is found out of specifications, please check that the cuvettes are free of fingerprints, oil or dirt and repeat validation. If results are still found out of specifications then recalibrate the instrument. 8 9 CALIBRATION Validation and Calibration procedures Warning: do not validate or calibrate the instrument with standard solutions other than the Hanna CAL CHECKTM Standards, otherwise erroneous results will be obtained. For accurate validation and calibration results, please perform tests at room temperature (18 to 25°C; 64. 5 to 77. 0°F). Use the Hanna CAL CHECKTM cuvettes (see "Accessories") to validate or calibrate instruments. VALIDATION Validation Note: The validation is performed only for the selected parameter. For full validation of the instrument, the following procedure must be performed for each parameter. 2· When the beeper sounds briefly and the LCD displays dashes, the meter is ready. 3· Place the CAL CHECKTM Standard Cuvette A into the cuvette holder and ensure that the notch on the cap is positioned securely into the 4-5 groove. 4· Press ZERO/CFM and the lamp, cuvette and detector icons will appear on the display, depending on the measurement phase. 5· After a few seconds the display will show "-0. 0-". [. . . ] Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. To avoid damages or burns, do not put the instrument in microwave oven. For yours and the instrument safety do not use or store the instrument in hazardous environments. GLP In GLP mode, the last calibration date can be verified and the factory calibration can be restored. Last Calibration Date LAST CALIBRATION DATE 1· Press and hold RANGE/GLP/ for three seconds to enter GLP mode. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 96742




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 96742 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.