User manual HANNA INSTRUMENTS HI 96720C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 96720C. We hope that this HANNA INSTRUMENTS HI 96720C user guide will be useful to you.


HANNA INSTRUMENTS HI 96720C : Download the complete user guide (1203 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 96720C

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 96720C Calcium Hardness ISM www. hannainst. com 1 Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information for the correct use of the instrument. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. PRELIMINARY EXAMINATION Please examine this product carefully. Each HI 96720 Ion Selective Meter is supplied complete with: · Two Sample Cuvettes and Caps · Two CAL CHECK standard cuvettes HI 96720KIT · 9V Battery · 1 mL syringe with tip · Tissue for wiping cuvettes · Instrument quality certificate · Instruction Manual · Rigid carrying case TABLE OF CONTENTS PRELIMINARY EXAMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Check the procedure and make sure you use the same cuvette for reference (zero) and measurement. Battery low: The battery must be replaced soon. Over Range: A flashing value of the maximum concentration indicates an over range condition. The concentration of the sample is beyond the programmed range: dilute the sample and re-run the test. Dead battery: This indicates that the battery is dead and must be replaced. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the cuvette. · Do not let the reacted sample stand too long after reagent is added, or accuracy will be lost. · It is possible to take multiple readings in a row, but it is recommended to take a new zero reading for each sample and to use the same cuvette for zeroing and measurement. · After the reading it is important to discard immediately the sample, otherwise the glass might become permanently stained. · All the reaction times reported in this manual are referred to 20°C (68°F). As a general rule of thumb, they should be doubled at 10°C (50°F) and halved at 30°C (86°F). · In order to maximize accuracy, prior to a measurement follow the validation procedure to be sure that the instrument is properly calibrated. If necessary, calibrate the instrument. · When the beeper sounds briefly and the LCD displays dashes, the meter is ready. The blinking "ZERO" indicates that the instrument needs to be zeroed first. · Add 0. 5 mL of HI 93720A-0 Calcium indicator solution, then swirl to mix. · In the same beaker add 0. 5 mL of HI 93720B-0 Alkali solution for Calcium, then swirl to mix. · Fill two cuvettes with 10 mL of sample each. STARTUP Prepare the instrument for measurement as follows: · Unpack the instrument by removing the dust protection sleeve from the instrument cuvette holder. · Place the battery in the instrument as described in the "BATTERY REPLACEMENT" chapter. · Add 1 drop of HI 93720C-0 EGTA solution to one cuvette, replace the cap and swirl the solution. This is the blank. · Place the blank into the cuvette holder and ensure that the notch on the cap is positioned securely into the groove. MEASUREMENT PROCEDURE To compensate the meter for the sample turbidity or color, the measurement takes place in two phases. · Press ZERO/CFM and the lamp, cuvette and detector icons will appear on the display, depending on the measurement phase. 12 13 · After a few seconds, the display will show "-0. 0-". · Remove the blank and insert the second cuvette into the instrument and ensure that the notch on the cap is positioned securely into the groove. · Press READ/ the lamp, cuvette and detector icons will appear on the display, depending on the measurement phase. · At the end of measurement, the instrument directly displays concentration in mg/L (ppm) of calcium hardness, as CaCO3, on the LCD. To convert the result to mg/L Ca, multiply the reading by 0. 4. Now, follow normal measurement procedure. The true value of the sample is the reading obtained multiplied by a factor of one hundred (the dilution factor). [. . . ] · The instrument briefly notifies "done" when restores factory calibration and returns to measurement mode. BATTERY MANAGEMENT To save battery, the instrument shuts down after 10 minutes of non-use in measurement mode and after 1 hour of non-use in calibration mode. If a valid measurement was displayed before auto-shut off, the value is displayed when the instrument is switched on. The blinking "ZERO" means that a new zero has to be performed. One fresh battery lasts for around 750 measurements, depending on the light level. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 96720C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 96720C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.