User manual HANNA INSTRUMENTS HI 96711C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 96711C. We hope that this HANNA INSTRUMENTS HI 96711C user guide will be useful to you.


HANNA INSTRUMENTS HI 96711C : Download the complete user guide (1339 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 96711C

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 96711C Free and Total Chlorine ISM www. hannainst. com 1 Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information for the correct use of the instrument. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. TABLE OF CONTENTS PRELIMINARY EXAMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Please check the preparation of the zero cuvette. No Light: The instrument cannot adjust the light level. Please check that the sample does not contain any debris. b) on sample reading Inverted cuvettes: The sample and the zero cuvette are inverted. Zero: A zero reading was not taken. · Shaking the cuvette can generate bubbles in the sample, causing higher readings. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the cuvette. · Do not let the reacted sample stand too long after reagent is added, or accuracy will be lost. · It is possible to take multiple readings in a row, but it is recommended to take a new zero reading for each sample and to use the same cuvette for zeroing and measurement. · After the reading it is important to discard immediately the sample, otherwise the glass might become permanently stained. · All the reaction times reported in this manual are referred to 20°C (68°F). As a general rule of thumb, they should be doubled at 10°C (50°F) and halved at 30°C (86°F). · In order to maximize accuracy, prior to a measurement follow the validation procedure to be sure that the instrument is properly calibrated. If necessary, calibrate the instrument. STARTUP Prepare the instrument for measurement as follows: · Unpack the instrument by removing the dust protection sleeve from the instrument cuvette holder. · Place the battery in the instrument as described in the "BATTERY REPLACEMENT" chapter. · Do not place the instrument under direct sun light. RANGE SELECTION The HI 96711 can measure Free chlorine when range P1 is selected or Total chlorine when range P2 is selected. To change the active range follow the procedure: · Turn the meter on by pressing ON/OFF. · After startup, the range identification number is displayed on the secondary LCD as P1 or P2. Code P1 P2 Parameter Free Chlorine Total Chlorine · Press RANGE/GLP/ to change the range. The range can be changed any time when the instrument is in measurement mode. The selected range is memorized and the selection remaines unchanged at power off or when the battery is removed. 14 15 MEASUREMENT PROCEDURE To compensate the meter for the sample turbidity or color, the measurement takes place in two phases. Important note: Free and Total Chlorine have to be measured separately with fresh unreacted samples if both values are requested. The display briefly shows all tags on. · After a few seconds, the display will show "-0. 0-". · Add the content of one packet of the specific test reagent, for: Free Chlorine: 1 packet of HI 93701-0 or Total Chlorine: 1 packet of HI 93711-0 · When the beeper sounds briefly and the LCD displays dashes, the meter is ready. The blinking "ZERO" indicates that the instrument needs to be zeroed first. · Replace the cap and shake gently for 20 seconds (or 2 minutes in case of seawater analysis). · Pay attention to the selected range. To change the range, simply press RANGE/GLP/ . · Replace the cuvette into the cuvette holder and ensure that the notch on the cap is positioned securely into the groove. · Fill the cuvette with 10 mL of unreacted sample, up to the mark, and replace the cap. · Place the cuvette into the cuvette holder and ensure that the notch on the cap is positioned securely into the groove. · Press and hold READ/ /TIMER for three seconds. [. . . ] · The instrument briefly indicates "donE" upon restoration of factory calibration prior to returning to measurement mode. 23 or BATTERY MANAGEMENT To save battery, the instrument shuts down after 10 minutes of non-use in measurement mode and after 1 hour of non-use in calibration mode. If a valid measurement was displayed before auto shut off, the value is displayed when the instrument is switched on. The blinking "ZERO" means that a new zero has to be performed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 96711C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 96711C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.