User manual HANNA INSTRUMENTS HI 93734

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 93734. We hope that this HANNA INSTRUMENTS HI 93734 user guide will be useful to you.


HANNA INSTRUMENTS HI 93734 : Download the complete user guide (422 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 93734

Detailed instructions for use are in the User's Guide.

[. . . ] This instrument is in compliance with Specifications Display Code Guide This indicates that the meter is in a ready state and zeroing can be performed. This indicates that the meter is in a zeroed state and measurement can be performed. A blinking "0. 00" indicates that the sample absorbs less light than the zero reference. Check the procedure and make sure you use the same cuvet for reference (zero) and measurement. [. . . ] To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc. , Woonsocket, Rhode Island, 02895, USA. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. General Description The HI 93734 meter measures the Free and Total Chlorine (Cl2) content in water and wastewater. The meter uses an exclusive positive-locking system to ensure that the cuvet is in the same position every time it is placed into the measurement cell. The reagents are in powder and liquid form and are supplied in bottles and powder packets. The amount of reagent is precisely dosed to ensure maximum repeatability. The meters have an auto-shut off feature that will turn the instrument off after 10 minutes of non-use. Light Emitting Diode @ 555 nm Adaptation of the EPA recommended DPD method 330. 5. The reaction between the chlorine and the DPD reagent causes a pink tint in the sample Light Detector Silicon Photocell Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing Battery Type/Life 1 x 9 volt/40 hours Auto-Shut off After 10' of non-use Dimensions 180 x 83 x 46 mm (7. 1 x 3. 3 x 1. 8") Weight 290 g (10 oz. ). REQUIRED REAGENTS Code Description HI 93701-0 Free Chlorine Reagent HI 93734B-0 Free & Total Chlorine Reagent B HI 93734C-0 Total Chlorine Reagent C (for Total Chlorine only) Quantity 1 packet 5 mL 3 drops The "V" indicates that the battery voltage is getting low and the battery needs to be replaced. Change the battery to restart. REAGENT SETS HI 93734-01 Reagents for 100 Free & Total Chlorine tests HI 93734-03 Reagents for 300 Free & Total Chlorine tests Operational Guide MEASUREMENT PROCEDURE · Turn the meter on by pressing ON/OFF. ON OFF Note: rinse the 3 mL plastic pipette 2 or 3 times with sample before adding it to the cuvet with reagent. · Replace the cap and shake gently. · The instrument directly displays concentration in mg/L (ppm) of Free or Total Chlorine on the Liquid Crystal Display. Note: Free and Total Chlorine have to be measured separately with fresh unreacted samples following the above procedure if both values are requested. · When the LCD displays "- - -", it is ready. · Select Free or Total FREE Chlorine by pressing TOTAL FREE/TOTAL. An "I" or a "C" will appear on the right corner to indicate Free or Total Chlorine, respectively. · Place the cuvet into the holder and ensure that the notch on the cap is positioned securely into the groove. · Press ZERO and "SIP" will blink on the display. ZERO INTERFERENCES Interference may be caused by: Bromine, Iodine, Fluorine, Ozone, Oxidized Manganese and Chromium. Alkalinity above 250 mg/L or acidity above 150 mg/L will not reliably develop the full amount of color or it may rapidly fade. In case of water with hardness greater than 1000 mg/L CaCO3, shake the sample for approximately 1 minute after adding the powder reagent. recommended that a zero reading be taken for each sample and that the same cuvet is used for zeroing and measurement. · It is important to discard the sample immediately after the reading is taken because the glass might become permanently stained. · Shaking the cuvet can generate bubbles in the sample, causing higher readings. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the vial. · All the reaction times reported in this manual are referred to 20°C (68°F). [. . . ] Wipe it thoroughly with HI 731318 or a lint-free cloth prior to insertion. · It is possible to take multiple readings in a row, but it is HI 710009 HI 710010 HI 721310 HI 731318 HI 731321 HI 731325 HI 93703-50 C 215-00300 Blue rubber boot Orange rubber boot 9V battery (10 pcs) Tissue for wiping cuvets (4 pcs) Glass cuvets (4 pcs) Caps for cuvets (4 pcs) Cuvets cleaning solution (230 mL) 5 mL graduated syringe CE Declaration of Conformity Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences. Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 93734




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 93734 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.