User manual HANNA INSTRUMENTS HI 933000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 933000. We hope that this HANNA INSTRUMENTS HI 933000 user guide will be useful to you.


HANNA INSTRUMENTS HI 933000 : Download the complete user guide (234 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 933000 (553 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 933000

Detailed instructions for use are in the User's Guide.

[. . . ] Untitled-19 1 2 Instruction Manual HI 8033 - HI 8633 HI 8733 - HI 8734 HI 933000 Portable Multi-Range Conductivity/TDS Meters mS Dear Customer, Thank you for choosing a Hanna Product. Please read this instruction manual carefully before using the instrument. It will provide you with the necessary information for a correct use of the instrument, as well as a more precise idea of its versatility. These instruments are in compliance with the directives EN 50081-1 and EN 50082-1. TABLE OF CONTENTS PRELIMINARY EXAMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The instrument should be re-calibrated at least once a month, or when the probe or battery is changed. Note: For more accurate results, it is advisable to use a calibration solution close to the measurement range . See the accessories section on page 23 for a wide selection of conductivity solutions. TEMPERATURE COEFFICIENT 19. 99 mS · Adjust the calibration trimmer (see page 6, #5) on the side of the instrument with the calibration screwdriver until the display shows "12. 88 mS" i. e. the conductivity reading @ 25°C. mS mS · All subsequent measurements will be compensated to 25°C (77°F). If you prefer to standardize the temperature compensation to 20°C (68°F) rather than 25°C (77°F), adjust the trimmer to read "11. 67 mS" (see the conductivity vs. · The calibration is now complete and the instrument is ready for use. 13 14 HI 7 03 COND. PROCEDURE FOR HI 8733 0 Untitled-19 15 16 The instrument should be re-calibrated at least once a month, or when the probe or battery is changed. Note: For more accurate results, it is advisable to use a calibration solution close to the range to be measured. See the accessories section on page 23 for a wide selection of conductivity solutions. · Immerse the TDS probe, making sure that holes are completely submerged, and the ChecktempC in the solution. · Wait for a couple of minutes for thermal equilibrium to be reached. · Tap the probe on the bottom, then shake it while rotating to make sure no air bubbles remain trapped in the sleeve. · Record the temperature of the HI 7032 buffer solution from the ChecktempC (e. g. 18°C). HI °C · Adjust the calibration trimmer (see page 7, #6) on the side of the instrument with the calibration screwdriver until the display shows the TDS reading at 25°C (see the TDS vs. @25°C "1382 mg/L". 703 PROCEDURE FOR HI 8734 0 TEMPERAT URE · Switch the instrument on by pressing ON/OFF. · Adjust the TEMPERATURE knob to display 18°C. ON OFF · All subsequent measurements will be compensated to 25°C (77°F). If you prefer to standardize the temperature compensation to 20°C (68°F) rather than 25°C (77°F), leave the TEMPERATURE knob to 18°C (if the temperature of the solution is 18°C). · The calibration is now complete and the instrument is ready for use. The instrument should be re-calibrated once a month, or when the probe or battery is changed. Note: For more accurate results, it is advisable to use a calibration solution close to the range to be measured. See the accessories section on page 23 for a wide selection of TDS solutions. · Pour sufficient quantity of a conductivity calibration solution (e. g. [. . . ] In such cases, the probe has to be replaced. BATTERY REPLACEMENT When the battery becomes weak the meters will display "V" or an additional blinking decimal point (HI 8733). V When the low battery indicator appears, the battery has only a few hours left. Battery replacement must only take place in a non-hazardous area using an alkaline 9V battery. Slide off the battery compartment cover at the rear of the meter and replace the 9V battery with a new one. Make sure the battery contacts are tight and secure before replacing the cover. HI 933000 9 VOLT BATTERY HI 8033 HI 8633 HI 8733 HI 8734 SLIDE OFF BATTERY SLIDE OFF 21 22 Untitled-19 23 24 SHOCKPROOF RUBBER BOOTS only) ( for H I 933000 only ) These rubber boots are specially made to prolong the life of your instrument and to prevent damage due to accidental bangs and falls. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 933000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 933000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.