User manual HANNA INSTRUMENTS HI 9321

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 9321. We hope that this HANNA INSTRUMENTS HI 9321 user guide will be useful to you.


HANNA INSTRUMENTS HI 9321 : Download the complete user guide (733 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 9321

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 9321 HI 931400 HI 931401 Microprocessor-based Bench pH/mV/°C Meters ins rum pH ns / CFM / CFM CAL pH ca libration Start calibra Select buffer proce dure MEM MR COMM RANG tion Confir m wh 1 value dy Functio n For sto ring dis us sto on play res a ult Select Confir m wh en rea buffer 2 value dy °C en rea Recal l previo For RS pH or HI 93 MIC 1401 pH M ROPROCE ETER SSOR MEM E Sel ect 232 con ORP red dat figurati measu rement ON °C OFF MR °C CAL COMM CFM RANGE www. hannainst. com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Product. It is recommended that you read this instruction manual carefully before using the instrument. This manual will provide you with the necessary information for the correct use of the instrument, as well as a precise idea of its versatility. If you need more technical information, do not hesitate to e-mail us at tech@hannainst. com. [. . . ] Make sure that your meter is switched off and plug the connectors, one into the meter RS232C socket, the other into the serial port of your PC. Note: Cables other than HI 920010 may use a different configuration, in which case, communication between the meter and the PC may not be possible. Excel© Copyright of "Microsoft Co. " Lotus 1-2-3© Copyright of "Lotus Co. " Windows® and Windows Terminal® are registered Trademark of "Microsoft Co. " 17 TROUBLESHOOTING GUIDE Symptoms Problem Solution The meter is slow in The electrode is not Leave the electrode in a storresponding or gives working or the reference age solution after cleaning faulty readings the junction. If problem perjunction is clogged sists, replace the electrode The meter does not Out of order pH elec- Follow the cleaning proceaccept the 2nd buffer trode dure. If this doesn't work solution for calibration replace the electrode The reading drifts Display shows: Defective pH electrode Out of range pH scale Replace the electrode a) Recalibrate b) Make sure the pH sample is in the 0 to 14 range c) Check the electrolyte level and the general state of the pH electrode Display shows: Out of range tempera- Make sure the temperature ture scale is in the 0 to 100°C range and the temperature probe is plugged in Out of range mV scale Electrode not connected Display shows: Display shows: "WRONG 1 " and "WRONG " BUF Erroneous buffer solution Make sure the buffer setting used for offset calibra- is correct and the solution is fresh. Replace the buffer if tion necessary Defective electrode Replace the electrode Erroneous buffer solution Make sure the buffer setting used for slope calibra- is correct and the solution is tion fresh. Replace the buffer if necessary Defective electrode Replace the electrode Display shows: "WRONG 2 " and "WRONG " BUF The meter does not Out of order temperature Replace the probe work with the tem- probe perature probe The meter fails to cali- Out of order pH elec- Replace the electrode brate or gives faulty trode readings 18 ELECTRODE CONDITIONING & MAINTENANCE PREPARATION Remove the protective cap. This is normal with electrodes and they will disappear when rinsed with water. During transport tiny bubbles of air may form inside the glass bulb affecting proper functioning of the electrode. These bubbles can be removed by "shaking down" the electrode as you would do with a glass thermometer. If the bulb and/or junction is dry, soak the electrode in HI 70300 or HI 80300 Storage Solution for at least one hour. 19 For refillable electrodes: If the filling solution (electrolyte) is more than 2½ cm (1") below the fill hole, add HI 7082 or HI 8082 3. 5M KCl Electrolyte Solution for double junction or HI 7071 or HI 8071 3. 5M KCl+AgCl Electrolyte Solution for single junction electrodes. For a faster response, unscrew the fill hole screw during measurements. For AmpHel® electrodes: If the electrode does not respond to pH changes, the battery is run down and the electrode should be replaced. MEASUREMENT Rinse the electrode tip with distilled water. Immerse the tip (bottom 4 cm /1½") in the sample and stir gently for a few seconds. For a faster response and to avoid cross contamination of the samples, rinse the electrode tip with a few drops of the solution to be tested, before taking measurements. STORAGE To minimize clogging and assure a quick response time, the glass bulb and the junction should be kept moist and not allowed to dry out. Replace the solution in the protective cap with a few drops of HI 70300 or HI 80300 Storage Solution or, in its absence, Filling Solution (HI 7071 or HI 8071 for single junction or HI 7082 or HI 8082 for double junction electrodes). Note: NEVER STORE THE ELECTRODE IN DISTILLED OR DEIONIZED WATER. PERIODIC MAINTENANCE Inspect the electrode and the cable. The cable used for connection to the meter must be intact and there must be no points of broken insulation on the cable or cracks on the electrode stem or bulb. For refillable electrodes: Refill the reference chamber with fresh electrolyte (HI 7071 or HI 8071 for single junction or HI 7082 or HI 8082 for double junction electrodes). Follow the Storage Procedure above. AmpHel® is a registered Trademark of "Hanna Instruments" 20 CLEANING PROCEDURE Soak in Hanna HI 7061 or HI 8061 General Cleaning Solution for approximately ½ hour. Removal of films, dirt or deposits on the membrane/junction: - Protein Soak in Hanna HI 7073 or HI 8073 Protein Cleaning Solution for 15 minutes. - Inorganic Soak in Hanna HI 7074 or HI 8074 Inorganic Cleaning Solution for 15 minutes. - Oil/grease Rinse with Hanna HI 7077 or HI 8077 Oil and Fat Cleaning Solution. [. . . ] Use: very high humidity. 12 mm 0. 5" FC 911 110 mm 4. 3" HI 1413B Glass-body, single junction, flat tip, Viscolene, non-refillable, combination pH electrode. Use: surface measurement. 12 mm 0. 5" HI 1413 110 mm 4. 3" Half-cell electrodes: HI 2110B Glass-body, single half-cell pH electrode. Use: general purpose. 9. 5mm DIA 0. 37" 12 mm 0. 5" HI 2110 120 mm 4. 7" HI 5311 Glass-body, Ag/AgCl reference half-cell electrode, double junction, refillable with 4mm plug with 1m (3. 3') cable. Use: general purpose with wide temperature range. 12 mm 0. 5" HI 5311 120 mm 4. 7" Kynar® is registered Trademark of "Pennwalt Corp. " 32 HI 5412 Glass-body, single Calomel reference half-cell electrode, refillable with 4mm plug with 1m (3. 3') cable. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 9321




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 9321 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.