User manual HANNA INSTRUMENTS HI 93104

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 93104. We hope that this HANNA INSTRUMENTS HI 93104 user guide will be useful to you.


HANNA INSTRUMENTS HI 93104 : Download the complete user guide (1085 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 93104

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual MULTIPARAMETER ION SPECIFIC METERS Manufacturers since 1978 These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information for the correct use of the instrument. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. These instruments are in compliance directives EN 50081-1 and EN 50082-1. [. . . ] The reaction between pH and the reagent causes a red tint in the sample. Description TPTZ Reagent Phenol red Quantity 2 packets 5 drops HI 93743 Iron LR & pH REQUIRED REAGENTS Code HI 93746-0 HI 93710-0 Unit Iron LR pH 19 REAGENT SETS HI 93746-01 Reagents for iron LR (100 packets) HI 93746-03 Reagents for iron LR (300 packets) HI 93710-01 Reagents for 100 pH tests HI 93710-03 Reagents for 300 pH tests For other accessories see page 48. MEASUREMENT PROCEDURE · Turn the meter on by pressing ON/OFF. The meter ON will automatically default to the pH measurement OFF mode and pH will appear on the left to warn the user. · Refer to the manual pages below to measure the appropriate parameter and for the required reagents: pH pH MEASUREMENT · See page 46. IRON LR MEASUREMENT · Press SET to select the iron scale. "F" will appear on the LCD; then see page 44. HI 93743 Iron LR & pH 20 HI 93744 pH/Total Hardness/Iron Low Range The HI 93744 meter measures the pH, the Magnesium (Mg), Calcium (Ca) and Total Hardness and the Iron (Fe) content in water and wastewater. SPECIFICATIONS pH Fe Mg Hardness Ca Hardness Total Hardness Resolution pH Fe Hardness Accuracy pH Fe Hardness Typical EMC pH Deviation Fe Hardness Light Source Method Range 5. 9 to 8. 5 0 to 400 µg/L 0. 00 to 2. 00 mg/L 0. 00 to 2. 70 mg/L 0. 00 to 4. 70 mg/L 0. 1 1 µg/L 0. 01 mg/L ±0. 1 ±10 µg/L ±8% of reading ±0. 11 mg/L ±5% of reading ±0. 2 ±1 µg/L ±0. 02 mg/L Light Emitting Diode @ 555 nm For pH, Phenol red method. The reaction between pH and the reagent causes a red tint in the sample. The reaction between iron and the reagent causes a blue tint in the sample. For Hardness, adaptation of the Standard Meth21 HI 93744 Hardness/Iron LR/pH ods for the Examination of Water and Wastewater, 18th edition, Calmagite/colorimetric method. The reaction between hardness and reagents causes a maroon tint in the sample. REQUIRED REAGENTS Code HI 93710-0 HI 93746-0 HI 93719A-0 HI 93719B-0 HI 93719C-0 HI 93719D-0 Unit pH Iron LR Hardness Hardness Hardness Hardness Description Phenol red TPTZ Reagent Ca & Mg indicator Alkali solution EDTA solution EGTA solution Quantity 5 drops 2 packets 0. 5 mL 0. 5 mL 1 drop 1 drop REAGENT SETS HI 93710-01 Reagents for 100 pH tests HI 93710-03 Reagents for 300 pH tests HI 93746-01 Reagents for iron LR (100 packets) HI 93746-03 Reagents for iron LR (300 packets) HI 93719-01 Reagents for 100 hardness tests HI 93719-03 Reagents for 300 hardness tests For other accessories see page 48. MEASUREMENT PROCEDURES ON OFF · Turn the meter on by pressing ON/OFF. · When the LCD displays "- - - -" keep SET pressed until the desired parameter is displayed. SET · Release the key and when the LCD displays "- - -", it is ready. · Refer to the manual pages below to measure the appropriate parameter and for the required reagents: pH MEASUREMENT · "PH" will appear on the LCD; then see page 46. LOW RANGE IRON MEASUREMENT HARDNESS MEASUREMENT · "FE" will appear on the LCD; then see page 44. · "Hrd" will appear on the LCD; then see page 39. HI 93744 Hardness/Iron LR/pH 22 HI 93745 pH/Free & Total Chlorine Total Hardness/Iron Low Range The HI 93745 meter measures the pH, the Magnesium (Mg), Calcium (Ca) and Total Hardness, the Free and Total Chlorine (Cl2) and Iron (Fe) contents in water and wastewater. SPECIFICATIONS Range pH Free Cl2 Total Cl2 Fe Mg Hardness Ca Hardness Total Hardness Resolution pH Cl2 Fe Hardness Accuracy pH Cl2 Fe Hardness Typical EMC pH Deviation Cl2 Fe Hardness 5. 9 to 8. 5 0. 00 to 2. 50 mg/L 0. 00 to 3. 50 mg/L 0 to 400 µg/L 0. 00 to 2. 00 mg/L 0. 00 to 2. 70 mg/L 0. 00 to 4. 70 mg/L 0. 1 0. 01 mg/L 1 µg/L 0. 01 mg/L ±0. 1 ±0. 03 mg/L ±3% of reading ±10 µg/L ±8% of reading ±0. 11 mg/L ±5% of reading ±0. 1 ±0. 01 mg/L ±1 µg/L ±0. 02 mg/L 23 HI 93745 Chlorine/pH/Iron LR/Hardness Light Source Method Light Emitting Diode @ 555 nm For pH, Phenol red method. The reaction between pH and the reagent causes a red tint in the sample. The reaction between chlorine and the reagent causes a pink tint in the sample. The reaction between iron and the reagent causes a blue tint in the sample. For Hardness, adaptation of the Standard Methods for the Examination of Water and Wastewater, 18 t h edition, Calmagite/colorimetric method. The reaction between hardness and reagents causes a maroon tint in the sample. Description Phenol red DPD DPD TPTZ Reagent Ca & Mg indicator Alkali solution EDTA solution EGTA solution DPD1 indicator DPD1 buffer DPD1 indicator DPD1 buffer DPD3 solution Quantity 5 drops 1 packet 1 packet 2 packets 0. 5 mL 0. 5 mL 1 drop 1 drop 3 drops 3 drops 3 drops 3 drops 1 drop REQUIRED REAGENTS Code Unit HI 93710-0 pH HI 93701-0 Free Cl2 HI 93711-0 Total Cl2 HI 93746-0 Iron LR HI 93719A-0 Hardness HI 93719B-0 Hardness HI 93719C-0 Hardness HI 93719D-0 Hardness Liquid version (chlorine): HI 93701A-F Free Cl2 HI 93701B-F Free Cl2 HI 93701A-T Total Cl2 HI 93701B-T Total Cl2 HI 93701-C Total Cl2 REAGENT SETS HI 93710-01 HI 93710-03 HI 93701-01 HI 93701-03 HI 93711-01 HI 93711-03 HI 93701-F Reagents for 100 pH tests Reagents for 300 pH tests Reagents for 100 free chlorine tests Reagents for 300 free chlorine tests Reagents for 100 total chlorine tests Reagents for 300 total chlorine tests Reagents for 300 free chlorine tests (liquid version) 24 HI 93745 Chlorine/pH/Iron LR/Hardness HI 93701-T Reagents for 300 total chlorine tests (liquid version) HI 93719-01 Reagents for 100 hardness tests HI 93719-03 Reagents for 300 hardness tests HI 93746-01 Reagents for iron LR (100 packets) HI 93746-03 Reagents for iron LR (300 packets) For other accessories see page 48. MEASUREMENT PROCEDURES · Turn the meter on by pressing ON/OFF. ON OFF · When the LCD displays "- - - -" keep SET pressed until the desired parameter is displayed. · Release the key and when the LCD displays "- - -", it is ready. SET · Refer to the manual pages below to measure the appropriate parameter and for the required reagents: FREE CHLORINE MEASUREMENT · "Cl F" will appear on the LCD; then see page 34. TOTAL CHLORINE MEASUREMENT · "Cl t" will appear on the LCD; then see page 36. pH MEASUREMENT · "PH" will appear on the LCD; then see page 46. LOW RANGE IRON MEASUREMENT · "FE" will appear on the LCD; then see page 48. HARDNESS MEASUREMENT · "Hrd" will appear on the LCD; then see page 39. 25 HI 93745 Chlorine/pH/Iron LR/Hardness C 101 - PH, CL 2, CYS, I, BR, FE The C 101 meter measures free & total chlorine, cyanuric acid, pH, iodine, bromine and low range iron in water and wastewater. SPECIFICATIONS Range pH Free Cl2 Total Cl2 Cyanuric Acid Iodine Bromine Low Range Iron Resolution pH Free Cl2 Total Cl2 Cyanuric Acid Iodine Bromine Low Range Iron Accuracy pH Free Cl2 Total Cl2 Cyanuric Acid Iodine Bromine Low Range Iron Typical EMC pH Deviation Free Cl2 Total Cl2 Cyanuric Acid 5. 9 to 8. 5 0. 00 to 2. 50 mg/L 0. 00 to 3. 50 mg/L 0 to 80 mg/L 0. 0 to 12. 5 mg/L 0. 00 to 8. 00 mg/L 0 to 400 µg/L (ppb) 0. 1 0. 01 mg/L 0. 01 mg/L 1 mg/L 0. 1 mg/L 0. 01 mg/L 1 µg/L ±0. 1 ±0. 03 mg/L ±3% of reading ±0. 03 mg/L ±3% of reading ±1 mg/L ±15% of reading ±0. 1 mg/L ±5% of reading ±0. 08 mg/L ±3% of reading ±10 µg/L ±8% of reading ±0. 1 ±0. 01 mg/L ±0. 01 mg/L ±1 mg/L 26 C 101 pH/Cl/CYS/I/Br/Fe Iodine Bromine Low Range Iron Light Source Method ±0. 1 mg/L ±0. 01 mg/L ±1 µg/L Light Emitting Diode @ 555 nm For Chlorine, Iodine and Bromine, adaptation of the EPA recommended DPD method 330. 5. Description Phenol red DPD Reagent DPD Reagent DPD Reagent Powder Reagent TPTZ Reagent DPD1 indicator DPD1 buffer DPD1 indicator DPD1 buffer DPD3 solution Quantity 5 drops 1 packet 1 packet 1 packet 1 packet 2 packets 3 drops 3 drops 3 drops 3 drops 1 drop REQUIRED REAGENTS Code Unit HI 93710-0 pH HI 93701-0 Free Cl2 HI 93716-0 Bromine HI 93718-0 Iodine HI 93722-0 Cyanuric Acid HI 93746-0 Iron LR Liquid version (Chlorine): HI 93701A-F Free Cl2 HI 93701B-F Free Cl2 HI 93701A-T Total Cl2 HI 93701B-T Total Cl2 HI 93701-C Total Cl2 REAGENT SET HI 93701-01 Reagents for 100 free chlorine tests HI 93701-03 Reagents for 300 free chlorine tests HI 93701-F Reagents for 300 free Cl2 tests (liquid version) HI 93701-T Reagents for 300 total Cl2 tests (liquid version) HI 93710-01 Reagents for 100 pH tests HI 93710-03 Reagents for 300 pH tests HI 93711-01 Reagents for 100 total chlorine tests HI 93711-03 Reagents for 300 total chlorine tests HI 93716-01 Reagent for 100 bromine tests HI 93716-03 Reagent for 300 bromine tests HI 93718-01 Reagent for 100 iodine tests HI 93718-03 Reagent for 300 iodine tests HI 93722-01 Reagents for 100 cyanuric acid tests HI 93722-03 Reagents for 300 cyanuric acid tests HI 93746-01 Reagents for Iron LR (100 packets) HI 93746-03 Reagents for Iron LR (300 packets) For other accessories see page 48. 27 C 101 pH/Cl/CYS/I/Br/Fe MEASUREMENT PROCEDURES · Turn the meter on by pressing ON/OFF. ON OFF · When the LCD displays "C101" keep SET pressed until the desired parameter is displayed. SET · Release the key and when the LCD displays "- - -", it is ready. · Refer to the manual pages below to measure the appropriate parameter and for the required reagents: FREE CHLORINE MEASUREMENT · "Cl F" will appear on the LCD; then see page 34. TOTAL CHLORINE MEASUREMENT · "Cl t" will appear on the LCD; then see page 36. pH MEASUREMENT · "PH" will appear on the LCD; then see page 46. IODINE MEASUREMENT · "Id" will appear on the LCD; then see page 42. BROMINE MEASUREMENT · "br" will appear on the LCD; then see page 32. CYANURIC ACID MEASUREMENT · "CYS" will appear on the LCD; then see page 38. LOW RANGE IRON MEASUREMENT · "FE" will appear on the LCD; then see page 44. C 101 pH/Cl/CYS/I/Br/Fe 28 C 104 - PH, CL2 AND CYANURIC ACID The C 104 meter measures pH, chlorine (Cl2, free and total) and cyanuric acid content in water and wastewater. SPECIFICATIONS pH Free Cl2 Total Cl2 Cyanuric Acid Resolution pH Cl2 Cyanuric Acid Accuracy pH Cl2 Cyanuric Acid Typical EMC pH Deviation Cl2 Cyanuric Acid Light Source Method Range 5. 9 to 8. 5 0. 00 to 2. 50 mg/L 0. 00 to 3. 50 mg/L 0 to 80 mg/L 0. 1 0. 01 mg/L 1 mg/L ±0. 1 ±0. 03 mg/L ±3% of reading ±1 mg/L ±15% of reading ±0. 1 ±0. 01 mg/L ±1 mg/L Light Emitting Diode @ 555 nm For chlorine, adaptation of the EPA recommended DPD method 330. 5. Description Phenol red DPD 29 REQUIRED REAGENTS Code HI 93710-0 HI 93701-0 Unit pH Free Cl2 Quantity 5 drops 1 packet C 104 pH/Cl/Cyanuric A. HI 93711-0 Total Cl2 HI 93722-0 Cyanuric Acid Liquid version (chlorine): HI 93701A-F Free Chlorine HI 93701B-F Free Chlorine HI 93701A-T Total Chlorine HI 93701B-T Total Chlorine HI 93701-C Total Chlorine DPD Powder Reagent DPD1 indicator DPD1 buffer DPD1 indicator DPD1 buffer DPD3 solution 1 packet 1 packet 3 drops 3 drops 3 drops 3 drops 1 drop REAGENT SETS HI 93701-01 Reagents for 100 free chlorine tests HI 93701-03 Reagents for 300 free chlorine tests HI 93701-F Reagents for 300 free chlorine tests (liquid version) HI 93701-T Reagents for 300 total chlorine tests (liquid version) HI 93710-01 Reagents for 100 pH tests HI 93710-03 Reagents for 300 pH tests HI 93711-01 Reagents for 100 total chlorine tests HI 93711-03 Reagents for 300 total chlorine tests HI 93722-01 Reagents for 100 cyanuric acid tests HI 93722-03 Reagents for 300 cyanuric acid tests For other accessories see page 48. MEASUREMENT PROCEDURE · Turn the meter on by pressing ON/OFF. · When the LCD displays "- - -", it is ready. pH ON OFF pH MEASUREMENTS In order to perform pH measurements, follow the procedure on page 46. CHLORINE MEASUREMENTS · Press SET once to select the chlorine scale. [. . . ] · Remove the cuvet and add 5 drops of the HI 93710 Phenol Red Indicator. Replace the cap and swirl the solution. x5 · Reinsert the cuvet into the instrument. · Press the READ key and "SIP" will appear on the display during measurement. · The instrument directly displays the pH measured value on the Liquid Crystal Display. pH 46 BATTERY REPLACEMENT To prolong battery life, switch your meter off after use. However, the meter has an auto-shut off feature that will turn itself off after 10 minutes of non-use. A "V" on the LCD indicates low voltage and the battery should be replaced. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 93104




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 93104 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.