If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 91610. We hope that this HANNA INSTRUMENTS HI 91610 user guide will be useful to you.
You may also download the following manuals related to this product:
HANNA INSTRUMENTS HI 91610 (928 ko)
HANNA INSTRUMENTS HI 91610 BROCHURE (928 ko)
Manual abstract: user guide HANNA INSTRUMENTS HI 91610
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
HI 9161 - HI 9261 HI 91610
Portable Microprocessor Printing and Logging Thermohygrometers
instru
m en
ts
MICR THE OPROC RMO E HYG SSOR P ROM R ETE INTING R
HI 91 61C
ON/O FF
PAP ER
RAN G %RH E °C -2 5. 0 . . . 95 0. 0 . . + . 0 60. 0
INTV
UP DOW N RAN GE
PRIN T LOG
http://www. hannainst. com
These Instruments are in Compliance with the CE Directives
Dear Customer, Thank you for choosing a Hanna Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with the necessary information for the correct use of the instrument, as well as a precise idea of its versatility. [. . . ] This can be alleviated by applying an external voltage to the unit before replacing the batteries.
RANGE
To view date, press the UP or DOWN keys.
DATE
TO VIEW RH%, TEMPERATURE, TIME, DATE & PRINTING INTERVAL HI 9161 & HI 9261
When the instrument is turned on the display will be in TIME mode. To view RH% on the primary display press the RANGE key.
INTV
TIME
UP
DOWN
HI 91610
To view the time press the TIME key. This also displays the printing/ logging interval.
TIME
INTV
TIME
To view the date, press the UP key when the LCD is displaying time.
RANGE
DATE
UP
16
17
To view RH% on the primary display press RANGE.
RANGE
To view temperature on the primary display when in RH% mode, press RANGE again.
°C
RANGE
meter will print the measurements taken in that moment, and will print with the indicated printing interval thereafter until the ON/OFF key is pressed. The printout provides the following information: a A running log number b A running sample number in that particular log c Date (DD-MM-YY) d Printing interval in minutes e Time (HH. MM) f RH% value g Temperature value
LOG
INTV
If "----" is displayed, it indicates that no probe is connected (or that the probe cable is broken). Note: the RH% value is displayed without any symbol on the primary display. The temperature value is always displayed together with the "°C" or "°F" symbol.
c d e f g
a b
10-01-96 --01-<>
0005M *11. 05 65. 6 RH% 25. 0 °C
0001
PRINTING/RECORDING HI WITH H I 9161 & H I 9261
To print the measured values press PRINT. Each printout provides the following information: a Running sample number b Date (DD-MM-YY) 0001 c Time (HH. MM) d RH% value e Temperature value
<>
When the meter is in recording mode "LOG" is displayed on the secondary LCD with the RH% value on the primary LCD. Press the RANGE key to read the temperature on the primary display.
PRINT
LOG
RANGE
a
10-01-96 *10. 59 65. 6 RH% 25. 0 °C
b c d e
If no keys are pressed after approx. 5 minutes, the meter goes in standby mode to prolong the battery life. Note: If PRINT is pressed while still in recording mode, a printout is produced without affecting the running number.
10-01-96 0005M -- 05 -*11. 51 65. 2 RH% 25. 0 °C
RECORDING AT AN INTERVAL
Set the appropriate logging interval (see pages 12-14). The log number and the recording interval will appear for a few seconds on the secondary display to indicate the operational mode. The
18
PRINT
Printing during recording
LOG
19
TO STOP RECORDING
To exit the recording mode, press the ON/OFF key. The instrument will then make one final exit printout.
10-01-96 --01 -<>
ALT UP DOWN
RANGE
TIME
LOG
0005M *12. 01 65. 1 RH% 25. 0 °C
0006
Press the ALT and PAPER keys at the same time and the "LOG" symbol on display will start to blink.
ON/OFF
PRINT
PAPER
The running log number can be reset by simply removing the batteries.
ALT
UP
PRINTING/LOGGING WITH HI 91610
To print the values shown on the display, press PRINT.
PRINT
After approximately 5 minutes the display will switch itself off but the logging function remains active. Notes: · Once in the logging mode, the interval cannot be changed. Exit the logging mode first (press ALT and LOG together) and then set the new interval.
ALT UP DOWN
TIME
This function can be activated in normal operation mode as well as during logging (and scanning) modes. When in the measurement mode, each printout provides the following information: a Running sample number b Date (DD-MM-YY) 15-01-96 0001 *11. 20 c Time (HH. MM) 65. 6 RH% d RH% value 25. 0 °C e Temperature value
<>
RANGE
TIME
LOG
a b c d e
· If the PRINT key is pressed while in logging mode, a printout is produced without affecting the running sample number.
PRINT
SAMPLE NUMBER
During logging it is possible to know the running sample number. Press the LOG key twice and the display will show the running number in the current log together with sample number symbol "Sn".
LOGGING MODE WITHOUT PRINTING
This function is particularly useful when measurements have to be taken continuously even in the absence of an operator over a long period of time. The current log number and remaining page numbers will appear for a few seconds on the display to indicate the correct operational mode. The printer will print a complete set of data and the "LOG" symbol will appear on the secondary LCD.
20
2x
LOG
LOG
LOGGING MODE WITH PRINTING
This function is useful in a variety of applications from unsupervised monitoring to satisfying regulatory requirements. In addition to the printouts, the measurements are also stored into the memory.
21
Press the ALT and LOG key simultaneously to enter the logging mode. The current log number and the remaining page numbers will appear for a few seconds on the display to indicate the correct operational mode. The printer will print a complete set of data and the "LOG" symbol will appear on the secondary LCD.
ALT
UP
DOWN
LOG
RANGE
TIME
LOG
If no key is pressed, the display goes blank after about 5 minutes and comes back on only to print at the next logging interval. [. . . ] HI 9161, HI 9261 and HI 91610 can also be used with other adapters supplying a 12VDC output. In this case, remember to check the correct polarity of your adapter before connecting it to the meter.
32
33
ACCESSORIES
R. H. PROBES
Hanna Instruments Relative Humidity probes use a high-tech ThinFilm Polymer Capacitance humidity sensor. probe with sintered protective cap and 2 m (7') cable HI 70606/5 R. H. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 91610
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 91610 will begin.