User manual HANNA INSTRUMENTS HI 9065

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 9065. We hope that this HANNA INSTRUMENTS HI 9065 user guide will be useful to you.


HANNA INSTRUMENTS HI 9065 : Download the complete user guide (520 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 9065

Detailed instructions for use are in the User's Guide.

[. . . ] 6 CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 BATTERY REPLACEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Note: HI 9065 can be used with just one probe (RH or temperature) at a time. TEMPERATURE MEASUREMENTS (HI 9065 ONLY) Connect the temperature probe (HI 765 series, see "Accessories") to the socket on the top of the meter and the unit will automatically display the temperature reading. Note: HI 9065 can be used with just one probe (RH or temperature) at a time. Press the "°C" key and the temperature value is displayed in degrees Centigrade with the "°C" symbol. °C °C The same reading in degrees Fahrenheit is shown if the "°F" key is pressed. RH (RELATIVE HUMIDITY) MEASUREMENTS Turn the meter on by pressing ON/OFF. The "H" symbol on the display indicates RH measurement mode. °F ON/OFF For any problem in taking measurements, please contact your dealer or the nearest HANNA Customer Service Department. H RH HOLD FUNCTION The reading HOLD function is activated by the HOLD key. The measured value is frozen on the display when this function key is pressed. "S" is S displayed to indicate that the reading is also stored. Press the same key again to retirn to normal mode. HOLD · For reliable measurements, the end of the humidity detector should be exposed to a current of air moving at 0. 5 m (20") per second or more. · In the absence of air movement, the response can be accelerated by moving the probe. · The probe sensor must never come into contact with water or other liquids. If this should happen, or if condensation causes drops to form on the surface of the humidity sensor, turn off the instrument and wait until they have evaporated completely. To accelerate the evaporation process, expose the humidity sensor to a current of air. DISPLAY CODES °C temperature readings in degrees Centigrade (HI 9065 only) H indicate RH (Relative Humidity) readings S indicate that displayed reading has been stored 6 7 CALIBRATION All HANNA hygrometers have been precalibrated at the factory. HANNA instruments® uses state-of-the-art thermal humidity chambers for this purpose. It is generally recommended to have all hygrometers recalibrated at least once a year. For an accurate annual recalibration, contact the nearest Hanna Service Center. You can also check the status of your hygrometer and perform a quick RH recalibration (with an accuracy of ±5%) by using the HANNA calibration chamber HI 7101. Li Cl 11. 1% Na Cl 75. 4% H 2 O · Pour approximately 12 cc of distilled water into the other chamber marked "RH 75. 4%". Li Cl 11. 1% Na Cl 75. 4% CALIBRATION KIT 12 cc · Add all the content of the HI 7121 bottle containing NaCl while continuously shaking the container to avoid the formation of lumps. The calibration kit needs approximately 4 hours for stabilization. Na Cl Li Cl 11. 1% Na Cl 75. 4% CALIBRATION KIT CALIBRATION KIT 12 9 3 6 The kit is composed of two thermally isolated chambers, both equipped with a threaded cap and three bottles containing the appropriate precalibrated saturated salts to produce a known RH value. 4h CALIBRATION PROCEDURE · Bring the calibration kit to a temperature of approximately 20°C. · Remove the cap from the "RH 11. 1%" chamber containing the LiCl solution and insert the probe paying attention not to dip it into the liquid. · Remove the adhesive sticker which covers the calibration trimmer access holes. Li Cl 11. 1% Na Cl 75. 4% PREPARING THE CALIBRATION SOLUTIONS · Pour approximately 26 cc of distilled water into a glass container. [. . . ] · Leaving the probe in the "RH 75. 4%" chamber, adjust the low humidity trimmer until the display shows 75. 4%. H · The relative humidity calibration is now complete. 10 11 ACCESSORIES HI 70605/2 RH probe with built-in temperature sensor, 2 m (6. 6') cable and perforated cap (for HI 9065) HI 70605/5 RH probe with built-in temperature sensor, 5 m (16. 5') cable and perforated cap (for HI 9065) HI 70607/2 RH probe with 2 m (6. 6') cable and sintered cap (for HI 9065) HI 70607/5 RH probe with 5 m (16. 5') cable and sintered cap (for HI 9065) HI 70608/2 RH probe with 2 m (6. 6') cable (for HI 9064) HI 70608/5 RH probe with 5 m (16. 5') cable (for HI 9064) HI 7101 Calibration chamber for probes with perforated cap, complete with O-ring and precalibrated saturated salts HI7111/P Spare saturation LiCl salts for low humidity calibration (15 g, 6 pcs) HI7121/P Spare saturation NaCl salts for high humidity calibration (33 g, 6 pcs) HI 721317 Rugged carrying case WARRANTY All Hanna Instruments meters are guaranteed for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. Damage due to accident, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 9065




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 9065 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.