Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information for correct operation. If you need additional technical information, do not hesitate to email us at tech@hannainst. com. [. . . ] First obtain a Returned Goods Authorization number from the Customer Service department, then return the instrument with the Authorization # included along with shipment costs prepaid. If the repair is not covered by the warranty, you will be notified of the charges. When shipping any instrument, make sure it is properly packaged for complete protection. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc. , Woonsocket, Rhode Island, 02895 , USA.
Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice.
GENERAL DESCRIPTION
HI 8757 and HI 8758 are Hanna microprocessor-based, Ktype thermocouple thermometers specially dedicated to education. These meters perform measurements either in °C (HI 8757) or °F (HI 8758) in a wide range of temperature; readings are linearized for increased accuracy, and resolution is automatically switched from 0. 1° to 1° for temperatures above 200°C (400°F). These thermometers are also provided with battery level indication at start-up, and with the BEPS feature (Battery Error Prevention System), which automatically switches the instrument off when the battery is discharged to avoid erroneous readings due to low battery level. Each meter comes complete with a 9V battery and instruction manual.
HI 8758
SPECIFICATIONS HI 8758 Range (*) -58. 0 to 399. 9°F / 400 to 2462°F Resolution 0. 1°F (-58. 0 to 399. 9°F) (Autoranging) 1°F (400 to 2462°F) Accuracy ±0. 5% F. S. (@20°C/68°F) excluding probe error EMC Typical ±1ºF Deviation with HI766 K-thermocouple probe Display 4-digit LCD Battery Type 1 x 9V (IEC 6LR61) battery Life approx. 500 hours of continuous use Probe K-type thermocouple (see "Accessories") Environment -10 to 50ºC (14 to 122ºF); max. 95% RH non-condensing Dimensions 180 x 83 x 40 mm (7. 1x3. 3x1. 6") Weight 226 g (8 oz. ) meter only (*) Range may be limited by probe.
1) 2) 3) 4)
LCD display Rotary switch OFF mode Measurement mode
OPERATIONAL GUIDE
BATTERY REPLACEMENT
ACCESSORIES
K-TYPE THERMOCOUPLE PROBES
with integral handle, 1 m (3. 3') cable & mini-connector: HI 766A Roller surface probe, max 320°C/600°F HI 766B Surface probe, max 650°C/1200°F HI 766B1 90º Surface probe, max 450°C/840°F HI 766B2 Spring-loaded, surface probe, max 900°C/1650°F HI 766B3 Spring-loaded, small surface probe with insulated shaft, max 200°C/390°F HI 766C Penetration probe, max 900°C/1650°F HI 766C1 Ultra-fast Penetration probe, max 300°C/ 570°F HI 766D Air probe, max 300°C/570°F HI 766E1 General purpose probe, max 900°C/1650°F HI 766E2 General purpose probe, max 900°C/1650°F HI 766F High temperature, flexible wire probe without handle, max 1100°C/2000°F HI 766F1 Flexible wire probe without handle, max 480°C/ 900°F HI 766TR1 Penetration probe, max 250°C/482°F HI 766TR2 Penetration long probe, max 250°C/482°F HI 766TV1 Pipe clamp probe, max 200°C/390°F with detachable handle & mini-connector (to be used in conjunction with the HI 766HD probe handle): HI 766PA Roller surface probe, max 320°C/600°F HI 766PB Surface probe, max 650°C/1200°F HI 766PC Penetration probe, max 900°C/1650°F HI 766PD Air probe, max 300°C/570°F HI 766PE1 General purpose probe, max 900°C/1650°F HI 766PE2 General purpose probe, max 900°C/1650°F grill surface probe: HI 766B4 Grill surface probe with 70 cm (27. 6'') cable (protected with stainless steel jacket), max 250°C/482°F HI 7664B4S Spare stainless steel sensor for HI766B4 probe
CE DECLARATION OF CONFORMITY
Remove the battery cover on the back of the thermometer. Unwrap the supplied 9V battery, connect it to the battery clip and reattach the cover. Connect the temperature probe to the connector on the top of the meter. To switch ON, turn the rotary knob to the ºC or ºF position (depending on the model). The meter displays the percentage indication of the remaining battery life for a few seconds, and then enters measurement mode. If a temperature probe is plugged in, the meter displays the measured temperature either in °C (HI 8757) or °F (HI 8758), automatically switching to the resolution suitable to the temperature range; i. e. If no probe is plugged in, or if reading is over-range, the display shows flashing dashes. [. . . ] To avoid damage or burns, do not perform any measurement in microwave ovens.
FACTORY RECALIBRATION
All Hanna thermometers have been accurately pre-calibrated at the factory. It is generally recommended to have all thermometers recalibrated at least once a year. For an accurate annual recalibration, contact your dealer or the nearest Hanna Service Center.
OTHER ACCESSORIES
HI 710002 HI 710009/10 HI 710031 HI 721310 HI 766EX HI 766HD Soft carrying case Blue/Orange rubber boot Hard carrying case 9V Battery (10 pcs) Extension cable for K-type probes Rugged thermocouple probe handle with 1m (3. 3') cable fitted with mini-connector
ISTR8757