User manual HANNA INSTRUMENTS HI 83741

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 83741. We hope that this HANNA INSTRUMENTS HI 83741 user guide will be useful to you.


HANNA INSTRUMENTS HI 83741 : Download the complete user guide (929 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 83741

Detailed instructions for use are in the User's Guide.

[. . . ] 8 GUIDE TO DISPLAY CODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 GENERAL TIPS FOR AN ACCURATE MEASUREMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 MEASUREMENT PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 BATTERIES REPLACEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Operation of these instruments may cause unacceptable interferences to other electronic equipments, this requiring the operator to take all necessary steps to correct interferences. Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance. To avoid damages or burns, do not put the instrument in microwave ovens. For yours and the instrument safety do not use or store the instrument in hazardous environments. WARRANTY HI 83741 is warranted for two years against defects in workmanship and materials when used for its intended purpose and maintained according to the instructions. Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service Department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. 4 17 BATTERIES REPLACEMENT Battery replacement must only take place in a nonhazardous area. The blinking " " will appear when the batteries power gets low. When batteries are completely discharged, "0% bAtt" will appear and after two seconds the instrument is switched off. Remove the battery cover from the bottom of the instrument and change the old batteries with 4 fresh 1. 5V batteries, paying attention to the correct polarity. Replace the cover. SPECIFICATIONS Range Resolution Precision Light Source Light Detector Method Environment Battery Type Auto-Shut off Dimensions Weight REQUIRED REAGENTS Code HI 83741A-0 HI 83741B-0 HI 83742-0 0. 0-15. 0 mg/L 0. 1 mg/L SD ±0. 4 mg/L @ 4. 0 mg/L Tungsten lamp with narrow band interference filter @ 560 nm Silicon Photocell The reaction between Iron and the reagents causes a purple tint in the sample. 0 to 50°C (32 to 122°F); max 95% RH non-condensing 4 x 1, 5 volt AA batteries / 12 to 20 VDC through voltage adapter After 15' of non-use in measurement mode. 225 x 85 x 80 mm (8. 7 x 3. 3 x 3. 1") 500 g (17, 6 oz. ) Description Iron Reagent A Iron Reagent B Wine solvent-1 Quantity/test 1 packet 1 packet 9 mL ACCESSORIES REAGENT SETS HI 83741-20 Iron reagents set for wine (20 tests) OTHER ACCESSORIES HI 740027P 1. 5V AA batteries (10 pcs) HI 731318 Tissue for wiping cuvets (4 pcs) HI 731321 Glass cuvets (4 pcs) HI 731325W Caps for cuvets (4 pcs) HI 93703-50 Cuvets cleaning solution (230 mL) HI 731341 1000 µL automatic pipette HI 731351 Plastic tips for 1000 µL automatic pipette (25 pcs) PRECISION AND ACCURACY Precision is how closely repeated measurements agree with each other. Accuracy is defined as the nearness of a test result to the true value. Although good precision suggests good accuracy, precise results can be inaccurate. In a laboratory using a standard solution of 4. 0 mg/L iron and a representative lot of reagent, an operator obtained with a single instrument a standard deviation of 0. 4 mg/L. 5 16 PRINCIPLE OF OPERATION Absorption of Light is a typical phenomenon of interaction between electromagnetic radiation and matter. When a light beam crosses a substance, some of the radiation may be absorbed by atoms, molecules or crystal lattices. [. . . ] Contact your dealer or the nearest Hanna Customer Service Center. a) on zero reading: Hanna automatic pipette "Light high": there is too much light to perform a measurement. "Light low": there is not enough light to perform a measurement. Please dilute the sample five times (see "General tips for an accurate measurement", page 12). "No Light": the lamp is not working because of a malfunction. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 83741




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 83741 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.