User manual HANNA INSTRUMENTS HI 983329-0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 983329-0. We hope that this HANNA INSTRUMENTS HI 983329-0 user guide will be useful to you.


HANNA INSTRUMENTS HI 983329-0 : Download the complete user guide (330 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 983329-0

Detailed instructions for use are in the User's Guide.

[. . . ] These instruments are in compliance with the directives. SPECIFICATIONS Range 0 to 999 ppm Resolution 1 ppm Accuracy (@ 20°C) ±2% f. s. Setpoint Adjustable through multiturn trimmer Alarm Condition LED ON and alarm contact closed when TDS value is higher than setpoint Alarm Output 2-contact relay, no fuse protected. Compensation Automatic from 5 to 50°C (41 to 122°F) with ß=2% TDS Conversion Factor 0. 5 Calibration Manual, at one point through trimmer Calibration Solution HI 7031 (1413 µS/cm) Power supply: External HI983329-0 12VDC HI98332900 12 VDC isolated inside with DC/DC converter HI983329-1 115/230 VAC; 50/60Hz Dimensions 79 x 49 x 95 mm (3. 1 x 1. 9 x 3. 7") Weight: HI983329-0, HI98332900 HI983329-1 140 g (4. 96 oz) 250 g (8. 85 oz) HI 983329 CE DECLARATION OF CONFORMITY PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully. If any damage has occurred during shipment, immediately notify your Dealer or the nearest Hanna Customer Service Center. [. . . ] All the meters automatically compensate for the temperature variation. Measurements are highly accurate and the meters can be calibrated at one point. Power supply, wiring and selection are made via the plugin terminal blocks on the rear panel. LED indicators on the front panel identify whether the controller is in set or measurement mode, and if alarm is active. Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential areas could cause unacceptable interferences to radio and TV equipment. The metal band at the end of the probe is sensitive to electrostatic discharges. During operation, ESD wrist straps should be worn to avoid possible damage to the probe by electrostatic discharges. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. To avoid electrical shock, do not use these instruments when voltage at the measurement surface exceeds 24 VAC or 60 VDC. To avoid damage or burns, do not perform any measurement in microwave ovens. ISTR983329R5 12/01 Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. http://www. hannainst. com FUNCTIONAL DESCRIPTION FRONT PANEL Keypad SET MEAS To display setpoint To display measurement 3. Probe Connection: follow the above diagram and connect the colored wires of probe cable as indicated. It is recommended to connect the shield (P5) to avoid any interference. OPERATIONAL GUIDE POWER CONNECTION HI 983329-0 and HI 98332900 Connect a 2-wire power cable to the terminal strip while paying attention to the correct positive and negative contacts (12 VDC). HI 983329-1 Connect a 3-wire power cable to the terminal strip while paying attention to the correct earth, neutral and line contacts (115/230 VAC). Notes: · All external cables connected to the rear panel should end with wire lugs. · It is recommended to cover the unused terminals with insulating tape. ALARM CONTACT Use this contact (maximum 5A, 240VAC, 30VDC) for connection to an alarm or dosing system. OPERATING THE METER All operations are via the front panel keys and trimmers. "SET" and "MEAS" LEDs light up to indicate which is the operating function. Make sure that the meter is calibrated and the Setpoint is properly selected before performing any measurement. Install the probe in the fittings or immerse it in the solution to be monitored, while making sure that metal pins are completely submerged. [. . . ] · If a more thorough cleaning is required, brush the metal pins with very fine sandpaper. · After cleaning, rinse the probe with tap water and recalibrate the meter. · When not in use, clean the probe before storing it away. Side view of the panel-mounted unit Supplied adjustable location brackets allow the controller to slide into the cutout and will hold the unit securely in place. 95mm (3. 74") is the minimum amount of space required to install the controller. 0. 25/4mm 0. 01/0. 160" ADJUSTABLE LOCATION BRACKET 79mm 3. 11" 76mm 3" 95mm MIN 3. 74" Panel-mounted unit assembling view HI 740146 230 VAC L1: Positive 115 VAC L2: Negative ----Neutral L3: ----Protection Earth L4: Note: Note: the power input is internally protected by a 400 mA fuse 2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 983329-0




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 983329-0 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.