User manual HANNA INSTRUMENTS HI 983313-0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 983313-0. We hope that this HANNA INSTRUMENTS HI 983313-0 user guide will be useful to you.


HANNA INSTRUMENTS HI 983313-0 : Download the complete user guide (371 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 983313-0

Detailed instructions for use are in the User's Guide.

[. . . ] These instruments are in compliance with the directives. SPECIFICATIONS Range 0 to 1999 µS/cm Resolution 1 µS/cm Accuracy (@ 20°C) ±2% f. s. Setpoint Adjustable through multiturn trimmer Alarm Condition LED ON and alarm contact closed when measured EC value is higher than setpoint Alarm Output 2-contact relay, no fuse protected. 5A, 240 VAC, 30 VDC Probe HI 7634-00 EC/TDS probe Temp. Compensation Automatic from 5 to 50°C (41 to 122°F); ß=2%/ºC Calibration Manual, at one point through trimmer Calibration Solution HI 7031 (1413 µS/cm) Power supply: External HI 983313-0 12 VDC HI 983313-1 115/230 VAC; 50/60Hz Dimensions Weight: HI 983313-0 HI 983313-1 79 x 49 x 95 mm (3. 1 x 1. 9 x 3. 7") 140 g (4. 96 oz) 250 g (8. 85 oz) CE DECLARATION OF CONFORMITY Panel-Mounted EC Indicators & Controllers PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully. If any damage has occurred during shipment, immediately notify your Dealer or the nearest Hanna Customer Service Center. [. . . ] Measurements are highly accurate and the meters can be calibrated at one point. Power supply, wiring and selection are made via the plugin terminal blocks on the rear panel. LED indicators on the front panel identify whether the controller is in set or measurement mode and if alarm is active. Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential areas could cause unacceptable interferences to radio and TV equipment. The metal band at the end of the probe is sensitive to electrostatic discharges. During operation, ESD wrist straps should be worn to avoid possible damage to the probe by electrostatic discharges. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. To avoid electrical shock, do not use these instruments when voltage at the measurement surface exceeds 24 VAC or 60 VDC. To avoid damage or burns, do not perform any measurement in microwave ovens. ISTR983313R5 12/01 Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. http://www. hannainst. com FUNCTIONAL DESCRIPTION FRONT PANEL Keypad SET MEAS HI 983313 EC CONTROLLER µS 0 . . . 1999 µS ALARM 3. Probe Connection: follow the above diagram and connect the colored wires of probe cable as indicated. It is recommended to connect the shield (P5) to avoid any interference. OPERATIONAL GUIDE POWER CONNECTION HI 983313-0 Connect a 2-wire power cable to the terminal strip while paying attention to the correct positive and negative polarities (12 VDC). HI 983313-1 Connect a 3-wire power cable to the terminal strip while paying attention to the correct earth, neutral and line contacts (115/230 VAC). ALARM CONTACT Use this contact (maximum 5A, 240VAC, 30VDC) for connection to an alarm or dosing system. Notes: · All external cables connected to the rear panel should end with wire lugs. · It is recommended to cover the unused terminals with insulating tape. OPERATING THE METER All operations can be controlled via front panel keys and trimmers. "SET" and "MEAS" LEDs light up to indicate which is the operating function. Make sure that the meter is calibrated and the Setpoint is properly selected before performing any measurement. [. . . ] Power Supply: HI 983313-0 12 VDC L1: L2: L3: L4: Positive Negative ------HI 983313-1 115/230 VAC 230 VAC 115 VAC Neutral Protection Earth Panel-mounted unit assembling view HI 740146 PROBE MAINTENANCE To improve probe performance and prolong its life, it is recommended to clean it regularly. · Immerse the tip of the probe in HI 7061 Cleaning Solution at least for one hour. · If a more thorough cleaning is required, brush the metal pins with very fine sandpaper. · After cleaning, rinse the probe with tap water and recalibrate the meter. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 983313-0




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 983313-0 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.