User manual HANNA INSTRUMENTS HI 98113

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98113. We hope that this HANNA INSTRUMENTS HI 98113 user guide will be useful to you.


HANNA INSTRUMENTS HI 98113 : Download the complete user guide (29 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 98113 (122 ko)
   HANNA INSTRUMENTS HI 98113 BROCHURE (122 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 98113

Detailed instructions for use are in the User's Guide.

[. . . ] PICCOLO PLUS (ATC pH/°C meter) This meter is in compliance with the CE directives EN 50081-1 and EN 50082-1 Operating Instructions: · Connect the electrode to the meter (both the printings on the body and on the electrode facing upwards, see Fig. Turn the meter on by the OFF/pH/°C switch and select the pH position. [. . . ] · Dual point calibration: dip the electrode into HI 7007S buffer solution (pH 7. 01 @ 25ºC) and adjust the reading by the OFFSET calibration trimmer to the pH value corresponding to the buffer solution temperature. Dip the electrode into HI 7004S buffer solution (pH 4. 01 @ 25ºC) or HI7010 (pH 10. 01 @ 25ºC) and adjust the reading by the SLOPE calibration trimmer to the pH value corresponding to the buffer solution temperature (see Fig. Maintenance: · If the electrode remains dry for a long period, before taking any measurement or calibrating, it is necessary to reactivate it by dipping into HI 70300 solution for about 4 hours. The electrode should be cleaned after use and stored covered by the cap with some HI70300 inside. · Solutions available for the calibration, the maintenance, the storage and the cleaning of the electrode: · HI 774P Calibration kit (pH 4. 01 & 7. 01 @ 25°C, 30 mL each) · HI 7061 General cleaning solution (soak for 30 min. ) · HI777P Calibration kit (pH 7. 01 @ 25°C, 2 x 30 mL) · HI 7073 Protein cleaning solution (soak for 15 min. ) · HI7710P Calibration kit (pH 7. 01 & 10. 01 @ 25°C, 30 mL each) · HI 7074 Inorganic cleaning solution (soak for 15 min) · HI 70300 Storage solution · HI 7077 Oil and fat cleaning solution (soak several times with clean solution) Recommendations for Users: Before using this product, make sure that it is entirely suitable for the environment in which it is to be used. Operation of this instrument in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences. The glass bulb at the end of the electrode is sensitive to electrostatic discharges. During operation, ESD wrist straps should be worn to avoid possible damage to the electrode by electrostatic discharges. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. To avoid electrical shock, do not use this instrument when voltages at the measurement surface exceed 24VAC or 60VDC. [. . . ] 2 pH 4. 01, pH 10. 01 CALIBRATION (SLOPE) HI 1295 Amplified Electrode PICCOLO plus °C - Fig. 4 ins rum n es LOOSEN SCREW BATTERIES HI 1 Am 295 p Ele lified ctro de PIC C plus OLO pH OFF pH °C pH 7. 01 CALIBRATION (OFFSET) pH 4. 01 @ 25°C pH 7. 01 @ 25°C Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98113




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 98113 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.