User manual HANNA INSTRUMENTS HI 93754FG

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 93754FG. We hope that this HANNA INSTRUMENTS HI 93754FG user guide will be useful to you.


HANNA INSTRUMENTS HI 93754FG : Download the complete user guide (171 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 93754FG

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual Method Reagents are in accordance with ISO 15705:2002 method. This method covers the determination of COD in surface water, domestic and industrial wastes. [. . . ] For colorimetric determination of COD, follow the procedure described in the Photometer Instruction Manual*. * Note: for best results in readings use the Hanna equipment: C9800 Reactor and C99 or C214 Photometers. INTERFERENCES: chlorides >1000 mg/L (ppm) Samples with higher chloride concentration should be diluted. COD Chemical Oxygen Demand ISO Reagents Instructions Before starting to use these reagent kits it is important to read carefully this manual and the Health & Safety Data Sheet (HSDS). For sample digestion use a block heater reactor with holes to accommodate digestion vials. Do not use an oven or microwave because leaking samples can generate a corrosive and possibly explosive atmosphere. Note: the reagent is light sensitive, thus store the unused vials in their container and in a refrigerator if possible. Using a Class A glass pipette, add 2 ml of sample to a HI 93754F-25 vial for low range or to a HI 93754G-25 vial for medium range, while keeping the vial at a 45degree angle. sample www. hannainst. com Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully before using the reagent. This manual will provide you with the necessary information for the correct use of the reagents. If you need additional information, do not hesitate to mail us at tech@hannainst. com. Health and Safety Note: for an accurate measurement, run a blank with each set of samples and use the same box of reagents for blank and samples. Wipe the outside of the vials with the HI 731318 or a lint-free cloth and insert the vials into the preheated reactor*. [. . . ] Each kit is supplied complete with: ·COD test tubes (25 pcs); ·Instruction Manual. Note: save all packing material, any defective item must be returned in its original packing. General Description Two reagent kits are available, according to different ISO COD ranges: ·HI 93754F-25 LR: COD - ISO Reagent LR ·HI 93754G-25 MR: COD - ISO Reagent MR Range 0-150 mg/L 0-1000 mg/L Reagent code HI 93754F-25 HI 93754G-25 Sample q. ty 2. 0 mL 2. 0 mL Accessories C 9800-01 C 9800-02 C 99 C214 HI 740142 HI 740143 HI 740216 HI 740217 Hanna Reactor (115 VAC) Hanna Reactor (230 VAC) Hanna Photometer (for Laboratories) Hanna Photometer (for Wastewater Treatment Application) 1 mL graduated syringe 1 mL graduated syringe (6 pcs) Test tube cooling rack (25 holes) Laboratory bench safety shield Each kit contains 25 ready-to-use vials with premeasured reagents: just add sample to the vial and tightly cap it before digestion. SISTCODISO 12/03 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 93754FG




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 93754FG will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.